Module spare parts 1C31129G03
- xiamen
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 1 days
You May Like
Product Details
Brand Name | GE | Model Number | 1C31129G03 |
Product Description
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
1C31129G03 |
2. Select START VENTILATION > Continue. 3. Use the quick key to set FiO2 to 50%. ? Ventilator FiO2 alarms are not active until 60 seconds after an FiO2 change. 4. Select Alarm Setup and set the FiO2 low alarm limit to 30 and the FiO2 high alarm limit to 40. ? Verify the high priority FiO2 high priority alarm sounds. ? Verify the FiO2 high alarm shows with a red background in the alarm bar. ? Verify the display unit alarm light flashes red. 5. Select Alarm Setup and set the FiO2 low alarm limit to 44 and the FiO2 high alarm limit to 56. ? Verify the FiO2 high alarm no longer sounds. ? Verify the FiO2 high alarm shows with a grey background in the alarm bar. ? Verify the display unit alarm light no longer flashes. Low EtO2 alarm test This test requires an installed and warmed-up airway module with O2 monitoring capabilities. 1. Set the vent mode to A/C VC. 2. Select START VENTILATION > Continue. 3. Use the quick key to set FiO2 to 50%. ? Module EtO2 alarms are not active until 90 seconds after an FiO2 change. 4. Select Alarm Setup and set the EtO2 high alarm limit to 70 and the EtO2 low alarm limit to 60. ? Verify the medium priority EtO2 low alarm sounds. ? Verify the EtO2 low alarm shows with yellow background in the alarm bar. ? Verify the display unit alarm light flashes yellow. 5. Select Alarm Setup and set the EtO2 high and low limits to Off. ? Verify the EtO2 low alarm no longer sounds. ? Verify the EtO2 low alarm shows with a grey background in the alarm bar. ? Verify the display unit alarm light no longer flashes. 8 Alarms and troubleshooting 2065490-001 8-29 High EtO2 alarm test This test requires an installed and warmed-up airway module with O2 monitoring capabilities. 1. Set the vent mode to A/C VC. 2. Select START VENTILATION. ? Module EtO2 alarms are not active until 90 seconds after a FiO2 change. 3. Use the quick key to set FiO2 to 50%. 4. Select Alarm Setup and set the EtO2 low alarm limit to 30 and the ETO2 high alarm limit to 40. ? Verify the medium priority EtO2 high alarm sounds. ? Verify the EtO2 high alarm shows with a yellow background in the alarm bar. ? Verify the display unit alarm light flashes yellow. 5. Select Alarm Setup and set the EtO2 low and EtO2 high alarm limits to Off. ? Verify the EtO2 high alarm no longer sounds. ? Verify the EtO2 high alarm shows with a grey background in the alarm bar. ? Verify the display unit alarm light no longer flashes. Low EtCO2 alarm test This test requires an installed and warmed-up airway module with CO2 monitoring capabilities. 1. Set the vent mode to A/C VC. 2. Select START VENTILATION > Continue. 3. Add CO2 into the inspiratory limb to get an EtCO2 value between 5% and 10%. 4. Select Alarm Setup and set the EtCO2 low alarm limit to 12 and the EtCO2 high alarm limit to 15. ? Verify the high priority EtCO2 low alarm sounds. ? Verify the EtCO2 low alarm shows with a red background in the alarm bar. ? Verify the display unit alarm light flashes red
Contact Us
- Xiamen xiongba e-commerce Co., Ltd
Product Categories
ABB | EPRO | PROSOFT | NI |
REXROTH | Schneider | Miscellaneous brand | EMERSON |
SEW | SIEMENS | GE | SST |
A-B | TRICONEX | WATLOW | WOODWARD |
YAMATAKE | YOKOGAWA | HONEYWEL | BENTLY |
FOXBORO | FSC | ENTERASYS | HIMA |
TRIPLEX |
New Products
-
Module spare parts 1C31219G01
-
Module spare parts 1C31222G01
-
Module spare parts 1TGE120021R0010
-
Module spare parts 200-510-017-017 200-510-111-013
-
Module spare parts 200-566-000-012 200-566-101-012
-
Module spare parts 200-595-002-011
-
Module spare parts 216AB61 HESG324013R0100 HESG435572P1
-
Module spare parts 216DB61 HESG324063R0100 HESG216882A
-
Module spare parts 216EA61b HESG324015R1 KHESG324258R3I HESG448230R1
-
Module spare parts 216EA62 1MRB178066R1E 1MRB150083R1E 1MRB300162R0008
-
Module spare parts 216NG63A HESG441635R1 HESG216877K
-
Module spare parts 216VC62A
Popular Searches
Recommended Products
- Allen Bradley 80190-220-01-R
- Allen Bradley 80173-006-01
- Allen Bradley 80026-096-01-R
- Allen Bradley 81001-956-53-R
- Pioneer Magnetics PM3398B-6-1-3-E
- Absopulse MIM105-Q6949?80026-096-01
- GE DS215UCVBG3AJ
- ABB 216VC62A?HESG324442R112?HESG324442R13/C
- ABB 1TGE120021R0010
- ABB 3BHE041343R0102?PCD530?A102
- GE IS200WETAH1ADC
- GE IS200WETAH1AHC
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile