RF522 3BSE000743R1
- 167 Piece / Pieces per Month
- T/T
- 1 days
You May Like
Product Details
Brand Name | ABB | Place of Origin | China | |
Model Number | RF522 3BSE000743R1 |
Product Description
Brand: ABB
Type: RF522 3BSE000743R1
Origin: the Swiss
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts of our products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
Remote EXTR/ADM Setpoint The Extr/Adm control setpoint can be remotely positioned by an analog input (if programmed). The Remote Extr/Adm Setpoint input can be enabled by pressing the front panel YES key from the Remote Extr/Adm Status screen (screen 4), closing the Remote Extr/Adm Setpoint Enable/Disable contact (if programmed), or selecting Remote Extr/Adm Enable from either Modbus communications link.
Remote Extr/Adm Setpoint input is disabled by pressing the front panel NO key from the Remote Extr/Adm Status screen (screen 4), opening the Remote Extr/Adm Enable/Disable contact (if programmed), or selecting Remote Extr/Adm Disable from either Modbus communications link. See Table 5-14 for all possible Remote Extr/Adm control messages. MESSAGE 4 MEANING Rmt Extraction Disabled Remote Extraction is not selected Rmt Extraction Inhibitd Remote Extraction is inhibited and cannot be enabled Rmt Extraction Enabled Remote Extraction is enabled but not in control of the Setpt Remote Extract Active Remote Extraction is in control of the Setpt but not in control of the actuator output Remote Extr In Control Remote Extraction is in control of the Setpt and in control of the actuator output Remote Ext/Adm Disabled Remote Extr/Adm is not selected Rmt Extr/Adm Inhibited Remote Extr/Adm is inhibited and cannot be enabled Remote Extr/Adm Enabled Remote Extr/Adm is enabled but not in control of the Setpt Remote Extr/Adm Active Remote Extr/Adm is in control of the Setpt but not in control of the actuator output Rmt Extr/Adm In Control Remote Extr/Adm is in control of the Setpt and in control of the actuator output Rmt Admission Disabled Remote Admission is not selected Rmt Admission Inhibited Remote Admission is inhibited and cannot be enabled Rmt Admission Enabled Remote Admission is enabled but not in control of the Setpt Remote Admission Active Remote Admission is in control of the Setpt but not in control of the actuator output Remote Adm In Control Remote Admission is in control of the Setpt and in control of the actuator output Table 5-14. Remote Extr/Adm Messages The remote Extr/Adm control indications shown in Table 5-14 are available through the Modbus links: Remote Extr/Adm is Enabled, Remote Extr/Adm is Active, Remote Extr/Adm is In Control, Remote Extr/Adm is Inhibited, and Remote Extr/Adm Input Failed Alarm. In addition to these indications, the Remote Extr/Adm Input Setpoint is also available. Relay indications can be programmed to indicate Remote Extr/Adm Control Active and Remote Extr/Adm Control Enabled states. Alarms The ALARM key is always active in the RUN mode.
Figure 5-17 shows the screen that appears when this key is pressed. If there are no alarms detected, the screen will display the ‘Alarms Cleared’ message. When an alarm is detected, the Alarm relay is energized and the front panel Alarm key illuminates. In addition, the screen will automatically “jump” to the ALARM screen (as defaulted in the Service mode) and display the alarm condition. Table 5-15 lists all the potential alarm conditions and their cause. If more than one alarm condition is present, pressing the Down Arrow key will scroll through all active alarms. To view the most recent alarm, select the ALARM key. To clear any alarms that are no longer present, press the front panel RESET key, close the Reset contact input, or select Reset from either Modbus communications link.
Contact Us
- Temporal Ming sheng automation equipment co., LTD
Product Categories
New Products
Popular Searches
- spare parts
- remote control
- Pcb Circuit
- home automation
- smart home system
- pcb assembly
- circuit board
- energy saving
- Lighting System
- control panel
- Control Box
- Pcb Design
- pcb module
- lab equipment
- remote control switch
- Wire Harness
- Silicone Bracelet
- industrial dehumidifier
- Rubber Keyboard
- silicone keypad
- computer mainboard
- mainboard
- access control equipment
- Solenoid Valve
- Power Distribution Equipment
- Radio Remote Control
- Crane Remote Control
- Industrial Wireless Remote Control
- Industrial Radio Remote Control
- Multilayer Circuit Board
Recommended Products
- ABB 3BHE024747R0101 GDC801A101
- ABB HIEE300900R0001 PPC322 BE
- Bently Nevada 330104-00-16-10-11-00
- ABB SDCS-CON-4 3ADT313900R1501
- Honeywell 51451326-504
- Bently Nevada 330500-00-00
- Bently Nevada 330101-23-34-10-02-05
- Bently Nevada 330902-00-25-10-02-05
- ABB CI867AK01
- ABB CI858K01
- ABB SPHSS03
- ABB CI856K01
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile