BENTLY 3500/53 133388-01
- T/T
- 1 days
You May Like
Product Details
Brand Name | BENTLY 3500/53 133388-01 | Place of Origin | China | |
Model Number | BENTLY 3500/53 133388-01 |
Product Description
Brand: BENTLY
Type:3500/53 133388-01
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
The maximum total limit on CEX-Bus is the electrical one, there might be further limitations due to performance for a particular unit. (3) Only one port (CH1) is used in the interfaces CI868, CI871 and CI873. If redundant controllers (PM8XX) are used along with redundant communication interfaces, it ensures full redundancy and supports the online upgrade of firmware.It is recommended to make a practice of always starting an IPConfig session with a “Restore factory settings” command before assigning the intended IP addresses. This will erase previously stored alternative MAC and IP addresses if any
Single CPU Configurations The IP address of the CN1 port on the controller is set using the IPConfig tool (this tool is installed together with the 800xA system). See IPConfig online help. If network redundancy is used, make sure that the CN1 port is connected to the primary network, and the CN2 port is connected to the secondary network. In this case, you also have to set the IP address for the CN2 port. See IPConfig online help. Redundant CPU Configurations In configurations with redundant CPU, the IP address must be set as follows:Set the IP address of the CN1 port on the backup CPU. Use default settings (0.0.2.0 is added to the address of the primary CPU), unless your network administrator requires otherwise. See IPConfig online help.4. Start your 800xA Workplace. 5. Create a representation of the controller in the Project Explorer hardware tree. Make sure the PM861/PM864/PM865/PM891 processor unit is defined as redundant. See Control Builder online help. 6. In Project Explorer, set the IP address of the controller to the IP address of the primary CPU. See Control Builder online help. 7. Switch on the secondary CPU. Check that you have communication with the controller.There is no need to set IP address(es) for the backup CPU in Control Builder. The IP address of the backup CPU, CN1 and CN2 ports will only be used for internal communication between the primary and backup CPUs.
When the backup CPU takes over, it also takes over the primary IP address that is defined in Control Builder. Other units on the control network will never notice the switchover.I/O Systems There are several methods of connecting I/O systems to the AC 800M Controller: ? S100 I/O via CI856. ? S800 I/O units via the ModuleBus. Support for hot configuration during run, redundancy on all levels, HART routing, and Sequence-of-Events (SOE). ? S800 I/O units via CI854/CI854A and CI840/CI840A, PROFIBUS DP. Support for HART routing, redundancy on all levels, and hot configuration during run.
Contact Us
- Temporal Ming sheng automation equipment co., LTD
Product Categories
New Products
Popular Searches
- control system
- remote controller
- pressure sensor
- pressure transducer
- pressure transmitter
- temperature indicator
- temperature regulator
- temperature controller
- temperature control
- thermocouple
- communication module
- pump control
- power amplifier module
- pa module
- yokogawa pressure transmitter
- differential pressure measurement
- plc module
- analog input module
- yokogawa module
- yokogawa transmitter
- yokogawa
- dp transmitter
- master module
- dcs digital output module
- power inverter
- solar energy
- remote control
- solar power
- solar system
- solar charger
Recommended Products
- UFC762AE101 3BHE006412R0101 Control System DCS Spare Parts Spot Goods
- DSMB-01C Spare Parts of Inverter Power Boards for Frequency Converters Fast Delivery Power
- RS-FS-9001 362A1052P404 Spiral Joint Fluid Control System
- Vibro-meter VM600 RPS6U 200-582-200-011 Vibration Sensor Detection System
- TRICONEX 4351B Control Module
- FOXBORO FCP270 P0917YZ Controller Module
- H201Ti Monitor Industrial Control DCS System
- UNITROL 1020 UNS0119A-Z V1 3BHE030579R0003 Excitation Static Controller
- Vibro-meter 200-560-000-018 200-560-101-015 VM600 IOC4T Module/Controller
- EMERSON VE3008 CE3008 KJ2005X1-MQ1 12P6381X042 Industrial Automation System Module
- ALSTOM N897164624A Module/controller Redundancy Positioning System
- ALSTOM N895314513L Data Acquisition Module
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile