5SHY3545L0016 3BHB019719R0101 GVC736BE101 5SXE06-0160
- 74 Piece / Pieces per Month
- T/T
- 1 days
You May Like
Product Details
Brand Name | GVC736BE101 5SXE06-0160 | Place of Origin | China | |
Model Number | 5SHY3545L0016 3BHB019719R0101 |
Product Description
Brand: ABB
Type:5SHY3545L0016 3BHB019719R0101
Origin: the Swiss
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Mark III Improvements ? Completely overhauled with improved sensor durability, new electronic boards and power supply to make it RoHS compliant while increasing device reliability and capabilities ? Suitable for transformers using mineral insulating oil but now also ester based oils (natural or synthetic) ? Compatibility with GE’s acclaimed Perception? software to download, trend and analyze transformer data
Transformer Models The Hydran M2 offers transformer mathematical models based on IEEE standards and correlated with field experience. They use inputs from the available sensors and transform the received data into useful real time information to further understand the overall health of the transformer. Possible models output examples: ? Estimated winding hot spot temperature ? Moisture level in paper ? Moisture bubbling temperature ? Insulation ageing ? Overloading capacity ? Cooling efficiency ? OLTC temperature differential
Gas Sensor Fuel cell type sensor behind a gas permeable membrane in contact with transformer insulating oil Measurement range 0-2000 ppm (volume/volume, H? equivalent) Measurement accuracy ± 10 % of reading ± 25 ppm (H? equivalent) Measurement repeatability highest of ± 5 % of reading or ± 5 ppm Relative sensitivity H?: 100 % of concentration CO: 15 ± 4 % of concentration C?H?: 8 ± 2 % of concentration C?H?: 1.5 ± 0.5 % of concentration Response time 10 minutes (90% of step change) Moisture Sensor Thin film capacitive type sensor immersed in insulting oil Measured range 0-100% RH Measurement accuracy ± 2% RH Measurement repeatability ± 2% RH FEATURES Display Backlit LCD, 128 x 64 pixels Keypad to setup unit and acknowledge alarms Digital Communications RS-232 port (DB-9 connector), for local connection to computer for configuring the system RS-485 (terminal block), isolated to 2000Vac RMS, for remote communication or connection to local Hydran network Gas and moisture level and trend data output using Hydran, Modbus?, DNP 3.0 or IEC 61850 protocols over RS-485
Contact Us
- Temporal Ming sheng automation equipment co., LTD
Product Categories
New Products
Popular Searches
- Control System
- remote controller
- pressure sensor
- pressure transducer
- pressure transmitter
- temperature indicator
- temperature regulator
- temperature controller
- temperature control
- thermocouple
- Communication Module
- pump control
- power amplifier module
- Pa Module
- yokogawa pressure transmitter
- differential pressure measurement
- Plc Module
- Analog Input Module
- yokogawa module
- yokogawa transmitter
- yokogawa
- dp transmitter
- Master Module
- Dcs Digital Output Module
- Control Cable
- Control Transformer
- Solenoid Valve
- automation equipment
- Control Cabinet
- Pressure Control Valve
Recommended Products
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile