Home > Products > Tester Equipment > HT9600 PM2.5 Detector Air Quality Monitor Particle Counter Dust Sampling Meter Gas Analyzer
HT9600 PM2.5 Detector Air Quality Monitor Particle Counter Dust Sampling Meter Gas Analyzer
- 1000 per Month
- T/T Credit Card
You May Like
-
MR9270S+ Current Voltage PT100 Thermocouple 4-20mA Signal Generator Signal Calibrator
-
Chinese English Menu FS9000 Battery Type Nuclear Radiation Detector Radiation Dosimeter Detector
-
2 In 1 Digital Oscilloscope + Multimeter 40MHz 250MSa/s Direct Charging Type 2C42
-
Versatile LB02 Resistance Current Voltmeter Signal Generator Source Process Calibrator
-
LB01 4-20mA/0-10V/mV Resistance Current Voltmeter Signal Generator Source Calibrator
-
EBC-B20H 12V-72V 20A Lead Acid Lithium Battery Capacity Tester Sup External Charger Automatic Charge & Discharge
Product Description
HT9600 PM2.5 Detector Air Quality Monitor Particle Counter Dust Sampling Meter Gas Analyzer
Overview:
Handheld dust quick detector is the special detecting instrument used to measure the value of PM2.5 (repairable particles) and PM10 (inhalable particle) in the air. It is a high-tech product developed independently and integrating gas dynamics, digital signal processing and optical-mechanical-electrical integration on the basis of absorbing oversea advanced high sensitivity micro laser sensor technology. The device is characterized by high test precision, stable performance, strong multiple functions and easy and convenient operation and can be used widely for determination of indoor and outdoor public environment and atmospheric environment, PM2.5 air quality detection and PM2.5 dust particle amount.
II.Specification:
- PM2.5 air quality detection: PM2.5 Pm10
- Range: (0-1000ug/m3 )
- Concentration unit: ug/cubic meter (ug/m3)
- Detection sensitivity: 1ug
- Measurement error: < ±20%
- Three-channel dust particle counter: 0.3um 2.5um 10um
- Flowrate: 1L/min
- Concentration unit: piece/L
- Sampling method: pumping
- Sampling principle: light scattering
- Light source: laser diode
- Detection method: manual
- Automatic power-off function: it will power off automatically if there is no operation within 2 minutes at power-on state.
Environmental condition:
- Application environment: temperature scope: 5~45degree C
- Humidity range:<90%RH
- Storage environment: temperature scope: -20~60degree C
- Humidity range:<90%RH
- Sampling time: 50s
- Resolution ratio of sensor: 1ug/m3
- Storage record: 1000 groups of data
- Temperature measurement range: -40~ +125 degree C Precision ±0.5degree C
- Humidity measurement range: 0-100%RH Precision ±2%RH
- Screen size: 2.8"
- Display screen: 2.8″320*240 LCD color back light
Power supply:
- Adaptor: 100-240VAC 50/60H output; DC9V=500mA (the connection is used for charging and should be used at power-off state).
- Connection of USB port line
- 7.4V Rechargeable lithium battery/1100mAh (the battery cannot be dismantled at will. Please contact the manufacturer is it needs to dismantle the lithium battery).
- Work time of the battery: the time for continuous test is longer than 3 hours.
- Display of remaining energy: three-grid battery electricity display (it needs to charge if one grid of electricity is left. The charging should be made before the battery electricity displays red. This will result in reducing service life and capacity of the battery). The electricity is tested once at the time of power on.
- External size: 245*40*85mm
- Weight: 325g (battery included)
III. Use method
Power on
- Take out the product from the package. After the power key is pressed, product LOGO is displayed and it enters the main page and displays the interface of dust particle number/L or PM2.5 air quality ug/m3 (interface may be changed at functional parameters).
- Power off: At power-on state of the instrument, press power key ( )to power off. The instrument will power off automatically if there is no operation within 2 minutes.
Note:
- When power supply of battery and adapter exists at the same time, the circuit adopts adapter as power supply. 1. When the adapter is disconnected, the circuit adopts battery as power supply.
- When power adapter is used to provide supply, it is not necessary to pull off the plug of the power adapter. If there is no operation within two minutes, the instrument will power off undoubtedly and automatically. After automatic power off, the adapter charges the lithium battery. The time of charging is two hours.
- The instrument will appear with sleep state if it is not used for a long time and cannot power on. At the moment, adapter may be disconnected to wake up the circuit of power supply. If the electricity display on the top right corner is not three grids of full electricity after powering on, it is necessary to charge the battery of the instrument.
Description of key function
- RUN key: Press the key once and the instrument’s screen displays the sampling time and begins countdown of 50s. The collected data is displayed once every 10s. For the collected data, the data of last collected is correct reference data.
- When Down key is pressed once, the instrument enters historical record →functional parameter setting in proper order. Data may be checked at the bottom of history page. Press ENTER to confirm the state of certain page for specified check of current page in historical record. At the moment, SHIFT key may be used to select hundred place ←tens place← unit place of current page. Press UP () key or DOWN () key to select 001-999 page of current page.
At the page of functional parameters, press ENTER to confirm that functional parameters enter change state. At the moment, use SHIFT to select the item to be changed. Press UP () key or DOWN () key to select the function. Press ENTER to confirm completion after selection. Change of parameter function is completed at the moment. Press BACK key to return to previous interface until to the main interface.
IV. Characteristic of product
- Direct reading of dust concentration and digital display;
- Innovative electronic cutting technology;
- High detecting precision with the principle of light scattering;
- Quick response to detection;
- Convenient operation and no need for maintenance
- Power supply by efficient, large capacity lithium battery;
- Intelligent recognition automatic power off saves power to the greatest extent.
- Display of representative color for pollution level;
V. Display description
1. Time/date
2. Area corresponding to representative color for pollution level;
3. Diameter size of measured particles;
4. Temperature/humidity
5. Air quality measurement
6. Measurement for amount of dust and particles in the air;
7. Power display
VI. Product description
1. LED display screen
2. Power key
3. RUN key
4. ENTER key
5. SHIFT key
6. BACK key
7. UP key
8. DOWN key
VII. Standard of indexes
- Schematic diagram of air quality level
- Excellent
- Good
- Slight pollution
- Moderate pollution
- Heavy pollution
- Serious pollution
VIII. Considerations
- The device cannot be started if the inlet pipe is covered or blocked.
- The product should be placed at a horizontal, dry environment without direct sunlight for storage.
- The product should not be placed in an environment with PM2.5 concentration exceeding 999ug/m3. Exposure to air with high concentration of pollution will result in damage of the sensor so that the equipment cannot work normally.
- The product should be placed at an area with slow air circulation when it is used for measurement to prevent interfering with the detection result caused by direct blowing of strong air blowing to the inlet pipe.
- The product is not provided with waterproof function. Don’t splash water or other liquid onto the device. The service hotline should be dialed at once in case of such condition.
- The device should not be used in environment vulnerable to invasion of rain, snow and humid climate. Otherwise, failure may be brought to it.
- Don't dismantle and repair the product without authorization. This may result in failure of the device. Please dial the service hotline if there is any doubt. Our company will not undertake any responsibility for any loss with respect to unauthorized dismantling.
- The device should be placed at a stable and safety site to avoid dropping off of the device body.
Package Contents:
- 1 x HT9600 PM2.5 Pm10 Air Analyzer
- 1 x Manual
- 1 x Carry case
Package: Normally we use the standard exporting packaging. We also can according to clients' request .
Shipping :
1. By Couriers: DHL, UPS, FEDEX, TNT are the main courier we are co-operating at present.
2. By Air: Delivery from the Shanghai airport to customers’ destination city air port.
3. By Sea: Delivery from the Shanghai sea port .
Aiming to provide high quanlity products and great service for buyer,we are strict on product quanlity control and offer instant communication service.Welcome to contact us!
Our Advantages:
- Source only the best consumer goods and ensure the highest quality.
- Streamline the buying and payment process, and make it as easy as possible.
- Help the customers all over the world discover products and manufacturers in China.
- The Shortest order processed time and speed delivery
Q1. Can I have a sample order?
A: Yes, we welcome sample order to test and check quality.
Q2. What about the lead time?
A: Samples arrived often need 3-5 days.
Q3. Do you have any MOQ (minimum order quality)limit?
A: Low MOQ, 1pc for sample checking is available.
Q4. How do you ship the goods and how long does it take to arrive?
A: We often ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Airline and sea shipping is also optional.
Q5. How to proceed an order?
A: Initially, let us know your requirements or application. Besides, We quote according to your requirements or our suggestions. Thirdly, customers confirms the samples and places deposit for formal order. Finally, We arrange the production.
Q6. Is it acceptable to print my logo on the product?
A: Yes. Please inform us formally before our product and confirm the design firstly based on our sample.
Q7: Do you offer guarantee for the products?
A: Yes, we offer one-year warranty for our products.
Q8: How to deal with the flaw?
A: Our products are produced in strict quality control system and the percent of pass is often maintained over 99.8%
Please do not hesitate to contact me if you need any further information
Whatsapp/Tel/Wechat: 8619902906050
Web:
Address: Room 303 Building 2,Youpin Cultural and Creative Park,Zhangkeng,Minzhi Street,Longhua District,518131,Shenzhen,China(Mainland)
Contact Us
- Shenzhen Tianzhongtian Trading Co., Ltd.
Product Categories
Business&Industry | Comsumer&Electronics | Health&Care | Hobbies&Toys |
household products | Metal Detector | Tester Equipment | Ungrouped |
New Products
-
EBC-A20 Li-po Battery Capacity Tester 5A Charge 20A Discharge 85W Multifunction Battery Current Test
-
Watch MTG1900 Watch Tester Timing Multifunction Timegrapher Watch Expert no.1900
-
2.8\" Touch Screen 50KHz-900MHz Vector Network Analyzer Kit MF HF VHF UHF Antenna Analyzer with Shell
-
MS5910 Digital RCD Tester Multimeter Loop Resistance Tester for sale
-
NanoVNA Vector Network Analyzer 50KHz-900MHz HF VHF UHF Antenna Analyzer with 2.8\" LCD Display
-
868Mhz/915Mhz LORA Gateway Signal Analysis Strength LoRa Device Meter LoRaWAN Network Analyzer Tester
-
Versatile LB02 Resistance Current Voltmeter Signal Generator Source Process Calibrator
-
2 In 1 Portable handheld Hantek-2C42 2 channel 250msa 40mhz Digital Oscilloscope kit with Multimeter
-
EBC-A10H Li/Pb Battery Charging Capacity Test Power Performance Tester & Charger + USB to TTL Cable
-
EBD-A20H Battery Capacity Tester Electronic Load Power Tester Discharge Meter 0.1-20A 200W
-
UV UHF VHF Dual Band digital Spectrum Analyzer with Tracking Source 136-173MHz & 400-470MHz
-
BM500A 1000V 1999M Digital Insulation Resistance Tester Meter Megohmmeter Megger
-
3 In 1 Portable Handheld Hantek 2D72/2D42 2 Channel 250msa Digital Oscilloscope Kit with Multimeter
-
FY3200S 24MHz Digital LCD Dual-Channel DDS Counter Arbitrary Waveform Frequency Meter Signal Generator
-
12V 24V 48V Lead-acid Lithium 180W Constant Current Electronic Load 200V 20A Battery Tester Discharge Capacity Tester
-
FY3200S 12MHz Digital LCD Dual-Channel DDS Counter Arbitrary Waveform Frequency Meter Signal Generator
-
EBC-A40L 5V Battery Capacity Tester for Lithium Polymer Power Battery Discharge Charge
-
Portable Digital X-ray Beta Gamma Personal Dosimeter Geiger Counter Nuclear Radiation Detector
-
Portable Electronic Nuclear Radiation Detector Geiger Counter X-ray Beta Gamma English Chinese Menu FS311CHG Charging
-
FS9000 Portable Electronic X R Hard B ray Geiger Counter dosimeter personal Nuclear Radiation detector
-
VC3165 Radio Frequency Counter RF Meter 0.01Hz-2.4GHz Professional Tester Cymometer
-
NO.1000 Multifunction Timegrapher Watch Timing Machine Calibration tester Tools
-
3 In 1 Digital Oscilloscope + Waveform Generator + Multimeter 70MHz 250MSa/S Direct Charge 2D72
-
CR-C Multi Function Common Rail Injector Tester
Popular Searches
- Alcohol Tester
- alcohol breath tester
- alcohol tester breathalyzer
- alcohol detector
- breathalyser
- breath tester
- alcohol breathalyzer mouthpiece
- alcohol analyzer
- Breath Alcohol Tester
- Alcohol Content Tester
- Keychain Breath Alcohol Tester
- Alcohol Breathalyzer Tester
- Alcohol Breathalyzer
- gas detector
- breathalyzer
- Gas Analyzer
- Oxygen Analyzer
- Nitrogen Analyzer
- carbon dioxide analyzer
- Carbon Monoxide Analyzer
- Carbon Dioxide Meter
- Analyzer Co2 Meter
- Concentration Analyzer
- Concentration Controller
- Gas Analyzers
- gas instrument
- o2 analyzer
- o2 tester
- oxygen instrument
- Gas Detector Analyzer
Recommended Products
- 2025 KEONE Ultimate Wearable Gas Detector
- 2025 Wrist-Mounted Multi-Gas Detector
- Portable Biomethane Analyzer Gasboard-3200L
- Rexroth Pumps
- Siemens Gas Analyzers
- ABB laser gas analyzers
- ABB Gas Chromatograph Analyzers
- Endress+Hauser Gas Analyzers
- SICK Gas Analyzers
- Continuous Emissions Monitoring System for Marine Exhaust Gas Gasboard-9085
- AIXPRO Handheld XRF Ore Spectrometer – Portable Alloy & Mineral Analyzer for Geology, Mining, Soil Heavy Metal Detection, 50+ Elements, Instant Results with 0.1% Accuracy, IP54 Waterproof Design
- Handheld XRF Alloy Analyzer On-Site Alloy Grade Identifier Professional Alloy Material Detector
Find Similar Products By Category
- Instruments & Meters > Analysis Instrument > Gas Analyzer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile