JWJXC-H80/0.06 Stepless Reinforced Contact Slow Release Relay
You May Like
Product Description
|Product Introduction
JWJXC-H80/0.06 stepless enhanced contact slow release relay is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the switch, lock and unlock the path, and control the opening and closing of the signal machine. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system.
Product Usage
The JWJXC-H80/0.06 type stepless enhanced contact slow release relay is used as a switch-start relay in the switch control circuit of a high-power DC electric point machine (such as ZD7-C165/250). The relay strengthened contacts are specially designed for signal circuits with larger on-off power.
Features
1. The relay is a heavy elastic DC electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized.
2. The use of silver-silver oxidation requires contacts, which has the characteristics of strong anti-adhesion and low contact resistance.
3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and installs the stop piece at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the ferromagnetic parts of the magnetic circuit from magnetization, and ensure the reliable fall of the relay.
4. The magnetic circuit system is basically the same as the JWXC-H340 relay.
5. The relay contact system consists of two parts: ordinary contacts and reinforced contacts. There are two groups of moving on and off conversion ordinary contacts; there are two groups of moving on and off conversion reinforced contacts with magnetic arc blowers, and two groups without magnetic arc blowers. The dynamic break conversion strengthens the contact. The structure of ordinary contacts is the same as that of non-polar relays, and the strengthened contacts are specially designed high-power contacts and isolated isolation devices.
6. The rated voltage of the front ring of the relay is DC 24V; the rated current of the rear ring is 11A.
Applicable environment
a) Ambient temperature: -40℃~+60℃;
b) Relative humidity: not more than 90% (temperature +25℃);
c) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level);
d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;
e) Working position: horizontal;
f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.
Applicable characteristics
Mechanical properties
Number of contact groups: 2QH, 2QJ, 2H;
Identification pin number: 12, 22;
Contact gap: ordinary contact is not less than 1.3mm; reinforced contact is not less than 2.5mm;
Pallet gap: ordinary contact point is not less than 0.35mm; strengthened contact point 0.1mm~0.3mm;
Ordinary contact pressure: the dynamic contact point is not less than 150mN; the dynamic disconnection point is not less than 150mN;
Strengthen the contact pressure: the dynamic contact point is not less than 400mN; the dynamic disconnection point is not less than 300mN;
Contact uniformity error: between ordinary contacts and ordinary contacts, and between ordinary contacts and reinforced contacts, no more than 0.2mm, and between reinforced contacts and reinforced contacts no more than 0.1mm.
Electrical characteristics (at +20℃)
Coil resistance:
Use the coil alone, use 1, 23, 4;
Rated value: 24V/11A;
Magnetizing value: 40V/8A;
Working value: 11.5V/4A;
Release value: 2.5V/<1.3A;
Reverse working value: 12.6V/4.4A;
Slow release time is not greater than: the current of the rear coil decreases from 5A to 1.5A at 0.2S when the power is off;
Contact resistance: common contact is not more than 0.05Ω; reinforced contact is not more than 0.1Ω.
Insulation withstand voltage
Under the standard atmospheric conditions of the test, the insulation resistance of the relay should not be less than 100MQ.
Under the condition that the air pressure is not less than 86kPa (equivalent to the altitude below 1000m), the insulation withstand voltage of the relay should be able to withstand AC sine wave 50Hz,
1000V effective value voltage, there should be no breakdown flashover after 1min, and the voltage during repeated test should be 75% of the original test voltage.
Dimensions
Relay: 165mm×49 mm×163mm (length×width×height)
Socket: 157mm×48mm×22mm (length×width×height)
Structural characteristics
The electromagnetic system of the stepless enhanced contact slow release relay is the same as that of the stepless slow release relay (JWXC-H340). The magnetic circuit system of the JWJXC-H125/80 stepless enhanced contact slow release relay adds a copper short-circuit ring to make the slow release longer.
The contact system consists of two parts: ordinary contacts and enhanced contacts. The structure of ordinary contacts is the same as that of non-polar relays, and the reinforced contacts are sp
Contact Us
- German Railway Track Equipment (Zhejiang) Co., Ltd
Product Categories
relay |
New Products
-
JJJC3 AC enhanced contact relay
-
JJC type AC relay
-
JJJC1 AC enhanced contact relay
-
JJJC5 AC enhanced contact relay
-
JSBXC1-870 programmable time relay
-
JSBXC-780 programmable time relay
-
JSBXC1-850 programmable time relay
-
JMS2-110 Pulse Relay
-
JZSJC2 AC Filament Conversion Relay
-
JMS2-110 Pulse Relay
-
JZSJC2 AC Filament Conversion Relay
-
JMS2-110 Pulse Relay
Popular Searches
- auto parts
- automotive relay
- general purpose relay
- car relay
- ssr
- ac contactor
- contactor
- solid state relay
- pcb relay
- Power Relay
- Time Relay
- mcb
- circuit breaker
- wall switch
- dc contactor
- thermal overload relay
- hongfa
- meter component
- Power Meter
- Wall Socket
- Latching Relay
- Auto Relay
- Magnetic Latching Relay
- High Power Relay
- Industrial Relay
- auto parts
- automotive relay
- general purpose relay
- car relay
- ssr
Recommended Products
- Temperature monitoring relay PT100/1000, 3RS2041-1GW50 NTC, spiral
- 41A325938G2 GE CARD KOMATSU 830E 930E MT4400AC MT3600 MT3700 NHL NTE240 NTE260
- GE1483 CARD KOMATSU 830E 930E 730E MT4400AC MT3600 MT3700 NHL NTE240 NTE260 NTE160
- Phoenix Contact Safety relay PSR-SCP-24DC/ESP4/2X1/1X2 2981020
- One New SCHNEIDER LADT2 0.1-30s Time Delay Block
- Schneider RM22TG20 3 Phase Control Relay RM22-TG
- Omron G3PE-225B 12-24VDc Solid state relay
- New original YOKOGAWA Yokogawa PLC F3LX02-0N
- 1734-TOPS Module Rockwell Allen-Bradley new stock 1734TOPS
- 1734-EPAC Power module Rockwell Allen-Bradley Brand new spot 1734EPAC
- 855P-B30ME22 Buzzer Rockwell Allen-Bradley New stock 855PB30ME22
- 2094-EN02D-M01-S0 Control module Rockwell AB new spot 2094EN02DM01S0
Find Similar Products By Category
- Electrical & Electronics > Relay & Contactor > Relay
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile