JYXC-660 Pole Relay
You May Like
Product Description
Product Introduction
The JYXC-660 poled relay is an important element in the interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the route, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays.
Product Usage
The JYXC-660 poled relay is used as a general poled relay in the signal circuit.
Applicable environment
The applicable environment of the relay is:
a) Ambient temperature: -40℃~+60℃;
b) Relative humidity: not more than 90% (temperature +25℃);
c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);
d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;
e) Working position: horizontal;
f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.
Product function
The JYXC-660 poled relay is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits.
Mechanical properties
Number of contact groups: 6DF;
Identification pin number: 15, 52;
Contact gap: not less than 1.3mm;
Pallet gap: not less than 0.35mm;
Contact pressure: the positioning contact is not less than 250mN; the reverse contact is not less than 250mN;
Positioning or reverse position retention force is not less than 2N;
Contact uniformity error: not more than 0.20mm.
Electrical characteristics
Coil resistance: 330 (1±10%) Ω×2
The coils are connected in series, connect 2, 3, use 1, 4;
Rated value: DC24V;
Magnetizing value: DC60V;
The extreme value of rotation: 10V~15V;
Contact resistance: not more than 0.05Ω.
Features
1. The relay is designed according to the needs of the bistable circuit in the signal circuit. Permanent magnets are added to the magnetic circuit system of the relay, so that the relay has two stable states of positioning and reverse due to the different polarity of the current in the coil. These two stable states can continue to be maintained after the current in the coil disappears.
2. The use of silver-silver oxidation requires contacts, which has the characteristics of strong anti-adhesion and low contact resistance.
3. The relay contact system consists of common contacts, with six groups of common contacts for positioning and reverse conversion.
4. The rated voltage of the relay is DC 24V.
test method
Standard test conditions:
Temperature: +15℃~+45℃;
Relative humidity: 45%~75%
Air pressure: 86kPa~106kPa
Requirements for testing measuring tools, meters, and power supply:
The accuracy of the measuring tool for measuring appearance and installation dimensions should not be less than 0.05mm; the accuracy of the feeler gauge should not be less than level 2; the measurement error of the force measurement should not be greater than 2%. The accuracy of the DC voltmeter and ammeter used for testing should not be less than 0.5, and the accuracy of the AC (50Hz) voltmeter and ammeter should not be less than 1. The power supply voltage should remain stable, and its fluctuation range should not exceed 5%. The DC power supply should be a DC generator, battery or AC full-wave rectifier power supply (except for special regulations, the ripple factor should not be greater than 5%). The waveform of the AC power supply should be a sine wave with a frequency of 50 Hz.
Dimensions
Relay: 165mm×49mm×163mm (length×width×height)
Socket: 157mm×48mm×22mm (length×width×height)
Faults and troubleshooting methods
Relay contact has no output
The analysis and elimination methods of the relay contact without output are as follows:
(1) Make sure that the relay and socket should be reliably plugged in;
(2) Check that the relay should not be mechanically blocked. If foreign matter in the relay blocks the armature, the armature cannot work reliably (forward rotation) or release (reverse rotation), and the contacts cannot be reliably contacted;
(3) Check that there should be no foreign matter between the contacts, there is foreign matter between the contacts, and the contacts cannot be reliably contacted;
(4) Check that the contact resistance of the relay contact should not be too large. The relay does not work or the relay with a pole cannot be reversed in the forward direction
The relay does not work or the relay with a pole cannot be reversed in the forward direction
(1) Make sure that the relay and socket should be reliably plugged in;
(2) Check that the input voltage or current of the relay coil should be the rated value or the system circuit adjustment value.
Method: Use a multimeter to check the voltage relay coil input terminal voltage on the socket should meet the output voltage of the power supply relay; use a multimeter to check the current relay coil input terminal voltage drop on the broadcast base should meet the voltage drop requirements for the reliable operation of the relay in the system circuit; otherwise Is a system failure;
(3) If the above two items are normal, it can be determined that the relay is faulty and the relay should be replaced;
(4) The relay coil is short-circuited or disconnected, the relay cannot work reliably or has a pole relay;
(5) The diode of the rectifier relay is impacted or short-circuited, and the rectifier relay cannot work reliably;
(6) Check that the relay should not be mechanically blocked. If a foreign object in the relay blocks the armature, the relay cannot work reliably or reverse poles in the forward direction.
The relay is not released or the relay with a pole cannot be reversed in the forward direction
The relay non-release analysis and troubleshooting methods are as follows:
(1) Make sure that the relay and socket should be reliably plugged in;
(2) Check that the input voltage or current of the relay coil should meet the requirements of the system circuit for reliable release of the relay.
Method: Use a multimeter to check that the voltage relay coil input terminal voltage on the socket should be less than the release voltage of the relay; use a multimeter to check that the voltage drop of the current relay coil input terminal on the socket should meet the requirements for reliable release of the relay in the system circuit; otherwise, it is a system failure;
(3) If the above two items are normal, it can be determined that the relay is faulty and the relay should be replaced;
(4) Check that the relay should not be mechanically blocked. If a foreign object in the relay blocks the armature, the relay cannot be reliably released.
Insulation withstand voltage
Under the standard atmospheric conditions of the test, the insulation resistance of the relay should not be less than 100MQ.
Under the condition that the air pressure is not less than 86kPa (equivalent to the altitude below 1000m), the insulation withstand voltage of the relay should be able to withstand AC sine wave 50Hz,
2000V rms voltage, there should be no breakdown flashover after 1 min, and the voltage during repeated test should be 75% of the original test voltage.
Installation method
The relay socket is installed on the combination frame (cabinet) with bolts, and the relay is horizontally inserted into the socket and clamped with a hanging spring.
Relay identification pin numbers 15, 52.
Product electrical life
The relay contacts are connected to DC24V1A resistive load; its electrical life is 4×105 times.
Contact Us
- German Railway Track Equipment (Zhejiang) Co., Ltd
Product Categories
| relay |
New Products
-
JJJC3 AC Enhanced Contact Relay
-
JJJC3 AC Enhanced Contact Relay
-
JJC Type AC Relay
-
JJJC1 AC Enhanced Contact Relay
-
JJJC5 AC Enhanced Contact Relay
-
JSBXC1-870 Programmable Time Relay
-
JSBXC-780 Programmable Time Relay
-
JSBXC1-850 Programmable Time Relay
-
JMS2-110 Pulse Relay
-
JZSJC2 AC Filament Conversion Relay
-
JMS2-110 Pulse Relay
-
JZSJC2 AC Filament Conversion Relay
Popular Searches
- automotive relay
- general purpose relay
- car relay
- ssr
- ac contactor
- contactor
- solid state relay
- pcb relay
- power relay
- time relay
- mcb
- circuit breaker
- wall switch
- dc contactor
- thermal overload relay
- hongfa
- meter component
- power meter
- wall socket
- latching relay
- auto relay
- magnetic latching relay
- high power relay
- industrial relay
Recommended Products
- Bosch Rexroth HMV01.1R-W0018-A-07-FNN1: Precision Hydraulic Valve Control Module
- MOOG D137-001-007: Solving Motion Control Drift in Demanding Industrial Setups
- B&R 7AI261.7: Precision Analog Input That Won’t Ghost Your Process Data
- Why Your Turbine Vibration Monitoring Can't Afford Cheap Probes: Bently Nevada 3300 XL 8mm (330101-00-16-10-02-00)
- Bently Nevada 330101-23-39-10-12-CN Proximity Probes: Precision Vibration Monitoring for Critical Machinery
- Fanuc A06B-6141-H022#H580: Your CNC Spindle’s Quiet Powerhouse for Heavy-Duty Cuts
- Bently Nevada 330103-00-07-05-02-05 3300 XL 8 mm Proximity Probe: Precision Shaft Monitoring for Critical Machinery
- HIMA F3 DIO 20/8 02: Precision Safety Control for Critical Industrial Operations
- Why the ICS Triplex T8300 Expander Won’t Let Your Critical Process Stumble
- HIMA X-FAN 18 03: Your Cabinet's Silent Guardian for Critical Control Systems
- HIMA F3105 Smart Safety Controller: Your Last Line of Defense in Critical Processes
- Fanuc A06B-6290-H208: Precision Spindle Control That Won’t Quit on Your CNC Line
Find Similar Products By Category
- Electrical & Electronics > Relay & Contactor > Relay
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile
JWJXC-H80/0.06 Stepless Reinforced Contact Slow Release Relay
JJJC3 AC Enhanced Contact Relay
JJC Type AC Relay
JZSJC2 AC Filament Conversion Relay
JMS2-110 Pulse Relay
JZXC-H62 Rectifier Slow Release Relay