Home > Products > Pressure transmitter > Single-flange-level transmitter 3051Intelligent differential pressure transmitter
Single-flange-level transmitter 3051Intelligent differential pressure transmitter
- tianjin
- T/T L/C D/P D/A
- 15 days
You May Like
Product Details
Brand Name | kyue | Place of Origin | China | |
Model Number | ky300DP |
Product Description
The two pressures of the flange level transmitter of the measured medium pass into the high and low pressure chambers acting on the isolation diaphragm of the element (i. e., the sensitive element) and transmitted to both sides of the measuring diaphragm through the isolation diaphragm and the filler fluid inside the element.The flange level transmitter is made of a measuring diaphragm with two insulating insulation
The electrodes each form a capacitor.When the pressure on both sides is inconsistent, the measurement diaphragm produces a displacement, its displacement amount is proportional to the pressure difference, so the electric capacities on both sides are different, through the oscillation and demodulation link, converted into a signal proportional to the pressure.
Characteristics
● high accuracy and good stability.
● second-line working mode, 4~20mA or 0~10mA signal output.
● sensitive parts and circuit boards are fully solid and vibration resistant.
● has strong anti-interference ability and good temperature stability;
● explosion-proof shell structure, available all weather.
● has the best corrosion performance, ensure the best cost corrosion performance.
● structure is light, simple and reasonable, no support, no horizontal installation, can be installed directly at any position.
Working principle
Principle
During operation, the isolation diaphragm on the high and low pressure sides and the filling fluid will transfer the process pressure to the central filling fluid, and the central filling fluid will transfer the pressure to the sensing diaphragm at the center of the δ— chamber sensor.The sensing diaphragm is a tensional elastic element whose displacement varies with the differential pressure (for the GP surface pressure transmitter, the atmospheric pressure is as applied on the low pressure side of the sensing diaphragm).AP booster transmitter, the low pressure side always maintains a reference pressure.The maximum displacement of the sensing membrane is 0.004 inches (0.10 mm).The displacement amount is proportional to the pressure.The amplifier circuit of the two capacitance fixing plates of the measurement diaphragm is linearly converted into a second-line current, voltage, or digital HART(high-speed addressable remote transmitter data highway) output signal of 4~20mA DC
Main technical indicators
Technical indicators
Use the object liquid, gas, or steam
Range pressure: 0~10Kpa ~7Mpa;
Negative pressure: -100KPa ~7MPa
Output 4~20mADC
Power supply is 12~45VDC
Load feature 4~20mADC second-line production load
R ≤ 50 (V13) (see Figure-2)
Temperature Range Environmental temperature: -40~+ 85℃;
Storage temperature: -40~+ 85℃
Standard medium temperature: -20~+ 104℃
The enclosure is better than IP65
Explosion-proof type type ia Ⅱ CT5 shall be equipped with external safety grille
Performance indicators
Comprehensive precision: The standard provides 0.25%, the maximum accuracy of ± 0.1%BFSL stability is better than ± 0.1%BFSL/ years
Temperature effect: in the range of-20~+ 70℃, the change amount is less than ± 0.18% / 10℃
Vibration effect: if the vibration frequency of 20.00% Hz in any direction is less than 20-200% BFSL
Impact : After 11 ms of 100G in any direction, the change is less than ± 0.02% BFSL
Load impact: No load effect as long as the terminal voltage of the input transmitter exceeds 12V,There was no position effect
Structural indicators
Structural materials
Membrane sheet: silicon
Case: low copper cast aluminum
Contact medium material: SUS304
"Type O" ring sealing structure: nitrile rubber, polytetrafluoroethylene, or fluorine rubber
Process Connection: Flange connection to the Flanged connection
Electrical connection: It can be drawn from either outlet as required and it is recommended to use φ 10 industrial cable as the lead for sealing.
General cable connector may be selected: PG16 or M20 × 1.5 without lead end sealed with end cover.
Structure and installation method
Gong said Radial DN Nominal through diameter DN
| The flange outer diameter D Flange outside diameter D
| The central circle diameter of the bolt hole is K Bolt circle K
| L of bolt hole diameter Bolt hole size L
| The number of bolts is N Nos. of bolts N
| Bolt size is TH Bolt Size TH
| Seal surface diameter D1 Sealing face diameter D1
| Seal surface Height F Sealing face height F
| Farland Thickness C Flange thi ckness C
|
50 | 165 | 125 | Φ 18
| 4 | M16 | 99 | 3 | 20 |
80 | 200 | 160 | Φ 18
| 8 | M16 | 132 | 3 | 24 |
100 | 235 | 190 | Φ 22 | 8 | M20 | 156 | 3 | 24 |
Figure-4 is the flange structural schematic and dimension table unit (mm)
1. It is installed directly on the measurement point (at any angle).
2. tries to install on pressure measurement with small temperature gradient and temperature fluctuations, while avoiding strong vibration and shock.
3. outdoor installation, place in the protective box as much as possible from direct sunlight and rain to maintain transmitter performance stability and extended service life.
4. When measuring steam or other high temperature medium, be careful not to overlimit the operating temperature of the transmitter.Install the radiator or other cooling device connection when necessary.
5. installation, the pressure stop valve shall be installed between the transmitter and the medium to repair and prevent the blocked pressure outlet and affect the measurement accuracy.In the pressure fluctuation paradigm Damper or pressure buffer shall also be added for the enclosure.
Note: The components or structures that may affect the explosion-proof performance shall not be replaced or changed at will.
System connection and commissioning
The transmitter is recommended to choose the power supply voltage Us of 24V. in the systemDC .
The resistance value of the sampling resistance (load resistance) RL in the secondary instrument is 250 Ω.If Us and RL choose other values, then the RL value cannot exceed the value calculated by the formula.
The power supply is connected to the transmitter through the signal cable. The connection holes on the top sides of the transmitter are sealed by cable or signal cable. The signal cable is locked by the fastening nut, and the unused connection port must be sealed.
Wiring diagram of the A: measuring system
The shielding signal cable must be used in the system circuit and reliably grounded.
The transmitter has been factory according to the user needs, the range, accuracy have been adjusted to the best condition, generally need not check.However, the following conditions shall be rechecked:
A.Drop, strong shock and collisions in transport;
B.Storage period is more than one year;
C.After long operation, an error greater than the range of accuracy;
D.Routine inspection of the use unit.
Contact Us
- Kyue Measurement & Control
- Contact namefeng Chat Now
- Phone86-022-81369072
Product Categories
Pressure transmitter | Pressure sensor | Pressure switch | Temperature products |
Liquid level product | DRUCK | pressur gauge | pressure gauge |
flowmeter | Chemical seal |
New Products
-
2088Industrial pressure transmitter 4-20mA/HART/RS485 24VDC
-
3051Intelligent pressure transmitter 4-20mA/HART/RS485 M20*1.5 1/2NPT
-
3051Intelligent differential pressure transmitter 24VDC 4-20mA/HART
-
Chemical seal
-
Diaphragm pressure switch
-
Thermal resistance 316&customized PT100
-
Intelligent temperature transmitter 2/3/4 wire Hart/RS485
-
Standard economical pressure transmitter 4-20mA Hart/RS485
-
putting-into-type liquid level meter 24VDC 4-20mA HART5.0
-
putting-into-type liquid level meter 24VDC 4-20mA HART5.0
-
Float liquid level gauge 4.0Mpa
-
Vortex Flowmeter
-
Coriolis mass flowmeter RS485/HART
-
Druck DPI 104 digital standard pressure gauge
-
PV210 Druck Low Pressure and Vacuum Hand Pump
-
Standard economical pressure transmitter 12-36VDC 4-20mA M20*1.5
-
Special hydraulic pressure transmitter 12-36VDC 4-20mA G1/4
-
Cable type pressure transmitter 12-36VDC 4-20mA&customized 1/2NPT
-
Flat film pressure transmitter 12-36VDC 4-20mA&customized G1/2&customized
-
Sanitary pressure transmitter 12-36VDC 4-20mA&customized 50.5Chuck
-
Digital display pressure transmitter
-
High temperature pressure transmitter
-
Integrated differential pressure transmitter
-
Cable type pressure transmitter 12-36VDC 4-20mA&customized 1/2NPT
Popular Searches
- transmitter
- pressure transducer
- pressure transmitter
- flow transmitter
- gauge pressure transmitter
- smart pressure transmitter
- Measuring Instruments Transmitter
- Pressure Transmitters
- Differential Pressure Transmitter
- Pressure Sensor Transmitter
- Industrial Pressure Transmitter
- Silicone Pressure Transmitter
- Water Pressure Transmitter
- Oil Pressure Transmitter
- Absolute Pressure Transmitter
- Diaphragm Pressure Transmitter
- Display Pressure Transmitter
- Differential Pressure Sensor
- Pressure Transducer Sensor
- hart
- humidity sensor
- smart sensor
- temperature transmitter
- liquid in pressure gauge
- differential pressure transducer
- hart pressure transmitter
- Pressure Transducer Transmitter
- Pressure Gauge Transmitter
- Air Pressure Transmitter
- Pressure Sensor Transducer Transmitter
Recommended Products
- 4-20mA Output Signal HART Communication EJX110A YOKOGAWA Differential Pressure Transmitter
- YOKOGAWA EJX110A Differential Pressure Transmitter EJX110A-JMSWG-919EJ/KS21
- 3051CD Pressure Transmitter 3051 Differential Pressure Transmitter 4-20ma
- YOKOGAWA EJA110E EJA120E Pressure Transmitter Differential Pressure Indicator Transmitter
- EJA110E Accurate Differential Pressure Transmitter Eja110e-Dms4j-912db
- EJA430E Pressure Transmitter With FOUNDATION Fieldbus And PROFIBUS PA Compatibility
- EJA130E Differential Pressure Transmitter Differential Pressure Transmitter
- Emerson Rosemount 3051 Wireless Differential Pressure Transmitter For Level Measurement
- Absolute and Gauge Pressure Cerabar PMC21 Endress+Hauser PMC21 - AA1A1CBWBJA
- Absolute and Gauge Pressure Cerabar Endress+Hauser PMC21 Pressure Transmitter Sensor
- Hydrostatic inputlevel gauge
- 2088 industrial pressure transmitter domestic self-developed ky3002Gp
Find Similar Products By Category
- Electrical & Electronics > Transmitter > Pressure Transmitter

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
feng
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile