DP 510 - Portable dew point meter with third-party sensor
- T/T
You May Like
-
DS 400 Set - Stationary dew point measurement in compressed air systems
-
FA 500 - Dew point sensor with integrated display and alarm relay
-
FA 505 - Dew point sensor for OEM applications
-
FA 550 - Dew point sensor in robust die-cast aluminum housing
-
FA 510/515 - Dew point sensor for adsorption dryers
-
FA 515 - Dew point sensor for refrigeration dryers
Product Details
Brand Name | CS | Place of Origin | Germany | |
Model Number | DP 510 |
Product Description
DP 510 - Portable dew point meter with third-party sensor
and integrated data logger. With DP 510 it is possible to performing all measuring tasks with one instrument. It disposes of all functions of DP 500 and has an additional freely assignable sensor input. Additionally to the internal dew point measurement one further optional sensor can be connected. So you could meet nearly all industrial measuring tasks.
Main features of our portable dew point meter DP 510:
Separate pressure measurement
Dew point distance via external temperature sensor
Compressed air consumption measurement
Active power in kWh/kW
4lnstallation and measurements
We recommend the use of a measuring chamber!
4.1 Measurement with measuring chamber, connection via plug nipple
1.Preparation of the measuring point
Let compressed air flow off at the sampling point beforemeasurement in order to remove condensate and particles.This avoids a soiling of DP 500/DP 510 and the measuringchamber.
Stagnant air leads to long adjustment times.
lf condensate occurs at the measuring point, please check thecompressed-air conditioning before measurement.
2.Switch on DP 500/DP 510 and wait until the initializationhas been finished.
Please observe the chapter "operation".
3.Connect the measuring chamber screwed onto DP 500/DP510 with the plug nipple coupling of the measuring point
4.Wait until the value in the display of DP500/DP510 hasstabilized. Depending on the position of the measuring pointthis may take up to 15 minutes.
5. Disconnect the measuring chamber from the plug nipplecoupling of the measuring point after measurement. Switch offDP500/DP 510 if you do not want to carry out further
measurements.
4.2Measurement without measuring chamber, connection via external thread G1/2""
1.Preparation of the measuring point
Make sure that the measuring point is depressurized.Please check the sampling point before measurement.
lf condensate occurs at the measuring point you should checkthe compressed-air conditioning before measurement.
2.Screw the DP 500/DP 510 (without mounted measuringchamber) into the measuring point (with internal thread G1/2").For mounting you should use the spanner flat (sw27)!
3.Switch on DP 500/DP510 and wait until the initializationhas been finished.
Please observe the chapter "operation".
4.Charge the measuring point slowly with pressure.
5.Wait until the value in the display of DP 500/DP 510 hasstabilized.Depending on the position of the measuring pointthis may take up to 15 minutes.
6.After measurement please drain the pressure slowly from themeasuring point.
7.Remove DP 500/DP 510 from the measuring point. Fordemounting the instrument, you should use the spanner flat(sw 27)!
8. If you do not want to carry out further measurements pleaseswitch off DP 500/DP510.
4.3Dew point measuring at synthetic granules -dries
Synthetic granules-dries usually work with a slight positivepressure in the millibar range.Use in this application, with a
Air input
slight excess pressure, the measuring chamber for syntheticgranules dryer (Order No.0699.3490).
Since the air temperature in the synthetic granules dryer is alsovery high, the air supply from the synthetic granules dryer to themeasuring chamber via a correspondingly long Teflon tube
(recommended length of 1-2 m), which serves as a coolingsection. Note that the measured air temperature in the DP500if possible remains below 40 ° C, otherwise please use a longerTeflon tube as a cooling section.
Air output
The supply of air into the measuring chamber via port A (airinput).On the air output, a Teflon tube is connected with alength of at least 80 cm.This prevents the back flow of humidambient air back into the measuring chamber.
Contact Us
- Dekemeng Process Control (Wuhan) Co.,Ltd.
Product Categories
Transmitter | Level Transmitters | Flow Meters | radar level sensors |
Accessories | Sensors |
New Products
-
Kfd0-SD2-Ex2.1045 Solenoid Driver
-
Relay Module 100% New Kfd0-RO-Ex2
-
Kfd2-Crg2-Ex1. D 24 V DC Supply
-
Strain Gauge Converter Kfd2-Wac2-Ex1. D
-
Kfd2-Crg2-Ex1. D 1-Channel Isolated Barrier
-
Rosemount 3051S Differential Pressure Transmitter
-
Rosemount 3051L Level Transmitter
-
Rosemount 8800D Vortex MultiVariable Flow Meters
-
Rosemount 3051SFA Annubar Flow Meter
-
Micro Motion CNG050 Coriolis Flow Meter
-
rosemount 3100 series ultrasonic level transmitter
-
Rosemount 3300 series Guided Wave Radar Level Transmitter
Popular Searches
- lab equipment
- Infrared Thermometer
- testing equipment
- Moisture Meter
- gas instrument
- humidity meter
- moisture detector
- analyzer
- temperature humidity meter
- water content tester
- Water Content Analyzer
- digital hygrometer
- Point Tester
- water content instrument
- dew point instrument
- dew point analyzer
- lab equipment
- Infrared Thermometer
- testing equipment
- Moisture Meter
- Water Meter
- gas meter
- gas instrument
- Test Meter
- humidity meter
- moisture detector
- Grain Moisture Meter
- analyzer
- temperature humidity meter
- humidity sensor
Recommended Products
- MOOG Servo Valve D661-4651
- Danfoss Orbital motor OMS160 151F0503
- Danfoss Orbital motor OMR160 151-0714
- Danfoss Orbital motor OMT200 151B3001
- AGV Drive Wheel for Semiconductor Transport in Cleanroom
- HAGGLUNDS High pressure variable pump SPM 750-SR-X-EFX-R902470019
- HAGGLUNDS High pressure variable motor CBP840-840 -SA0VH-0C- 00
- HAGGLUNDS High pressure variable pump SP500SR-V-EP2433970
- HAGGLUNDS High pressure variable motor CA210210SA0N000200
- HAGGLUNDS High pressure variable motor CB 0560 0560 CA0N00 00 00
- HAGGLUNDS High pressure variable motor CB02800280SA0N00
- HAGGLUNDS High pressure variable motor CBM 2000 1200 SA0N0C 01 05
Find Similar Products By Category
- Manufacturing & Processing Machinery > Metallic Processing Machinery > Metal Processing Machinery Parts

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile