- Acrel Electric Co., Ltd
-
Shanghai, China
- Main products: Hall Sensor, Split Core Current Transformer, AC Energy Meter, DC Energy Meter, IoT Wireless Power Meter, PV/Solar Inverter Energy Meter, Data Center Power Meter, Wireless Temperature Monitoring System and Sensors, Medical IT Products, City Utility Tunnel Moter Protector, Electrical Insulation Safety Products, Energy Quality Improvement
Home > Products > hospital IT insulation monitor > Hospital Insulation Monitoring Device AIM-M10 for Operating theater IEC 61557-8 approved
Hospital Insulation Monitoring Device AIM-M10 for Operating theater IEC 61557-8 approved
Negotiable
1 (Min.Order)
- 1000 per Month
- T/T Credit Card
You May Like
-
Acrel ICU/CCU ground-fault detection and location solutions AIL150-4 IEC Approved EDS416-D
-
Hospital isolated power distribution system for medical Group II Location protecting personnel and equipment
-
Acrel 300286 medical IT system insulation monitoring device AIM-M200 for ICU/CCU
-
Acrel 300286 medical IT isolated power supply monitoring system ICU insulation monitor AIM-M100
-
Hospital ICU/CCU Insulation Monitoring Device AIM-M100 IEC Cert
-
Acrel Medical IT System Insulation monitoring device for medical location with insulation system
Product Description
AIM-M10 series insulation monitor
Product Description
Characteristic
AIM-M Series insulation monitor is a high-performance insulation monitoring device,and is dedicated to medical IT systems. It is used to monitor the state of the ground insulation.When the system has an insulation fault,it can send out alarm signals in time.It helps staff to deal with the actual situation.The product is with extensive display and alarm indication function,user-friendly,and easy to operate.
Function
1. real time monitor and fault alarm of the ground insulation resistance,
2. transformer load current and transformer winding temperature of the monitored IT system,
3. be used with insulation fault locator, remotely starting fault-locating and displaying locating results when there are insulation faults,
4. real-time monitor the line disconnection fault, temperature sensor disconnection fault and the functional grounding line disconnection fault of the monitored system, and give the alarm indication within 2S after the fault . occurs,
5. relay alarm output, LED alarm indication and other faults indication functions,
6. used for centralized alarm and display instrument, test signal generator, insulation fault locator and upper computer management software communications, and can monitor the operation status of IT system in real time.
7. Events logging function, which can record alarm occurrence time and fault type and is convenient for operation personnel to analyze the operation conditions of system and promptly eliminate the faults.
2. transformer load current and transformer winding temperature of the monitored IT system,
3. be used with insulation fault locator, remotely starting fault-locating and displaying locating results when there are insulation faults,
4. real-time monitor the line disconnection fault, temperature sensor disconnection fault and the functional grounding line disconnection fault of the monitored system, and give the alarm indication within 2S after the fault . occurs,
5. relay alarm output, LED alarm indication and other faults indication functions,
6. used for centralized alarm and display instrument, test signal generator, insulation fault locator and upper computer management software communications, and can monitor the operation status of IT system in real time.
7. Events logging function, which can record alarm occurrence time and fault type and is convenient for operation personnel to analyze the operation conditions of system and promptly eliminate the faults.
Specification
Quotation
Model | Function | FOB Shanghai(USD) | Wholesale price | ||
AIM-M10 | Insulaton Monitoring;Auxiliary power supply AC220V | 1244 | Please contact us in detail. We can offer you the best price. | ||
AIM-M100 | Insulaton Monitoring;Auxiliary power supply AC220V | 1617 | |||
AIM-M200 | Insulaton Monitoring; Auxiliary power supply DC24V Supports the insulation fault location | 2032 |
Model Selection Description
AIM-M100 auxiliary power supply is AC220V,the product does not have insulation fault location.AIM-M200 auxiliary power is DC 24V.It has all the monitoring functions of AIM-M10 and AIM-M100 products,it also supports the insulation fault location.If you need insulation fault location,please choose AIM-M200.The positioning function can also be turned off through the menu.Certificate
we supply full products of this cabinet from current transformers, meters to cabinets.
Application programme-ICU/CCU
Packing & Delivery
Company Profie
Contact Us
- Acrel Electric Co., Ltd
- Contact nameShelly Zhang Chat Now
- Phone86-21-18702111813
Product Categories
New Products
-
Medical insulation monitoring devices AIM-M100 monitor the insulation resistance of IT systems
-
Acrel Isolated Power Monitor System for Hospital Isolated Power System
-
Acrel AID120 Medical isolation Alarm and display device for medical isolated power system
-
Acrel ASG100 Signal Generator
-
Acrel AID150 Alarm And Display Device for Medical IT System
-
Acrel AID200 Medical isolation Nurse Station Alarm device for Hospital Isolated Power System
-
AMC16-DETT Base Station DC Energy Meter
-
Multi circuits 4G wireless dc energy meter ADW350WD/4G 50A/100A input include 3 Hall sensor
-
3 circuits dc energy meter ADW350WD 100A input with 3 Hall sensor for base station
-
Acrel AMC16-DETT multi channels dc power metering solution for telecom tower station
-
Acrel 6 circuits DC energy meter with Modbus protocol for telecom base staion CE approval
-
DC digital watt power monitoring meter for EVS Charging station CE certificate
-
Acrel multi tariff DC panel energy meter PZ72L-DE/F for dc electric vehicle charging station
-
Acrel digital dc panel power analyzer meter PZ72L-DE for dc charging pile
-
Acrel din rail 2 circuit DC watt power meter for 2 channel dc electric vehicle charging pile
-
Acrel rail type 2 circuit DC energy meter for 2 channel charging pile
-
DC power meter for charging pile energy management.
-
Acrel 6 channel dc energy power meter AMC16-DETT
-
Acrel 6 channel measure tower base station dc energy meter AMC16-DETT
-
Acrel solar dc watt-hour energy meter for telecom station
-
Din Rail Digital DC Energy Power Meter for charging stations
-
Din Rail Digital Electric DC Energy Power Meter for solar system
-
Acrel din rail-mounted solar dc energy meter for pv power station
-
Din rail mounted DC power meter for solar pv monitoring DJSF1352-RN
Popular Searches
- power transformer
- Distribution Service
- current transformer
- power transformers
- High Frequency Transformer
- Electrical Transformer
- energy saver device
- led transformers
- step up converter
- Ac Drive Converter
- Frequency Drive Converter
- lightning conductor
- Copper Lightning Rod
- electronic transformer
- Lighting Transformers
- toroidal transformer
- auto transformer
- current transformer inductor
- voltage transformer
- Control Transformer
- Power Supply Transformer
- Led Lighting Transformer
- Waterproof Transformer
- Electric Transformer
- Low Frequency Transformer
- Flyback Transformer
- Core Transformer
- pot & kettle
- Output Inductor
- Power Distribution Equipment
Recommended Products
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now
Acrel Electric Co., Ltd
AIBot OnlineThis conversation is AI-generated. Contact manufacturer before transaction to confirm info.
-
Shelly Zhang
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile