- Main products: Series resonance test device, Transformer tester, Circuit breaker, switch tester, High Voltage Insulation Equipm, Relay Protection Products, Cable and cable fault tester, Arrester and Insulator Test In, SF6 Test Instrument, Oil Testing Instrument, DC System and Battery Test Ins, Ground/Insulation Resistance T, Power Energy Analyzer, Power Energy Analyzer
Home > Products > Transformer tester > TKRZ-5001 Transformer Winding Deformation Tester
TKRZ-5001 Transformer Winding Deformation Tester
- T/T Other
You May Like
Product Details
Brand Name | GDMK | Place of Origin | China | |
Model Number | TKRZ-5001 |
Product Description
TKRZ-5001 Transformer Winding Deformation Tester, based on the measurement of the characteristic parameters of the transformer's internal windings, adopts the internal fault frequency response analysis that is currently being developed in developed countries in the world.
(FRA) method, can make accurate judgments on the internal fault of the transformer. After the transformer is designed and manufactured, its coil and internal structure are determined, so for a multi-winding transformer coil
If the voltage level is the same and the winding method is the same, the corresponding parameters (Ci, Li) of each coil should be determined. Therefore, the frequency domain characteristic response of each coil is also determined, and the corresponding three-phase line
There is a certain degree of comparability between the frequency maps; the transformer has a short circuit between turns and phases during the test, or a collision occurs during transportation, which causes the relative displacement of the coil, and the relative displacement of the coil during the operation.
Under short-circuit and fault conditions, the deformation of the coil due to electromagnetic tension will change the distribution parameters of the transformer winding. Then affect and change the original frequency domain characteristics of the transformer, that is, the frequency response occurs
Amplitude changes and resonant frequency shifts, etc. The transformer winding tester developed based on the response analysis method is such a novel non-destructive testing equipment for transformer internal faults. It works for
63kV~500kV power transformer internal structure fault detection.
The transformer winding deformation tester is to quantify the response changes of the internal winding parameters of the transformer in different frequency domains, according to the magnitude of the change, the amplitude, area and frequency of the frequency response change.
To determine the degree of change in the internal windings of the transformer according to the changing trend of the transformer, and then determine whether the transformer has been severely damaged and whether it needs to be overhauled according to the measurement results. For running
Regardless of whether the frequency domain characteristic map is saved in the past, the fault degree can also be judged by comparing the difference of the characteristic map between the faulty transformer coils. Of course, if you save
A set of original winding characteristic diagrams of the transformer can provide a more accurate and powerful basis for the operation status of the transformer, post-accident analysis, and maintenance and repair.
Contact Us
- Wuhan Guodian Mingke Electric Co., Ltd.
- Contact namewangchengfeng Chat Now
Product Categories
New Products
-
TKZKD vacuum switch vacuum tester
-
TKKGG-H high and low voltage switchgear energization test bench
-
LBQ-III Leakage Protector Tester
-
TKAM-500A DC circuit breaker ampere-second characteristic tester
-
TKGK-HC high voltage switch comprehensive characteristic tester
-
TKCZ-II Isolating switch contact finger pressure tester
-
TKHL-SC handheld loop resistance tester
-
TKJB single-phase relay protection tester
-
TKJB-703 three-phase microcomputer relay protection tester
-
Automatic Multifunctional Degassing Oscillation Tester
-
HZ6000 Wireless High Voltage Multifunction Phasing Stick
-
Battery Charge And Discharge Machine Capacitance Test Equipment
Popular Searches
Recommended Products
- Bently Nevada 330130-085-00-CN
- Bently Nevada 21000-34-05-15-056-04-02
- Bently Nevada 330910-01-07-10-01-00
- Bently Nevada 330851-02-000-050-50-00-05
- Bently Nevada 330103-00-17-10-02-CN
- Bently Nevada 330103-01-06-05-02-05
- Bently Nevada 330103-00-04-10-12-00
- Bently Nevada 330103-00-21-05-11-05
- Bently Nevada 330101-00-25-05-02-05
- Bently Nevada 330903-00-04-05-02-00
- Bently Nevada 330101-00-24-05-02-00
- Bently Nevada 330104-00-12-10-02-05
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
wangchengfeng
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile