- Wuhan Guodian Mingke Electric Co., Ltd.
- Main products: Series resonance test device, Transformer tester, Circuit breaker, switch tester, High Voltage Insulation Equipm, Relay Protection Products, Cable and cable fault tester, Arrester and Insulator Test In, SF6 Test Instrument, Oil Testing Instrument, DC System and Battery Test Ins, Ground/Insulation Resistance T, Power Energy Analyzer, Power Energy Analyzer
Home > Products > Transformer tester > Loss Tester Intelligent Tg Dielectric Meter
Loss Tester Intelligent Tg Dielectric Meter
- T/T Other
You May Like
Product Details
Brand Name | GDMK | Place of Origin | China | |
Model Number | Transformer Tester |
Product Description
Overview:
Loss Tester Intelligent Tg Dielectric Meter is a kind of instrument with high precision fully automatic measuring the dielectric loss tangent and capacitance of various high voltage electrical equipments in the power plants and substations. The adoption of frequency conversion technology could ensure the accurate measurement in the interference of strong electric field.
Main technical parameters:
1.High voltage output: 0.5~10kV
Increasing by 500V for each level, a total of 20 levels, capacity: 1500VA
2. Accuracy: tgδ: ± (reading *1.5% +0.06%)
Cx: ± (reading * 1.5% +5 PF)
3. Resolution: tgδ: 0.001% Cx: 0.001pF
4. Measuring range: 0.001% Internal high pressure : 3PF ~60000PF/10KV 60PF~1μF/0.5KV External high pressure: 3PF ~1.5μF/10KV 60PF~30μF/0.5KV 5.Power supply: AC 220V ± 10% 50/60 ± 1Hz 6. Measuring method: a.single frequency: 45(45Hz measuring)、50(50Hz measuring)、55(55Hz measuring)、60(60Hz measuring)、65(65Hz measuring) b.different frequency: 50D(45Hz/55Hz measure each time) 60D(55Hz/65Hz measure each time) Automatic frequency conversion 7. Harmonic adaptation: ≤ 3% 8. Application condition: -15 ℃-50 ℃ Relative humidity <80% 9. Dimension: 460 (L) × 345 (W) × 345 (H) 10. Weight: 35 kg Precautions: 1.The instrument is only used on power-off equipment. The grounding terminal should be connected to the grounding network reliably. 2.The instrument should be used in spacious, safe and reliable place. 3.The equipment under test is shifted to the maintenance state if the high-voltage lead is disconnected from operation state and could be cleaned. 4.The instrument could be tested only after good initial insulation test so as to avoid the poor insulation of equipment under test causing the damage of the instrument during the pressing process.
Contact Us
- Wuhan Guodian Mingke Electric Co., Ltd.
- Contact namewangchengfeng Chat Now
Product Categories
New Products
-
Transformer Control Box
-
Transformer Standard Current Tester
-
Transformer Standard Voltage Tester
-
CT PT Load Box
-
Transformer Load Box
-
Ground Continuity Tester
-
Ground Resistance Test System
-
Earth Ground Resistance Tester
-
Insulation Resistance Tester With Absorption Ratio
-
Insulation Resistance Tester
-
3 Phase Handheld Power Quality Analyzer
-
Three-phase Standard Power Source
Popular Searches
- resistance tester
- lab equipment
- test equipment
- multimeter
- test machine
- hot stamping
- insulation tester
- test
- resin ribbon
- voltage tester
- high voltage tester
- testing transformer
- oil dielectric strength tester
- transformer test equipment
- dc resistance meter
- dc resistance test
- factor tester
- insulating oil tester
- ac dc hipot tester
- tan delta tester
- power factor tester
- transformer turn ratio tester
- dielectric loss tester
- load tester
- winding deformation tester
Recommended Products
- UFC762AE101 3BHE006412R0101 Control System DCS Spare Parts Spot Goods
- DSMB-01C Spare Parts of Inverter Power Boards for Frequency Converters Fast Delivery Power
- RS-FS-9001 362A1052P404 Spiral Joint Fluid Control System
- Vibro-meter VM600 RPS6U 200-582-200-011 Vibration Sensor Detection System
- TRICONEX 4351B Control Module
- FOXBORO FCP270 P0917YZ Controller Module
- H201Ti Monitor Industrial Control DCS System
- UNITROL 1020 UNS0119A-Z V1 3BHE030579R0003 Excitation Static Controller
- Vibro-meter 200-560-000-018 200-560-101-015 VM600 IOC4T Module/Controller
- EMERSON VE3008 CE3008 KJ2005X1-MQ1 12P6381X042 Industrial Automation System Module
- ALSTOM N897164624A Module/controller Redundancy Positioning System
- ALSTOM N895314513L Data Acquisition Module
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
wangchengfeng
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile