Fume hood is one of the important safety equipment in laboratory , it is an effectient partial ventilation . Proper selection ,installation ,operation and maintenance ,the fume hood can keep users away from chemical reagents and other harmful substances.at the same time ,if a fire or explosion occurs,the fume hood will provid adequate security .
BOKA provide fume cupboards in standard width of 1200,1500,1800mm . however we also design custom-tailored solutions . our designed fume hood have benchtop fume hood ,low-height fume hood,low level fume hood and walk in fume hood .Worktop and interior lining are configured commensurate with the associated details ,gases and liquids used ,vapours and aerosols.
Standard fume hood
Technical data
Width (mm)
1200
1500
1800
External dimensions (mm)
1200*850*2350
1500*850*2350
1800*850*2350
Internal workspace (mm)
950*650*1100
1250*650*1100
1550*650*1100
Base cabinet (mm)
1200*850*850
1500*850*850
1800*850*850
Max Exhaust volume (m3/h )
1200
1500
1800
Min Exhaust volume(m3/h )
308
400
480
Face velocity speed
0.5m/s
Material
Steel ,PP ,stainless steel for your option
Worktop
Epoxy resin ,phenolic resin ,ceramic ,PP ,stainless steel for your option
Multi-function fume hood
Features
1. The fume hood monitor LCD display screen,real0time display of the face velocity speed and control valve state ,to remind the user the fume hood’s usage state .
2. Fume hood exhaust air valve adjustable ,also maintain the face velocity speed of 0.5±15% .under the condition that the specificed exhaust volume and average face velocity speed are maintained at 0.5m/s , the resistance of the fume hood is less than 70 pascals .the change of the average face velocity speed only occurs when the sash is moving .once the sash is moved to a certain position . the average face velocity speed will restored to 0.5m/s ,and the response speed is less than 1.5s .
3. When the fume hood is closed ,the air volume valve shall maintain the minimum exhaust volume of the fume hood to meet the actual requirements .
4. If the face velocity speed of the fume hood is less than 0.25m/s ,an orange LED flash will appear,indicating the user’s attention .at the same time ,it can set the alarm value of the face velocity speed too low,such as 0.2m/s . and when the face velocity speed is lower than the set value ,the sound and light alarm will be generated .
5. When the user come close to the sash ,the sash will go up automatically ,when go away ,it will go down automatically
6. When put the finger or barrier under the sash ,it will stop
If interesting,please click the picture for more details ! ! !
Click here for more details ! ! !
♥ ♥ ♥ Inquiry Now, Click Here!!!♥ ♥ ♥
Certifications
Contact information
Company Profile
Guangzhou Boka Lab System Tech. Co., Ltd.
Our company is a manufacturer of laboratory furniture with well-equipped testing facilities and strong technical force. We have 7 year export experience of lab furniture and 12 year experience of lab engineering system construction accumulation.We provide one-line professional service of lab planning & designs, lab furniture manufacture, lab engineering system construction, installation, lab information management system and lab turnkey project.