Brand Name | Drawell | Place of Origin | Shanghai, China | |
Model Number | DW-AAS-120A | Size | 1020*490*540mm, 420*420*460 mm | |
Weight | 80Kg/ 50Kg | Wavelength Range | 190-900nm | |
Focal Length | 277mm |
Product Description
Flame/Graphite Furnace Atomic Absorption Spectrophotometer
DW-AAS-110A/120A/130A
FEATURES:
Innovated Rich oxygen air-acetylene flame analysis technique (DW-AAS-110A)
The patented flame analysis technique adopting rich oxygen air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses, such as Ca, Al, Ba, W, Mo, Ti, V, etc. Flame temperature is continuously adjustable between 2300-2950℃, which makes it possible to choose the best atomization temperature for different elements. It features easy operation, low analysis cost and wide flame AAS analytical range. Rich oxygen flame is will not pollute the environment and is not harmful to human bodies. It’s a break-through in flame AAS analysis.
Integrated flame/graphite furnace atomization system, changeable with flame emission burner
· Automatically controlled changeover of the integrated flame and graphite furnace atomizer featuring easy operation and time saving eliminates human labor.
· A flame emission burner head can be installed to perform flame emission analysis to Alkali metals as K, Na etc. (DW-AAS-110A/120A)
Accurate fully automated control system
· Automatic multi-lamp turret, automatic adjustment of lamp current and optimization of light beam position. · Automatic wavelength scanning and peak picking
· Automatic spectral bandwidth changing
· Automatic changeover between flame and graphite furnace operation, automatic optimization of position parameters, and automatic ignition
Reliable fully automatic graphite furnace analysis
· Adopting FUZZY-PID and dual curve mode light-controlled temperature control technique, temperature auto-correction technique, ensures fast heating, good temperature reproducibility and high analytical sensitivity. The temperature control accuracy is less than 1%.
· Graphite furnace with pneumatic control and pressure lock ensures constant pressure and reliable contact.
Perfect safety protection measures
· Alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system;
· Alarm and protection function to insufficient carrier gas and protective gas pressure, insufficient cooling water supply and over-heating in graphite furnace system.
Advanced and reliable electronic design
· Adopting large-scale programmable logic array and Inter I2C bus technology
· European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system.
Easy and practical analysis software
· Easy-to-use AAS analysis software is made under Windows operating system, realizing fast parameter setting and optimization.
· Automatic display of measured data, automatic calculation and analytical result automatic print out.
SPECIFICATIONS:
Main Specification |
Wavelength range |
190-900n |
Wavelength accuracy |
±0.25nm |
|
Resolution |
Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%. |
|
Baseline stability |
≤0.004A/30min |
|
Background correction |
The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times. (only for WFX-110A/120A) |
|
Hollow Cathode Lamps |
Lamp turret |
6-lamp turret (DW-AAS-110A/120A), 4-lamp turret (DW-AAS-130A) Auto-alignment, fully automated scan and peak-picking. |
Lamp current adjustment |
Automatic adjustment and display. Wide pulse current: 0~25mA, Narrow pulse current: 0~10mA |
|
Lamp power supply mode |
400Hz square wave pulse 100Hz Narrow square wave pulse + 400Hz wide square wave pulse (DW-AAS-110A/120A) |
|
Optical System |
Monochomator |
Single beam, Czerny-Turner design grating monochromator |
Grating |
1800 l/mm |
|
Focal length |
||
Blazed Wavelength |
250nm |
|
Spectral Bandwidth |
0.1nm, 0.2nm, 0.4nm, 1.2nm automatic change. |
|
Flame Atomizer |
Burner |
10cm single slot all-titanium burner |
Spray chamber |
Corrosion resistant all-plastic spray chamber. |
|
Nebulizer |
High efficiency glass nebulizer with metal sleeve, sucking up rate: 6-7mL/min |
|
Provided with DW-AAS-110A/120A |
||
Graphite Furnace |
Temperature range |
Room temperature~3000ºC |
Heating rate |
2000℃/s |
|
Graphite tube dimensions |
28mm (L) x 8mm (OD) |
|
Characteristic mass |
Cd≤0.8 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g |
|
Precision |
Cd≤3%, Cu≤3%, Mo≤4% |
|
Detection and Data Processing System |
Detector |
R928 Photomultiplier with high sensitivity and wide spectral range. |
Software |
Windows operating system |
|
Analytical method |
Working curve auto-fitting; standard addition method; automatic sensitivity correction; automatic calculation of concentration and content. |
|
Repeat times |
Maximum 20 times of repeat measurement, automatic calculation of mean value, standard deviation and relative standard deviation. |
|
Multi-task function |
Sequential measurement of multi-elements in one sample |
|
Condition reading |
With model function |
|
Result printing |
Measurement data and final analytical report printout, editing with Excel. |
|
Standard RS-232 serial port communication |
||
Characteristic Concentration and Detection Limit |
Normal Air-C2H2 flame |
Cu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L; |
Oxygen-rich Air-C2H2 flame |
Ba: Characteristic concentration ≤ 0.22mg/L Al: Characteristic concentration ≤ 0.4mg/L (for WFX-110A) |
|
Function Expansion |
Hydride vapor generator can be connected for hydride analysis. |
|
Dimensions and weight |
1020 (L) × 490(W) × 540 (H) mm (main unit), unpacked 80kg 420 (L) × 420 (W) × 460 (H) mm (graphite furnace), unpacked 50kg |
Contact Us
- Chongqing Drawell Instrument Co., Ltd.
Product Categories
New Products
-
Nanodrop Spectrophotometer Price For Lab
-
Wholesale Nano Spectrophotometer For DNA Testing
-
DNA Testing Instrument Equipment Machine MD2000
-
Wholesale DNA Protein Testing Equipment Manufacturer
-
DW-K5500Plus Micro Volume Spectrophotometer
-
Nanodrop Spectrophotometer Price For Lab
-
Fourier Transform Infrared Spectrometer Machine Price
-
Fourier Transform Infrared Spectrometer
-
Fourier Transform Infrared Spectrometer Price 530A
-
Gold Testing Handheld XRF Analyzer Machine
-
Handheld XRF Metal Alloy Analyzer Truex 860
-
Alloy Analyzer Handheld XRF Truex 860
-
xrf machine/ gold xrf analyzer TrueX ROHS
-
Handheld xrf gold analyzer spectrometer price TrueX 900
-
Handheld XRF Metal Analyzer TrueX Gold
-
Drawell Metal Analysis Direct Reading Spectrometer
-
Professional Inductively Coupled Plasma (ICP) Emission Spectrometer
-
Drawell ICP-AES Atomic Emission Spectrometer DW-TY-9900
Popular Searches
- spectrophotometer
- infrared spectrometer
- spectrometer
- vis spectrophotometer
- photometer
- visible spectrophotometer
- Fluorescence Spectrophotometer
- Double Beam Spectrophotometer
- Uv Spectrophotometer
- Single Beam Spectrophotometer
- Lab Spectrophotometer
- Scanning Spectrophotometer
- Portable Spectrophotometer
- Grating Spectrophotometer
- Aas Spectrophotometer
- Spectrometers
- optical emission spectrometer
- metal spectrometer
- Handheld Spectrometer
- Direct Reading Spectrometer
- Portable Spectrometer
- Spectrophotometer Portable Spectrometer
- Spectrum Direct Reading Spectrometer
- Ir Spectrometer
- Spark Direct Reading Spectrometer
- jewelry tester
- jewelry analyzer
- spectrometer for metal analysis
- spark spectrometer
- optical spectrometer
Recommended Products
- Personal Noise Dose Meter DB22-600DOS
- Impulse Sound Level Meter DB30-6228I
- 【High Precision】Aike F - 7000 Ore Spectrometer, capable of analyzing all elements from titanium to plutonium, dual - purpose for mines and environmental protection
- Aike Handheld XRF Spectrometer, Alloy Analyzer, for rapid detection of metal components. It can accurately and non - destructively identify 304/316 stainless steel, especially designed for industrial sites.
- i-CHEQ Handheld Raman Spectrometer for Drugs/Explosives/Chemicals Detection | 20s Fast ID | GPS+Cloud IoT | 21 CFR Part 11 & cGMP Certified
- Element content analysis of precious metal detector, detection of gold purity content
- Soil Spectrometer Soil Spectroscopy Portable Soil Spectrometer Hand - held Soil Spectrometer Visible - Near Infrared (VIS - NIR) Soil Spectrometer Soil Nutrient Spectrometer Soil Organic Matter Spectrometer
- Ore Spectrometer XRF Spectrometer Handheld Spectrometer Portable Spectrometer Mineral Spectrometer NIR Spectrometer Spectrometry Technology Ore Analysis
- Portable spark direct reading spectrometer, desktop spark direct reading spectrometer, CCD detection, multi-channel spark direct reading spectrometer, high-resolution spark direct reading spectrometer, non-ferrous metals
- Water quality detector, water pollution detection, environmental detection, heavy metal detection
- VOC gas detector, petrochemical atmosphere environment detection, indoor environment detection, sulfide gas detection
- Raman spectrometer analyzer, detector, chemical analysis, jewelry identification, drug identification, explosive identification
Find Similar Products By Category
- Instruments & Meters > Optical Lens & Instrument > Spectrometer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile