Home > Products > Smart Motor Protector > Acrel ARD2-250 timeout startup, over load, unbalance, blocking, short circuit 55KW 75KW 90KW 110KW 132KW motor protector
Acrel ARD2-250 timeout startup, over load, unbalance, blocking, short circuit 55KW 75KW 90KW 110KW 132KW motor protector
- 1000 Set / Sets per Month
- T/T Credit Card
You May Like
-
Acrel ARD2-25 timeout startup, over load, unbalance, blocking, short circuit 3KW 5.5KW 7.5KW 11KW motor protector
-
Acrel ARD2-5 timeout startup, over load ,phase failure, unbalance, blocking, short circuit 0.12KW 0.37KW 0.55KW motor protector
-
Acrel PZ96-AI3/JC ac three phase led programmable digital current panel meter optional over under curret alarm rs485 modbus
-
Acrel PZ96-AI3/K ac three phase led programmable digital current panel meter with 4 di/2do
-
Acrel PZ96-AI3/M ac three phase led programmable digital current panel meter with one analog output
-
Acrel PZ96-AI3/MC ac three phase led programmable digital ammeter optional one analog output rs485 modbus
Product Details
Brand Name | Acrel | Place of Origin | Jiangsu, China | |
Model Number | ARD2 |
Product Description
1,Overview
ARD series intelligent motor protector (hereinafter referred to as protector) can perform various conditions such as start timeout, overload, phase failure, unbalance, underload, ground/leakage, blockage, short circuit and external fault during motor operation. Protection, and SOE fault event recording function, convenient for on-site maintenance personnel to find the cause of the fault. Suitable for coal, petrochemical, smelting, electric power, ships, and civil construction. The protector has RS485 remote communication interface, DC 4 ~ 20mA analog output, and PLC, PC and other control machines form a network system. Remote monitoring of motor operation.
2,Model Description
l ARD2(L) intelligent motor protector
Table 4 Design serial number
Design serial number | Specification | Design serial number | Specification |
2 | Digital tube display | 2L | LCD |
Table5 Rated current
Protector rated current(A) | Ratio setting | Transformer primary side turns | Setting current Is range(A) | Motor Power(kW) |
1 | Need to set | 5 | 0.1~999.9 | 0.12~440 |
5 | 1 | 0.1~999.9 | 0.12~440 | |
1.6 | No need to set | 1 | 0.4~1.6 | 0.12~0.55 |
6.3 | 1 | 1.6~6.3 | 0.75~2.2 | |
25 | 1 | 6.3~25 | 3~11 | |
100 | 1 | 25~100 | 15~45 | |
250 | 1 | 63~250 | 55~132 | |
800 | 1 | 250~800 | 160~440 |
Table 6 Additional features
Additional features | Code | Additional features | Code |
Communication Interface | C | 2 switch input; 1 relay output (programmable 3) | K |
Leakage Protection | L | SOE record | SR |
4~20mA analog output | M | Alarm output (programmable 2) | J |
Note: 1. When the additional function is equipped with leakage protection L, it is necessary to purchase zero-sequence transformers with different apertures according to the actual current.
Cautions
1.For the primary circuit, three-phase current threading direction shall keep consistent, or else, the ground protection will be in error.
2.When the protector is equipped with ground/leakage protection function, the protector wire from the leakage transformer shall be shielded conductor, or else, the measured data may be incorrect.
3.The rated current (P055) of the protector shall be set rationally. If the set value is less than the normal rated working current, the motor may not start normally; if the set value is more than the normal rated working current, the protector cannot provide the normal protection in case of motor fault.
4.If the protector trips, after the fault is eliminated and before the motor is started, please reset the protector, or else, the motor cannot be started.
5.Motor cooling time: 30min.After the motor overload protection actuated (fault displayed as hEAt), after cooling, it can rest due to heat accumulation.
6.In the actual use on the site, as the protector parameter setting is not rational, the motors may be protected together or are not protected. At this moment, all protection functions will be off. All protection parameters of the protector are set again according to all parameters measured during motor normal operation.
7.If all protection parameters of the protector are appropriate, once the motors actuate together, the protector will work. At this moment, the fault cause is searched according to the actuation code of protector.
8.The protector parameters are defaulted during delivery (except the user’s special requirements). The user may enable all protection functions according to the actual need and set all parameters.
9.If the primary current is 1000A, the external transformer is 1000A/5A. When the protector is connected again, the protector with 5A of current is selected and CT transformation ratio is 200.
Contact Us
- Jiangsu Acrel Electrical Manufacturing CO.,LTD
- Contact nameTim Chat Now
- Phone86-1870-6168051
- AddressJiangyin, Wuxi, Jiangsu
Product Categories
New Products
-
Acrel PZ96-AI3/JC ac three phase led programmable digital ampere meter optional over under curret alarm rs485 modbus
-
Acrel PZ96-AI3/J ac three phase led programmable digital ampere meter with over under current alarm
-
Acrel PZ96-AI3/K ac three phase led programmable digital ampere meter with 4 di/2do
-
Acrel PZ96-E4/KC three phase led programmable digital power meter optional 4DI 2DO
-
Acrel PZ96-E3/MC led programmable digital panel meter optional RS485 4-20mA output over current alarm
-
Acrel PZ72L-AI/MC lCd programmable digital single phase ammter ampere meter optional RS485 analog output
-
Acrel PZ72L-AI/C single phase lcd programmable current meter solar power meter optional RS485 modbus
-
Acrel PZ72-AI3 ac three phase programmable led digital ammeter current meter
-
ACREL PZ96L-E4 3P4W AC Multi-function smart energy analyzer electric meter with LCD display
-
Acrel 300286 PZ96L-E4/KC AC LCD three phase smart power analyzer electric meter with rs485 4 digital input 2 digital output
-
AC PZ96L-E4/KC LCD display three phase energy meter panel meter with rs485 2DI/2DO
-
PZ96L-E4/MC AC LCD three phase power meter panel meter with rs485 4-20mA analog output
-
PZ96L-E4/KC Multi-function remote control meter with switching and communication functions
-
PZ96L-E4/C AC LCD three phase voltage current power kwh meter panel meter with rs485
-
Acrel PZ72-AI/JMC single phase led programmable digital panel meter ampere meter optional RS485 4-20mA output alarm
-
Acrel-5000 power meter Energy Management System
-
Acrel5000 Energy consumption Management System
-
Acrel/3200 Prepaid Power Energy Management System
-
ACREL (Stock Code:300286.SZ) three-phase intelligent digital power meter rs485 75*75 panel mounted
-
AC digital display single-phase LCD ammeter current meter
-
ACREL (Stock Code:300286.SZ) AC Ampere Meter LCD displayed-Single phase PZ48L-AI
-
ACREL (Stock Code:300286.SZ) AC Intelligent three-phase Embedded Power Meter PZ96-E3(E4)
-
ACREL (Stock Code:300286.SZ) intelligent three-phase 75*75 panel mounted lcd power meter
-
AC intelligent digital LCD display single-phase programmable ammeter 48*48/72*72/96*96/80*80 current meter
Popular Searches
- power transformer
- Distribution Service
- current transformer
- power transformers
- High Frequency Transformer
- Electrical Transformer
- energy saver device
- led transformers
- step up converter
- Ac Drive Converter
- Frequency Drive Converter
- lightning conductor
- Copper Lightning Rod
- electronic transformer
- Lighting Transformers
- toroidal transformer
- auto transformer
- current transformer inductor
- voltage transformer
- Control Transformer
- Power Supply Transformer
- Led Lighting Transformer
- Waterproof Transformer
- Electric Transformer
- Low Frequency Transformer
- Flyback Transformer
- Core Transformer
- pot & kettle
- Output Inductor
- Power Distribution Equipment
Recommended Products
- BENTLY NEVADA 330130-045-02-CN
- BENTLY NEVADA 330750-60-05
- BENTLY NEVADA 330930-045-04-CN
- BENTLY NEVADA 330703-00-100-10-11-CN
- BENTLY NEVADA 330400-01-CN
- BENTLY NEVADA 330901-00-18-70-02-CN
- BENTLY NEVADA 330103-00-03-10-01-CN
- BENTLY NEVADA 330130-085-13-CN
- BENTLY NEVADA 330909-00-20-10-02-CN
- BENTLY NEVADA 330902-00-40-10-02-CN
- BENTLY NEVADA 330905-00-09-05-02-CN
- BENTLY NEVADA 330907-05-30-10-02-CN
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Tim
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile