Home > Products > Multifunction Power Meter > three phase network analyzer, Multifunction Energy Meter RS485/Modbus/Profibus communication power quality analyzer
three phase network analyzer, Multifunction Energy Meter RS485/Modbus/Profibus communication power quality analyzer
- Shanghai
- T/T Credit Card
- 10 days
You May Like
-
Acrel 300286 three phase 3 wire/4 wire LCD Digital Display Multifunction Energy Meter With RS485/Modbus/Profibus
-
wireless GPRS 2G leakage current single phase Din rail energy meter ARCM300D-Z-2G
-
ARCM300T-Z-2G wireless GPRS 2G leakage current three phase Din rail energy meter
-
Acrel ARCM300T-Z-NB wireless NB-lot leakage current three phase Din rail energy meter
-
Acrel ARCM300T-Z-4G wireless GPRS 4G leakage current three phase Din rail energy meter
-
Acrel ARCM300D-Z-2G wireless GPRS 2G leakage current three phase Din rail energy meter
Product Details
Brand Name | ACREL | Place of Origin | China | |
Model Number | APM800 | Phase | Three Phase | |
Output Voltage | 220V | Operating Temperature | -20~65 | |
Dimensions | 92*92 | Display Type | Digital Only | |
Accuracy Class | 0.2 | Measuring Energy Range | 0~999999 |
Product Description
General
APM series meters have full power measurement, energy statistics, analysis of power quality and network communications and other functions, are mainly used for comprehensive monitoring of the quality of power supply network.
Parameters
Technical Parameters | Index | |||
Signal | Electrical network | Three-phase three-wire, three-phase four-wire, see the wiring diagram; | ||
Frequency | 45~65Hz; | |||
Voltage | Rated value:AC 100V、110V、400V、690V; | |||
Overload: 1.2 times rated value(continuous); 2 times rated value /1 second; | ||||
Power consumption:<0.5VA (per channel); | ||||
Current | Rated value: AC 1A, 5A, support 4 mm2 line access; | |||
Overload: 1.2 times rated value(continuous); 10 times rated value/1 second; | ||||
Power consumption:<0.5VA (per channel); | ||||
Measurement accuracy | Voltage、current and power | class 0.5s/class 0.2s (APM800、APM810/APM801) | ||
Active power | class 0.5s/class 0.2s (APM800、APM810/APM801) | |||
Reactive power | class 2 | |||
Harmonic | 1%(2rd~42nd)、2%(43rd~63rd) | |||
Switch inputs | Dry contact inputs, built-in power supply; | |||
Relay outputs | Contact type: open contact in main part, changeover contact in module; Contact capacity:AC 250V/3A DC 30V/3A; | |||
Pulse output of energy | Output mode: Optocoupler pulse with open collector; Pulse constant:4000(5A)、8000(1A) imp/kWh; | |||
Analog outputs | DC 0mA~20mA、4mA~20mA、0V~5V、1V~5V output, accuracy class 0.5%, load resistance ≤ 500Ω; | |||
Analog inputs | DC 0mA~20mA、4mA~20mA、0V~5V、1V~5V iutput, accuracy class 0.5% | |||
Storage card | Standard Capacity:4G,TF Card Up to 32G Capacity; | |||
Communication | RS485 interface/Modbus-RTU protocol and DLT645 protocol Profibus-DP interface/Profibus-DP protocol; RJ45 interface (Ethernet) / Modbus-TCP, http, DHCP and other protocols; | |||
Power supply | Working range: AC/DC 85V~265V or AC/DC 115~415V(P2); Power consumption: Power consumption of the main part ≤ 15VA; | |||
Safety | Power frequency withstand voltage | The power frequency withstand voltage between the shell and the auxiliary power supply, each input and output terminal group is AC 4kV/1min; The power frequency withstand voltage between the auxiliary power supply and each input and each output terminal group is AC 2kV/1min; The power frequency withstand voltage between the voltage input and other input/output terminal groups is AC 2kV/1min; The power frequency withstand voltage between the current input and other input/output terminal groups is AC 2kV/1min; The power frequency withstand voltage between the relay output and other input/output terminal groups is AC 2kV/1min; The power frequency withstand voltage between each terminal group of switch input, communication, analog output and pulse output is AC 1kV/1min; | ||
Insulation resistance | Inputs、outputs to the shell>100MΩ; | |||
Electromagnetic compatibility | Meet IEC 61000 standard (Level 4); | |||
Protection level | Display panel IP52 | |||
Environment | Operating temperature: -20 °C ~ +65 °C; Storage temperature: -20°C~+70°C; Relative humidity: ≤95% without condensation; Altitude: ≤2500m; | |||
Standards | IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-30 | Environmental Testing-Part 2-1:Tests Test A:Cold IDA Part 2-1:Tests Test B:Dry heat Part 2-30:Tests Test Db:Damp heat,cyclic(12+12h) | ||
IEC 61000-4 | Electromagnetic compatibility-Testing and measurement techniques | |||
IEC 61557-12 | Electrical safety in low voltage distribution system up to 1000V a.c. and1500V d.c –Equipment for testing,measuring or monitoring of protective measures- Part12: Performances measuring and monitoring devices(PMD) | |||
IEC 62053-22 | Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2s and 0.5s) |
Overseas sales engineer: Tim Ma
email:tim.ma@email.acrel.cn
Mob:+86 18761599716(whatsapp/skype/wechat)
Contact Us
- Jiangsu Acrel Electrical Manufacturing CO.,LTD
- Contact nameTim Chat Now
- Phone86-1870-6168051
- AddressJiangyin, Wuxi, Jiangsu
Product Categories
New Products
-
ACREL AEW100-D36X wireless three-phase power meter with rs485 470MHZ lora communication
-
ACREL AEW100-D36X three phase wireless remote control smart power meter with rs485 470MHZ lora communication
-
ACREL AEW110-L lora wireless communication energy meter with rs485 infrared communication
-
ACREL AEW110-L wireless communication power meter with rs485 infrared communication
-
ACREL 300286 AEW110-L lora wireless power meter with rs485 470Mhz wireless communication
-
ACREL AEW110-L wireless communication convertor with rs485 realize wireless networking
-
ACREL AEW100-D15X wireless power meter with rs485 for low voltage network three phase active energy metering
-
ACREL AEW100-D15X wireless three phase metering counting analyzing power meter with rs485 470MHZ lora communication
-
ACREL AEW100-D15X wireless three-phase active accuracy class 1energy meter with rs485 470MHZ lora communication
-
ACREL AEW100-D15X three phase U I P Q measurement energy meter with rs485 470MHZ wirelesslora communication
-
ACREL 300286 AEW100-D20X wireless three-phase energy meter with rs485 470MHZ lora communication
-
Acrel 300286 AEW-D20X/TN wireless remote control energy meter Lora 470MHZ airwave power meter RS485 modbus KWH meter
-
ACREL (Stock Code:300286.SZ) AEW-D20X smart electrical meters Lora wireless power meter RS485 modbus energy measurement
-
ACREL (Stock Code:300286.SZ) AEW-D20X wireless electricity meter Lora power meter RS485 modbus energy measuring without display
-
Acrel three phase Din mounted energy meters with rs485
-
Acrel three phase Din rail energy meter with rs485 for solar power use
-
Acrel 300286 three phase Din rail energy meter with multi-rate energy computation
-
Acrel three phase Din rail modbus digital energy meter
-
Acrel three phase Din rail RS485-Modbus power monitor
-
Single phase Din rail energy meter, modbus rtu energy meter PV solar system, power monitoring for sub metering use
-
Single phase Din rail energy meter Digital energy meter with Rs485/Modbus-RTU for EV charger
-
Single phase Din rail energy meter Digital energy meter with Rs485/Modbus-TRU PV solar system
-
energy meter expert/ Smart Three phase DIN Rail Energy Meter modbus multi function meter
-
LCD Din MODBUS three phase energy meter kWh meter din rail energy meter watt meter solar power meter
Popular Searches
- voltmeter
- panel meter
- multimeter
- ammeter
- measuring instruments
- electronic instrument
- Phase Multifunction Meter
- Smart Meter
- Power Meter
- Energy Power Meter
- Electricity Meter
- kwh meter
- digital meter
- electric meter
- power monitor
- Electric Energy Meter
- Single Phase Multifunction Meter
- Test System
- energy equipment
- din rail
- Electrical Power Meter
- high accuracy
- watt- hour meter
- power supply
- Oscilloscopes
- otdr
- Optical Power Meter
- signal analyzer
- Digital Signal Generator
- spectrum analyzer
Recommended Products
- Wifi Smart energy Meter
- Smart Energy Meter Single phase LCD Display
- Din rail Energy Meter Single phase
- PIU2000A 0.01% Grade high precision DC Tester
- Industry-Leading Support Acrel DJSF1352-RN/S RS485 Modbus-RTU Communication Din Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate/0.5S accuracy shunt connect
- Innovative Design Acrel DJSF1352-RN/2C RS485 Modbus-RTU Communication Din Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate/second channel RS485
- Reliable Performance Acrel DJSF1352-RN/D Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate/second channel DC measurement RS485 Modbus-RTU Communication
- Precise Monitoring Acrel DJSF1352-RN/K RS485 Modbus-RTU Communication Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate/2DI+2DO
- Acrel DJSF1352-RN Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate RS485 Modbus-RTU Communication
- Acrel ADW300/L 1 channel of residual current measurement Din rail smart electrical meter to monitor, collect and manage electricity
- Acrel ADW300/T 4 channel temperature measurement Din rail smart electrical meter to monitor, collect and manage electricity
- Acrel ADW300/K 4DI+2DO Din rail smart electrical meter to monitor, collect and manage electricity
Find Similar Products By Category
- Instruments & Meters > Meter for Electricity > Energy Meter & Power Meter
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Tim
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile