Home > Products > IT Power Distribution > Acrel 300286 medical IT intelligent insulation monitoring device AIM-M10
Acrel 300286 medical IT intelligent insulation monitoring device AIM-M10
USD $1,243.9 - $1,243.9
/ Piece
1 Piece(Min.Order)
- 1000 Piece / Pieces per Month
- T/T Credit Card
You May Like
-
Acrel 300286 AIM-M10 with CE approval medical IT isolated power supply system insulation monitor
-
Acrel 300286 medical IT system insulation monitor AIM-M10 with CE certificate
-
ACREL 300286 AIL100-8 medical IT insulation fault locator locate the insulation faults
-
ACREL 300286 insulation fault locator for hospital medical IT system AIL100-8
-
ACREL 300286 AIL100-8 medical IT monitoring system insulation fault locator
-
ACREL 300286 AIL100-8 insulation fault locator applied in insulation system
Product Details
Brand Name | Acrel | Place of Origin | Jiangsu, China | |
Model Number | AIM-M10 | Operating Temperature | -10~55℃ | |
Dimensions | 54*85*63.6mm | Display Type | Digital Only | |
Accuracy Class | Class 5 | Measuring Range | 0-99999 | |
Testing Voltage | AC 220V |
Product Description
Product Description
General
Hospital IPS monitor system insulation monitor AIM-M10 with CE approval
medical intelligent insulation monitoring instrument adopts advanced microcontroller technology, which has high integration,
compact size, convenient installation and integrates intelligence, digitalization and networking in one. It is ideal selection for
insulation monitoring of isolation power system in Class 2 medical locations such as operating room and intensive care unit.
medical intelligent insulation monitoring instrument adopts advanced microcontroller technology, which has high integration,
compact size, convenient installation and integrates intelligence, digitalization and networking in one. It is ideal selection for
insulation monitoring of isolation power system in Class 2 medical locations such as operating room and intensive care unit.
Features
* real-time monitoring and fault alarming of the ground insulation resistance,
* transformer load current and transformer winding temperature of the monitored IT system,
* be used with insulation fault locator, remotely starting fault-locating and displaying locating results when there are
insulation faults,
* real-time monitor the line disconnection fault, temperature sensor disconnection fault and the functional grounding line
disconnection fault of the monitored system, and give the alarm indication within 2S after the fault occurs,
* relay alarm output, LED alarm indication and other faults indication functions,
* used for centralized alarm and display instrument, test signal generator, insulation fault locator and upper computer management
software communications, and can monitor the operation status of IT system in real time.
* Events logging function, which can record alarm occurrence time and fault type and is convenient for operation personnel to
analyze the operation conditions of system and promptly eliminate the faults.
* transformer load current and transformer winding temperature of the monitored IT system,
* be used with insulation fault locator, remotely starting fault-locating and displaying locating results when there are
insulation faults,
* real-time monitor the line disconnection fault, temperature sensor disconnection fault and the functional grounding line
disconnection fault of the monitored system, and give the alarm indication within 2S after the fault occurs,
* relay alarm output, LED alarm indication and other faults indication functions,
* used for centralized alarm and display instrument, test signal generator, insulation fault locator and upper computer management
software communications, and can monitor the operation status of IT system in real time.
* Events logging function, which can record alarm occurrence time and fault type and is convenient for operation personnel to
analyze the operation conditions of system and promptly eliminate the faults.
Dimension
Wiring
Typical connnection
Techinical Parameter
Model | AIM-M10 |
Voltage | AC220V( fluctuation range ±10%) |
Frequency | 50/60Hz |
Max power consumption | <8VA |
Insulation resistance measuring range | 50~999kΩ |
Relative percentage accuracy | 0~±10% |
Alarm value range | 10~999kΩ |
Response time | <2S |
Measuring voltage | <12V |
Measuring current | <42μA |
Measuring range | 2.1~50A |
Alarm value range | 5~50A |
Measuring accuracy | class 5 |
Display | Digital and percentage display |
thermal resistor | PT100 |
Measuring range | -50℃~+200℃' |
Alarm value range | 0℃~+200℃' |
Output type | 1 channel relay output(unable to program) |
Contact rating | AC 250V/3A DC30V/3A |
Working temperature | -10℃~+55℃' |
Storage temperature | -20℃+70℃' |
Relative humidity | 5%~95%,non-condensing |
Altitude | ≤2500m |
Communication | one channel RS485,MODBUS-RTU |
Rated impulse voltage/pollution class | 4KV/III |
EMC and electromagnetic radiation | In accordance with IEC1326-2-4 |
Certificate
Contact Us
- Jiangsu Acrel Electrical Manufacturing CO.,LTD
- Contact nameTim Chat Now
- Phone86-1870-6168051
- AddressJiangyin, Wuxi, Jiangsu
Product Categories
New Products
-
ACREL 300286 AIL100-8 medical IT insulation fault locator locate the insulation faults
-
ACREL 300286 insulation fault locator for hospital medical IT system AIL100-8
-
ACREL 300286 AIL100-8 medical IT monitoring system insulation fault locator
-
ACREL 300286 AIL100-8 insulation fault locator applied in insulation system
-
ACREL 300286 AIL100-8 insulation fault locator used in medical IT system
-
ACREL 300286 AIL100-8 medical IT insulation fault locator locate the insulation faults
-
ACREL 300286 insulation fault locator for hospital medical IT system AIL100-8
-
ACREL 300286 AIL100-8 medical IT monitoring system insulation fault locator
-
ACREL 300286 AIL100-8 insulation fault locator applied in insulation system
-
ACREL 300286 AIL100-8 insulation fault locator used in medical IT system
-
Acrel 300286 AIM-M100 hospital IT isolated power supply moniroting system insulation monitor
-
Acrel 300286 AIM-M100 healthcare IT operating theater isolation power systems / IPS for electrical safety insulation monitor
-
Acrel 300286 medical IPS monitoring system insulation monitor AIM-M100
-
Acrel 300286 medical IT system insulation monitoring device AIM-M100
-
Acrel 300286 AIM-M200 Medical IT system used Intelligent Insulation monitoring relay
-
Acrel 300286 AIM-M200 hospital IPS isolated power supply monitoring system insulation monitor
-
Acrel 300286 AIM-M200 medical IT systems AC current multifunctional insulation relay
-
Acrel 300286 AIM-M200 insulation monitoring relay for hospital IPS monitoring system
-
Acrel IP31 IT system electric power distribution isolation cabinet GGF-I6.3G used in CCU
-
Acrel Hospital isolated power supply 7 pieces sets
-
ACREL 300286 AIL100-8 insulation fault locator used in medical IT system
-
ACREL (Stock Code:300286.SZ) Hospital IT medical insulation monitoring devices monitor the insulation resistance of IT systems
-
ACREL (Stock Code:300286.SZ)insulation monitoring device for medical IT insulated isolation power system AIM-M200
-
Isolated Power Monitor System for Hospital alarm indicator
Popular Searches
Recommended Products
- Acrel AIM-M200 Medical Intelligent Insulation Monitoring Device For IT System ICU CCU With Alarm Output Hospital Isolation
- Acrel AIM-M200 Medical Intelligent Insulation Monitoring Device For IT System ICU CCU With Alarm Output Hospital Isolation
- Insulation Monitoring Device Acrel AIM-M200 Hospital Insulation Monitoring Device Accurate Insulation Resistance Monitoring
- Acrel AIM-M200 Hospital Insulation Monitoring Device Accurate Insulation Resistance Monitoring
- Acrel AIM-M200 Insulation Monitoring Device For IT System/Electric Insulation Monitoring Device
- hospital isolation transformer system insulation monitoring device
- medical IT system hospital isolation transformer system insulation monitoring device insulation fault locator
- acrel AIM-M200 medical IT system hospital isolation transformer system insulation monitoring device insulation fault locator
- insulation monitoring device for IT systems
- Digital display DC Low Resistance Tester Low value resistance tester
- Digital earth resistance tester ground resistance meter soil resistivity test
- Double clamp grounding resistance tester soil resistivity ground voltage DC voltage and AC current
Find Similar Products By Category
- Instruments & Meters > Meter for Electricity > Resistance Meter
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now
Jiangsu Acrel Electrical Manufacturing CO.,LTD
AIBot OnlineThis conversation is AI-generated. Contact manufacturer before transaction to confirm info.
-
Tim
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile