Home > Products > Life science instruments and equipments > RM-6240BD multi-channel physiological signal acquisition and processing system
RM-6240BD multi-channel physiological signal acquisition and processing system
- 30 Set / Sets per Month
- SHENZHEN
- T/T Credit Card
You May Like
-
PHJ-1 multi-function constant temperature smooth muscle experiment tank
-
RM-6240E physiological signal acquisition and processing system
-
MD-2300S ophthalmic A/B ultrasonic diagnostic apparatus
-
HM300 knife mill grinding machine
-
HM100 knife mill grinding machine
-
FM200 ultracentrifugal mill grinding machine
Product Details
Brand Name | CY | Place of Origin | Shaanxi, China | |
Model Number | RM-6240BD | Type | Biochemical Analysis System |
Product Description
Introduction:
The system uses a true external structure. It is suitable for laptops as well as desktop computers. Interface with computer: USB2.0. Since the internal A/D acquisition part of the system uses a separate circuit board (in an external chassis), no matter how the interface technology of the computer develops, the instrument can adapt to the development of the computer by replacing the A/D collector module and the corresponding software. Instrument upgrade is very convenient. The stimulator uses an optically coupled full isolation system and the ECG has 12 lead modes with international standards.
Technical Parameters:
1. The instrument adopts integrated anti-interference power supply, and the power supply exchanges 220V. Except for the built-in transformer of the chassis, there is no need to connect any transformers outside, thus ensuring that the bioelectricity of the instrument can be ensured without any external ground wire when performing any bioelectricity experiment. The signal is clear and accurate. Thereby ensuring the anti-interference performance and accuracy of the machine.
2. The instrument has 4 channels (eight channels for 8 channels), all of which are multi-function full-controlled isolated amplifiers. The amplifier of each channel can be used as a bioelectric amplifier, a blood pressure amplifier, a bridge amplifier, and can also be used as a spirometer, a thermometer, and the like. Each channel has independent hardware modules, which are independent of each other, greatly increasing the anti-interference ability between the channels, and also bringing great convenience to the maintenance and repair of the instrument.
3. Using high-precision 16-bit A/D conversion chip, the maximum sampling rate of single-channel hardware is 1000KHz. The minimum hardware sampling rate is 0.01Hz. The maximum sampling frequency is 200 kHz for four-channel continuous sampling, and the sampling rate can be changed as needed during real-time sampling.
4. Scanning speed: 0.05ms/div~3200s/div.
5. Amplifier input resistance ≥100MΩ (double-ended input) and 50MΩ (single-ended input), common mode rejection ratio ≥100dB, noise ≤±1μV (RMS) or ≤±3μV (P-P).
6. Frequency response: DC~20kHz.
8. Sensitivity:
a) Bioelectric mode: 20uV/div~500mV/div
b) Blood pressure mode 3.6-360 (mmHg/div) 0.36-180 (mmHg/div) (high sensitivity transducer)
9. AC and DC have the same gain: range 500mv, 200mv, 100mv, 50mv, 20mv, 10mv, 5mv, 2mv, 1mv, 500uV, 200uV, 100uV, 50uV, 20uV, 10uV adjustable; can directly input 10V electrical signal The amplifier is not saturated.
10. Low-pass filtering (hardware): 0.3 Hz, 3 Hz, 10 Hz, 30 Hz, 100 Hz, 500 Hz, 1 kHz, 3 kHz, 10 kHz, OFF (20 kHz). It has a filtering method of 5 or more steps.
11. Time constant (hardware): 0.001 s, 0.002 s, 0.02 s, 0.2 s, 1 s, 5 s, DC.
12. Main technical requirements of photoelectric isolation program-controlled stimulator: single stimulus, string single stimulation, continuous single stimulation, double stimulation, string double stimulation, continuous double stimulation, timing stimulation, intensity increasing stimulation, frequency increasing stimulation, increasing wave width stimulation Stimulation patterns such as strong interval increment stimulation and automatic string double stimulation. Maximum load current: 100 mA, with positive current, negative current output mode, to meet the national standards for safe use of electricity, and will not cause electric shock due to misuse. The output voltage is <=50V to meet the national safe electricity standard. 13. Digital filtering mode: 1) High-pass, low-pass, band-pass, and band-stop with adjustable filter parameters. 2) Zero-phase shift digital filtering with adjustable order. 14. The hardware system includes ECG full-lead lead-in card, each channel can be used for 12 kinds of lead-type ECG, lead switching mode can be programmed, and there are 12 lead modes: I, II, III, aVR, aVL , aVF, V1, V2, V3, V4, V5, V6. |
Dear customer,
We ,Xi’an Yima Opto-electrical Technology Com.,Ltd. is an integrated economic entity of R&D,manufacturing and trading with over 20 years of history .
Our business scope covers various fields such as biochemical analysis,environmental protection,industrial testing, bioscience,medical apparatus and instruments,internet technology and some frontier science.
Through a long-time development,we own a national resources system of various professional talents , abundant supply for various components &parts and special materials, full producing &processing equipments , strong Technological standardization and a complete quality assurance system.
If you need OEM or ODM in manufacturing ,scientific research , market development and or you want to build your own brand in your country, it’s our honor to cooperate with you.In this way ,we have developed many products for our customers from the USA, Europe and South Africa and got good feedback on Alibaba
We firmly believe that science and technology is no boundaries
Our mission is to make every effort to contribute to all humanity.
Contact Us
- Lixian Instrument Scientific Co., Ltd.
Product Categories
New Products
-
CM100M compound grinding machine
-
CM200 cutting pulverizer grinding machine
-
VM3 Vibrating Cup Mill grinding machine
-
KHE-5 electrolyte Analyzer
-
KH-996 Electrolyte Analyzer
-
KHB202 Coagulometer(New)
-
KN-4003AL2/BL2 (D) UV Phototherapy
-
KN-4004 UV Phototherapy
-
KN-4001 UV Pholotherapy
-
D320 automatic biochemical analyzer
-
AT-150 exhaled gas condensate collector EBC collection
-
SVQD-100C Full automatic headlamp tester
Popular Searches
- oxygen tester
- sulfur analysis
- oxygen sensor testing
- Concentration Meters
- concentration sensor
- Alkali Concentration Meter
- nitrogen tester
- tds monitor
- tds meter
- water instruments
- conductivity meter
- ph probe
- ph analyzer
- ph monitor
- Oxygen Meter
- Ion Meter
- Water Quality Meter
- thermometer probe
- digital thermometer probe
- concentration meter
- viscosity tester
- Tuning Meter
- platinum tester
- Water Quality Tester
- computer assisted semen analysis
- water analysis instruments
- Digital Turbidimeter
- water analysis equipment
- digital multi tester
- hour counter
Recommended Products
- Medical Dry Biochemical Analyzer
- NJbinglab PTFE Filter Clip Filtration and Separation of Substances
- NJbinglab PTFE 166mm wafer cassette with acid tank for Wet Etch
- NJbinglab Teflon Hydrogen Fluoride Distillation Condensation Device
- PFA 7ml 15ml Vials Screw Cap with Various Bottoms
- PFA 6000ml Vials Cleaning System with Rack for Isotope Analysis
- ELISA Microplate Reader Emisean
- Pathology Equipment Touch Screen Slide Warmer Laboratory Tissue Slide Dryer
- Pathology Equipment Touch Screen Tissue Flotation Bath Tissue Water Bath
- Oral thermometer, axillary thermometer, mercury thermometer
- Mercury in glass thermometer
- Aps Nesswell Medical Tissue Fully Automated Microtome
Find Similar Products By Category
- Health & Medicine > IVD
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile