Brand Name | ZYDQ | Place of Origin | China |
Product Description
S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer
The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.
Product Description
The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.
S11 series transformer adopts high quality material for copper winding, especially applying the new technology and new material for the coil insulation and active parts, thus the no-load and the load loss are obviously reduced, the performance and structure are more reliable and superior.
Product Features
● Good Economic Performance
The no-load loss for S11 series products decreased 10.3% averagely, no-load current decreased 22.4% based on S9 series.
● Long Service Life
Transformer tank adopts hermetical structure, tank and tank cover can be connected by bolts or welded firmly, the transformer oil won’t contact with air, so that extend the service life effectively.
● High Operation Reliability
Improve the relevant sealing parts for the tank, increase the reliability and advance the technical level to ensure the reliability of the seal.
● Small Installation Area
S11-M series transformer tank uses the corrugated plate radiator. When the oil temperature changes, the corrugated plate will proceed thermal expansion, which can replace the role of the oil conservator. the corrugated plate tank has beautiful appearance, less occupied area.
Model and Meaning
Table 1: 6Kv, 10kV & 30kVA-2500kVA Power Transformer With Off Circuit Tap Changer
Rated Capacity (kVA) | Voltage Combination | Connection Group Symbol | No-load Loss R(W) | Load Loss R(W)75℃ | Impedance Voltage (%) | No-load Current(%) | Length L(mm) | Width W (mm) | Height H(mm) | Gauge Horizontal*Vertical(mm) | Active parts Weight(Kg) | Oil Weight(Kg) | Total Weight(Kg) | ||
(KV) High Voltage | Tapping Range of High Voltage | (KV)Low Voltage | |||||||||||||
30 | 66.31010.5 | ±5%±2×2.5% | 0.4 | Dyn11Yzn11Yyn0 | 100 | 630/600 | 4.0 | 2.8 | 980 | 735 | 1145 | 400*400 | 178 | 78 | 355 |
50 | 130 | 910/870 | 2.5 | 1017 | 758 | 1205 | 450*400 | 240 | 92 | 415 | |||||
63 | 150 | 1090/1040 | 2.4 | 1035 | 785 | 1285 | 450*400 | 285 | 105 | 505 | |||||
80 | 180 | 1310/1250 | 2.2 | 1065 | 800 | 1290 | 450*400 | 330 | 110 | 540 | |||||
100 | 200 | 1580/1500 | 2.1 | 1072 | 820 | 1305 | 450*400 | 345 | 116 | 590 | |||||
125 | 240 | 1890/1800 | 2.0 | 1155 | 1105 | 1310 | 450*550 | 415 | 135 | 705 | |||||
160 | 280 | 2310/2200 | 1.9 | 1235 | 850 | 1535 | 550*550 | 485 | 155 | 835 | |||||
200 | 340 | 2730/2600 | 1.8 | 1282 | 860 | 1557 | 550*550 | 582 | 168 | 965 | |||||
250 | 400 | 3200/3050 | 1.7 | 1310 | 940 | 1605 | 550*550 | 695 | 210 | 1135 | |||||
315 | 480 | 3830/3650 | 1.6 | 1465 | 1120 | 1915 | 660*650 | 855 | 255 | 1520 | |||||
400 | 570 | 4520/4300 | 1.5 | 1440 | 1165 | 1725 | 660*660 | 950 | 295 | 1590 | |||||
500 | 680 | 5410/5150 | 1.4 | 1510 | 1250 | 1845 | 660*650 | 1150 | 320 | 1905 | |||||
630 | 810 | 6200 | 1.3 | 1650 | 1140 | 1920 | 660*650 | 1500 | 435 | 2015 | |||||
800 | 980 | 7500 | 4.5 | 1.2 | 2125 | 1175 | 2315 | 820*820 | 1910 | 760 | 3510 | ||||
1000 | 1150 | 10300 | 1.1 | 2150 | 1380 | 2570 | 820*820 | 2125 | 880 | 3850 | |||||
1250 | 1360 | 12000 | 1.0 | 2355 | 1485 | 2570 | 820*820 | 2605 | 960 | 4610 | |||||
1600 | 1640 | 14500 | 0.9 | 2385 | 1750 | 2630 | 820*820 | 3125 | 1150 | 5420 | |||||
2000 | 1940 | 18300 | 5.0 | 0.4 | 1940 | 1400 | 1700 | 820*820 | 2420 | 780 | 4200 | ||||
2500 | 2290 | 21200 | 0.4 | 2050 | 1480 | 1800 | 820*820 | 2560 | 880 | 4680 |
Notes:
1. The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
2. For the transformer of rated capacity up to 500kVA, the value of load loss above the oblique line in the table is applicable to the connection group Dyn11 or Yzn11. The value of load loss under the oblique line is applicable to the connection group Yyn0.
Technical Parameter for S11 Series 20kV Power Transformer With Off Circuit Tap Changer
Rated capacity(KVA) | Voltage Combination | Connection Group Symbol | No-load Loss(W) | Load Loss (W)75℃ | No-load Current (%) | Short-circuit Impedance(%) | ||
High Voltage (KV) | Tapping ranges of High Voltage | Low Voltage(KV) | ||||||
30 | 20 | ±5% ±2×2.5% | 0.4 | Dyn11Yzn11Yyn0 | 100 | 690/660 | 2.1 | 5.5 |
50 | 130 | 1010/960 | 2.0 | |||||
63 | 150 | 1200/1150 | 1.9 | |||||
80 | 180 | 1440/1370 | 1.8 | |||||
100 | 200 | 1730/1650 | 1.6 | |||||
125 | 240 | 2080/1980 | 1.5 | |||||
160 | 290 | 2540/2420 | 1.4 | |||||
200 | 340 | 3000/2860 | 1.3 | |||||
250 | 400 | 3520/3350 | 1.2 | |||||
315 | 480 | 4210/4010 | 1.1 | |||||
400 | 570 | 4970/4730 | 1.0 | |||||
500 | 680 | 5940/5660 | 1.0 | |||||
630 | 810 | 6820 | 0.9 | 6.0 | ||||
800 | 980 | 8250 | 0.8 | |||||
1000 | 1150 | 11330 | 0.7 | |||||
1250 | 1380 | 13200 | 0.7 | |||||
1600 | 1660 | 15950 | 0.6 | |||||
2000 | 1950 | 19140 | 0.6 | |||||
2500 | 2340 | 22220 | 0.5 |
Notes:
1. The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
2. For the transformer of rated capacity up to 500kVA, the value of load loss above the oblique line in the table is applicable to the connection group Dyn11 or Yzn11. The value of load loss under the oblique line is applicable to the connection group Yyn0.
3. The performance parameters in the table are also applicable for HV with dual voltage 20 (10)kV three-phase transformer.
Technical Parameter for S11 Series 35kV Power Transformer With Off Circuit Tap Changer
Model | Voltage Combination | Connection Group Symbol | No-load Loss (W)75℃ | Load Loss R(W) | Impedance Voltage (%) | No-load Current(%) | Length L(mm) | Width W(mm) | Height H(mm) | Gauge Horizontal*Vertical (mm) | Active parts Weight(Kg) | Oil Weight(Kg) | Total Weight(Kg) | ||
High Voltage (kV) | Tapping Range of High Voltage % | Low Voltage (kV) | |||||||||||||
50 | 3538.5 | ±2×2.5%±5% | 0.4 | Dyn11/ Yyn0 | 160 | 1200/1140 | 6.5 | 1.3 | 1195 | 935 | 1825 | 660*660 | 300 | 330 | 860 |
100 | 230 | 2010/1910 | 1.1 | 1200 | 995 | 1935 | 660*660 | 470 | 383 | 1130 | |||||
125 | 270 | 2370/2260 | 1.1 | 1235 | 940 | 1955 | 660*660 | 550 | 465 | 1335 | |||||
160 | 280 | 2820/2680 | 1.0 | 1285 | 895 | 1950 | 660*660 | 580 | 485 | 1475 | |||||
200 | 340 | 3320/3160 | 1.0 | 1310 | 1150 | 1985 | 660*660 | 680 | 595 | 1755 | |||||
250 | 400 | 3950/3760 | 0.95 | 1450 | 1090 | 2010 | 660*660 | 860 | 650 | 2000 | |||||
315 | 480 | 4750/4530 | 0.95 | 1930 | 1065 | 2320 | 820*820 | 980 | 765 | 2290 | |||||
400 | 580 | 5740/5470 | 0.85 | 1850 | 1165 | 2015 | 820*820 | 1170 | 885 | 2725 | |||||
500 | 680 | 6910/6580 | 0.85 | 2045 | 1205 | 2415 | 820*820 | 1340 | 960 | 3090 | |||||
630 | 830 | 7860 | 0.65 | 2085 | 1240 | 2515 | 660*660 | 1550 | 895 | 3810 | |||||
800 | 980 | 9400 | 0.65 | 2305 | 1615 | 2685 | 820*820 | 1990 | 1030 | 4510 | |||||
1000 | 1150 | 11500 | 0.65 | 2545 | 1540 | 2590 | 1070*1070 | 2415 | 1475 | 5055 | |||||
1250 | 1400 | 13900 | 0.60 | 2495 | 2010 | 2675 | 820*820 | 2480 | 1405 | 5290 | |||||
1600 | 1690 | 16600 | 0.60 | 2680 | 2100 | 2770 | 820*820 | 2600 | 1490 | 5450 | |||||
2000 | 1990 | 19700 | 0.55 | 2790 | 2180 | 2860 | 820*820 | 2720 | 1590 | 5600 | |||||
2500 | 2360 | 23200 | 0.55 | 2900 | 2290 | 2980 | 1070*1070 | 2830 | 1720 | 5760 |
Notes:
1. The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
2. For the transformer of rated capacity up to 500KVA, the value of load loss above the oblique line in the table is applicable to the connection group Dyn11. The value of load loss under the oblique line is applicable to the connection group Yyn0.
Note: 1.For the transformer of low voltage 10.5kV, the connection group symbol is applicable to Dyn11.
Note: 2.For the transformer of rated capacity 3150kVA or above, the -5% tapping position is for maximum current tap.
Note: 3.When the annual average load rate for the transformer is between 35% to 45%, the loss value in the table can obtain the highest operational efficiency.
We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
Contact Us
- Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd.
- Contact nameJia Qiong Chat Now
- Phone86-312-5926018
- AddressLianchi, Baoding, Hebei
Product Categories
Oil Immersed Transformer | Dry Type Transformer | ZBW Type Prefabricated Substation | ?High and Low Voltage Switchgears |
news |
New Products
-
How to Dry the Transformer?
-
Do You Know What Is The Short Circuit Impedance of The Transformer?
-
Transformer Energy Saving is More and More Popularized
-
Cooling Method of Oil Immersed Power Transformer
-
What is the Line Voltage and Phase Voltage of the Transformer?
-
How To Sample Transformer Oil?
-
What Is Unexcited Voltage Regulation Of Transformer?
-
Transformer Fault Reasons And Preventive Measures
-
How To Prevent The Failure Of Transformer Operation?
-
How To Prevent The Failure Of Transformer Operation?
-
Transformer energy-saving more and more popularize
-
Working principle of transformer
-
How to see the oil position of oil-immersed transformer?
-
Why are transformers mostly used in parallel?
-
What's the transformer for?
-
[Dry transformer for sale China]Assembly of dry type transformers
-
The oil-immersed transformer is set at a distance from the periphery
-
[Transformers for sale]How can oil-immersed transformers reduce copper loss?
-
Why are some pebbles placed around the transformer?
-
How much damage does the electromagnetic radiation of the power transformer have on the body?
-
What is the unexcited voltage regulation of transformer?
-
What is the Line Voltage and Phase Voltage of the Transformer?
-
ZBW Type Prefabricated Substation,mobile transformer substation
-
oil immersed power transformer
Popular Searches
- ignition coil
- power module
- toroidal transformer
- Power Supply Transformer
- Distribution Transformer
- testing transformer
- High Voltage Converter
- High Voltage Generator Transformer
- toroidal coil
- power supply
- led driver
- power inverter
- power transformer
- fuse
- distribution board
- circuit breaker
- current transformer
- Electrical Transformer
- ct
- electronic transformer
- toroidal transformer
- power transmission
- voltage transformer
- Power Supply Transformer
- Electric Transformer
- Electric Switch
- Power Distribution Transformer
- Oil Immersed Transformer
- switchboard
- High Voltage Transformer
Recommended Products
- Emerson 1X01047H01L
- Prosoft MVI56-MNETC
- Bently Nevada 330525-10
- Bently Nevada 330500-07-00
- Bently Nevada 330878-91-00
- Bently Nevada 330101-00-10-10-02-00
- Bently Nevada 330908-00-16-10-01-05
- Bently Nevada 330103-00-05-50-02-00
- Bently Nevada 330104-00-10-50-02-00
- Honeywell FC-TSGASH-1624
- GE IS220PDOAH1BC
- ABB 07DI92?GJR5252400R0101
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Jia Qiong
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile