DW45 Air Circuit Breaker, ACB (hereinafter referred to as circuit breaker) is suitable for distribution network with AC 50Hz, rated voltage to 660V (690V) and below, the rated current 630A~6300A, used to distribute power and protect line and power equipment from overload, undervoltage, short circuit, single-phase grounding and other faults. Air Circuit Breaker have intelligent protection function, selective protection is precise, can improve power supply reliability and avoid unnecessary power outages. At the same time, it has an open communication interface to carry out "Four Remotes" to meet the requirements of the control center and automation system. The circuit breaker has an impulse withstand voltage of 8000V at 2000 meters (revised at different altitudes, not exceeding 12000V). The acb air circuit breaker are not equipped with intelligent controller and sensor, and can be used as isolator.
TAIXI is a professional air circuit breaker manufacturers The acb air circuit breaker meets the GB14048.2 "Low-voltage switchgear and controlgear Low-voltage circuit breakers" and IEC60947-2 "Low-voltage switchgear and controlgear circuit breakers" and other standards.
Home > Products > circuit breaker > DW45 Air Circuit Breaker
DW45 Air Circuit Breaker
- NINGBO
- 30 days
You May Like
Product Details
Brand Name | TAIXI | Place of Origin | China | |
Model Number | DW45 | Poles Number | Other, 3P/4P |
Product Description
● Classification
According to the installation method: fixed type, drawer type.According to the poles: three poles, four poles. According to the operating mode: electric operation, manual operation (overhaul, maintenance).
● Release type
Intelligent controller, under-voltage transient (or delay) release, shunt release.● Intelligent controller performance
a. The intelligent controller of Air Circuit Breaker is divided into: bse5 (H type: communication), bse4 (M type: common intelligent type), bse3 (L type: economic type);b. With overload long delay inverse time limit, short delay inverse time limit, definite time limit, instantaneous function. Users can set their own required protection characteristics;
c. Single-phase grounding protection function;
d. Display function: setting current display, operating current display, main display of each phase voltage (voltage display should be put forward when ordering);
e. Alarm function: overload alarm;
f. Self-check function: overheating self-check, microcomputer self-diagnosis;
g. Test function: Test the operating characteristics of the controller.
● Ambient air temperature: The upper limit value does not exceed +40°C, the lower limit value is not less than -5°C, and the average value in 24h does not exceed +35°C. Note: The working condition is that lower limit value is -10°C or -25°C, the user should declare with the company; The upper limit exceeds +40°C or the lower limit is lower than -10°C or -25°C working conditions, users should consult with the company.
● The altitude of the installation site does not exceed 2000m.
● Atmospheric conditions of Air Circuit Breaker: Atmospheric relative humidity does not exceed 50% when the ambient air is +40°C. It can have relatively high relative humidity at lower temperatures. The monthly average maximum relative humidity of the wetest month is 90%. The average minimum temperature is +25°C and consider the condensation that occurs on the product surface due to temperature changes. Exceed the required requirements and consult with the company.
● Protection level: IP30
● Pollution level: III
● Use category: Class B or Class A
● Installation category: acb air circuit breaker and undervoltage release with rated operating voltage of 660V (690V) or less. The primary coil of the power transformer is used for installation category IV. The installation category of the auxiliary circuit and control circuit is III.
● Installation conditions: The circuit breaker shall be installed in accordance with the requirements of this manual. The vertical inclination of the circuit breaker shall not exceed 5° (the inclination of the mine circuit breaker shall not exceed 15°).
● The positive indication of the circuit breaker
● Rated current of circuit breaker
● Rated short-circuit breaking capacity and short-time withstand current, the circuit breaker's arc distance is zero (that is, no arcing outside the circuit breaker).
Note: The breaking capacity of the upper and lower lines in the table is the same● Protection characteristics and functions of intelligent overcurrent controller
Protection characteristics of overcurrent controller1. The setting value Ir (I/In) and error of the controller
Note: When there is (required) three-stage protection at the same time, the setting values cannot be crossed.
2. Long-delay overcurrent protection inverse-time operation characteristics I2TL=(1.5lr1)2tL, and the operation time of (1.05~2.0)lr1 is shown in Table 4, and the time error is ±15%.
Note: tL-Long delay 1.5lrs setting time, TL-Long delay operation time.
Note: When there is (required) three-stage protection at the same time, the setting values cannot be crossed.
3. Short delay over-current protection characteristics
Short-time delay over-current protection is definite time limit. If the low multiple is required to be inverse time, the characteristic is: I2Ts=(8Ir1)2ts, ts is the general delay design time;
When the overload current >8Ir, it automatically converts to the definite time characteristic. Its definite time limit characteristic is shown in Table 5. The time limit error is ±15°C.
Delay time s | Returnable time s | ||||||
0.1 | 0.2 | 0.3 | 0.4 | 0.06 | 0.14 | 0.23 | 0.35 |
1. Wiring diagram of L, M type intelligent controller (standard type) (see Figure 1)
SB1 - Shunt button (user-supplied)
SB2 - Undervoltage button (user-supplied)
F - Shunt release
O - Normally Open Contact (3A/AC380V)
C - Normally closed contact (3A/AC380V)
Q - Undervoltage instantaneous release or undervoltage delay release
M - Energy storage motor
SB3 - Closing button (user-supplied)
X - Closing electromagnet
DF - Circuit breaker auxiliary contact
1# Work power input end (DC module for positive input)
2# Work power input end (DC module for negative input)
25#, 26# External center pole or ground current transformer input
19#, 20#, 21#, 22#, 23#, 24# are Frame II and III adding contacts.
3# Fault trip, normally closed contact output
4# Fault trip, contact output common end
5# Fault trip, normally open contact output
* When the power supply for the intelligent release is DC power supply, the power supply module must be added. (1# and 2# terminals are prohibited from accessing the AC power supply).
2. Wiring diagram of M, H intelligent controller + additional function (multi function) (see Figure 2)
● Outline and installation dimension of DW45-2000(FrameⅠ) Fixed Air Circuit Breaker
● Outline and installation dimension of DW45-3200 (FrameⅡ) Fixed Circuit Breaker
● Outline and installation dimension of DW45-2000(FrameⅠ) Drawer ACR Air Circuit Breaker
● Outline and installation dimension of DW45-3200(Frame Ⅱ) Drawer Air Circuit Breaker
● Outline and installation dimension of DW45-4000(Frame Ⅱ Increase capacity) Drawer ACR Air Circuit Breaker
● Outline and installation dimension of DW45-4000/4(FrameⅠ3+4 type) Drawer ACR Air Circuit Breaker
● Outline and installation dimension of DW45-6300/4000A~5000A (Frame Ⅲ) Drawer ACR Air Circuit Breaker
● Outline and installation dimension of DW45-6300/3 6300A (Frame Ⅲ) Drawer ACR Air Circuit Breaker
● External connection copper specifications, quantity
/p2/DW45-ACB-air-circuit-breaker-manufacturers
Contact Us
- TAIXI ELECTRIC CO.,LTD.
- Contact namebeckon Chat Now
- Phone86-0577-62711310
- Addressyueqing liushi town, Wenzhou, Zhejiang
Product Categories
circuit breaker |
Popular Searches
- power supply
- fuse holder
- contactor
- micro switch
- electrical switch
- mcb
- rccb
- elcb
- fuse
- switchgear
- distribution board
- rotary switch
- miniature circuit breaker
- vacuum circuit breaker
- mini circuit breaker
- moulded case circuit breaker
- residual current circuit breaker
- air circuit breaker
- earth leakage circuit breaker
- molded case circuit breaker
- mcb circuit breaker
- dc circuit breaker
- mcb mini circuit breaker
- mccb circuit breaker
- ac contactor
- electrical switch
- mcb
- rccb
- elcb
- switchgear
Recommended Products
- THERMODISC Temperature Control 36TMHE01 and Overheat Protector 36FMHE06 for Coffee Machines
- SIEMENS Molded Case Circuit Breaker LSP160T-RU2-BN
- Cheap NL7-63 Series DC Miniature Circuit Breaker 4P NSPV Brand 63A 1500V
- High Quality MCB Miniacture Circuit Breaker Solar DC 2P 1500V Protective Device
- High Quality MCB Miniacture Circuit Breaker Solar DC 2P 1500V Protective Device
- 36FME04 Thermal Trip,G4A50072C,E6A50072C Thermal Fuse for Instant Heating Module Overheat Protector for Smart Toilets
- 17FB179 CARD GE MT4400AC MT3600 KOMATSU 8830E 930E TEREX BELAZ 75131 MINING DUMP TRUCK HAULER
- 17FB174 CARD GE MT4400AC MT3600 KOMATSU 8830E 930E TEREX BELAZ 75131 MINING DUMP TRUCK HAULER
- 2004818 CARD GE MT4400AC MT3600 KOMATSU 8830E 930E TEREX BELAZ 75131 MINING DUMP TRUCK HAULER
- 17FB160 CARD GE MT4400AC MT3600 KOMATSU 8830E 930E TEREX BELAZ 75131 MINING DUMP TRUCK HAULER
- 2004664 BATTERY GE MT4400AC MT3600 KOMATSU 8830E 930E TEREX BELAZ 75131 MINING DUMP TRUCK HAULER
- 2003449 SENSOR GE MT4400AC MT3600 KOMATSU 8830E 930E TEREX BELAZ 75131 MINING DUMP TRUCK HAULER
Find Similar Products By Category
- Electrical & Electronics > Breaker & Protector > Circuit Breaker

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
beckon
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile