Home > Products > Line Post Insulator > Composite Line post Insulator , 252kV / 220kV Station Post Insulators
Composite Line post Insulator , 252kV / 220kV Station Post Insulators
- T/T L/C D/P D/A
- 7 days
You May Like
-
110 kV Polymer Line Post Type Insulator Safety For Power Substations
-
66kV Polymer Station Post Insulators Flameproof High Pollution Resistance
-
35kV Line Post Insulator Minimum Creepage Distance 1320mm For Substations
-
Composite Line Post Insulator , IEC 61952 20kV Substation Insulator
-
ANSI 10 kV / 11 kV Post Insulator Creepage Distance 380mm For Substation
-
Transmission Power Line Polymer Post Insulator 220kV IEC61952 Standard
Product Details
Brand Name | Changgong | Place of Origin | China | |
Model Number | FXZZ-252kV/4kN-9kN |
Product Description
Certification:ISO ; KEMA STRI SGS
?
Composite Line post Insulator , 252kV / 220kV Station Post Insulators
?
?
Specifications:
Dimensions and Characteristics of 220kV(252kV)Line Post Insulator for Substation
?
Figure. No | Model | Rated Voltage | Specified Cantilever Load | Specified Cantilever Load | Section Length | Insulating length | Minimum Creepage | Full-Wave Impulse Withstand Voltage (Peak) | 1 Min Wet Power Frequency Withstand Voltage | Weight (for Reference) |
? | ? | kV | kV | kN | H mm | h mm | L mm | ≥ kV | ≥ kV | kg |
5.1 | FXZZ-252/4 | 220 | 252 | 4 | 2300±3.5 | 2050 | 6300 | 1050 | 460 | 66.3 |
Description:
?
1, 220kV(252kV)Line Post Insulator are widely used in power transmission lines and substations
?
2, Dead end fittings are up to the requirements from the clients,the dimensions and coupling size can be exactly according to the specification requirements from the utilities.
?
3, The silicon rubber color of the insulators are also up to the requirements from the clients and all the silicon rubber materials past 5000 hours aging test silicon content test and hydrophobicity test.
?
4, ECR core rods are used in all the insulators, so we can guarantee a very good mechanical strength and anti-acid pollution performance for the insulators.
?
5, All our insulators were type tested and design tested in accordance with IEC61952, maximum RIV is 100μV when tested at 1MHz and10% over nominal line ground voltage for indicated system voltage.
?
6, All the Line Post Insulator with the voltage lower than 110kV are not supposed to use corona ring.
?
? ? All the Line Post Insulator with the voltage equal to or higher than 110kV but lower than 220kV are supposed to use one corona ring at the line end.
?
? ? All the Line Post Insulator with the voltage equal to or higher than 220kV are supposed to use two corona rings at both sides.
?
Applications:
?
1, All the 220kV(252kV) substations
?
2, All the220kV(252kV) Electric Power Lines
?
?
Competitive Advantage: