Home > Products > Line Post Insulator > 10kV Cross - Arm Line Post Insulator , Electric Power Line Insulator
10kV Cross - Arm Line Post Insulator , Electric Power Line Insulator
- T/T L/C D/P D/A
- 7 days
You May Like
-
IEC61109 Composite Suspension Insulator 35kv For High Land Transmission Lines
-
Silicon Rubber Composite Suspension Insulator 220kv High Flexibility
-
IEC 61109 Composite Suspension Insulator , 110kV Overhead Transmission Line Insulators
-
High Mechanical Strength Composite Suspension Insulator 330 Kv With Two Corona Rings
-
Long Rod Composite Suspension Insulator , 500kv Transmission Tower Insulators
-
Electric Transmission Line Cross Arm Insulator Composite 22kV / 24kV
Product Details
Brand Name | Changgong | Place of Origin | China | |
Model Number | FS-10/2.5-MJ-480 to FS-10/5-MJ-408 |
Product Description
Certification:KEMA STRI SGS
?
10kV Cross - Arm Line Post Insulator , Electric Power Line Insulator
?
?
Specifications:
?
Dimensions and Characteristics of 10kV Cross-arm Line Post Insulator
Figure. No | Model | Rated Voltage | Specified bending Mechanical Load | Section Length | Insulating length | Minimum Creepage | Full-Wave Impulse Withstand Voltage (Peak) | 1 Min Wet Power Frequency Withstand Voltage | Weight (for Reference) |
? | ? | kV | kN | H mm | h mm | L mm | ≥ kV | ≥ kV | kg |
2.5-1 | FS-10/2.5-MJ-480 | 10 | 2.5 | 480±5 | 320 | 400 | 150 | 60 | 1.9 |
2.5-2 | FS-10/5-MJ-408 | 10 | 5 | 408±5 | 243 | 380 | 150 | 60 | 2.9 |
Description:
?
1, 10kV Cross-arm Insulator are widely used in power transmission lines and substations.
?
2, Dead end fittings are up to the requirements from the clients, usually we use different flanges for post insulators with forged steel or cast steel. The dimensions and coupling size can be exactly according to the specification requirements from the utilities.
?
3, The silicon rubber color of the insulators are also up to the requirements from the clients and all the silicon rubber materials past 5000 hours aging test silicon content test and hydrophobicity test.
?
4, ECR core rods are used in all the insulators, so we can guarantee a very good mechanical strength and anti-acid pollution performance for the insulators.
?
5, All our insulators were type tested and design tested in accordance with IEC61952, maximum RIV is 100μV when tested at 1MHz and10% over nominal line ground voltage for indicated system voltage.
?
6, All the Cross-arm Insulators with the voltage lower than 110kV are not supposed to use corona ring.
? ? All the Cross-arm Insulators with the voltage equal to or higher than 110kV but lower than 220kV are supposed to use one corona ring at the line end.
? ? All the Cross-arm Insulators with the voltage equal to or higher than 220kV are supposed to use two corona rings at both sides.
?
?
Applications:
?
1, Usually used in 10kV substations
?
2, Usually used in 10kV Electric Power Lines
?
?
Competitive Advantage: