Home > Products > Solar PV Inverter > CE FCC Certificated dc12v to ac220v 230v 5000watt power solar inverter PV inverter
CE FCC Certificated dc12v to ac220v 230v 5000watt power solar inverter PV inverter
- T/T L/C D/P D/A
- 7 days
You May Like
-
IP 32 Solar Charger Controller 50A Intelligent Smart Solar Controller
-
High frequency Car Power Inverter dc 12v 24v 48v to 220v ac solar power inverter 300w 500w 1000w 200
-
12v 24v 48v Dc To Ac Sine Wave Car Power Inverter 2000w Automatic Shutdown
-
High efficiency off grid dc ac solar inverter 3000w inverter battery current adjustable
-
Overcharge Protection Solar Charger Controller 12v 15A PWM Solar Controller With CE & FCC
-
3000 watt inverter pure sine wave with AC charger / LCD Display
Product Details
Brand Name | ONE | Place of Origin | China | |
Model Number | FSI-50224M50 |
Product Description
Certification:CE FCC
CE FCC Certificated dc12v to ac220v 230v 5000watt power solar inverter PV inverter
FSI 50224
Continuous stable output voltage:
Top One: No matter how low or how high the AC input voltage is, with voltage stabilizer our inverter provides standard 110V or 220V stable output, which keeps the loading works stably. Wide stabilizing range of AC input optional.
----------------------------------
Others: Only a few inverter in the market has stabilizer technology, even they have, they can only provide short time stabilization but not continuously. So the loading can work in short time stably only but not long time. Or their stabilizing range is not wide as ours.
Model | FSI-102 | FSI-152 | FSI-202 | FSI-302 | FSI-402 | FSI-502 | FSI-602 | |
Rated Power | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | |
Peak Power | 3KW | 4.5KW | 6KW | 9KW | 12KW | 15KW | 18KW | |
Nominal battery voltage | 12/24VDC | 12/24/48VDC | 24VDC/48VDC | |||||
Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) | ||||||
AC Mains input range | 170-275VAC (220/230/240VAC)±4% | |||||||
AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz±0.5Hz (50Hz/60Hz automatic recognition) | |||||||
Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) alarm | ||||||
Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) automatic shutdown | |||||||
High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) alarm | |||||||
High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) automatic shutdown | |||||||
Over load protection | 110%<loading<150%, shutdown after 60s alarm, loading>150%, shutdown after 20s alarm | |||||||
High temperature | Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown | |||||||
Short circuit protection | Automatic shutdown | |||||||
Output | Transfer efficiency | ≥90% | ||||||
Output voltage | (DC battery mode) 220/230/240VAC±2% | |||||||
Output frequency | (DC battery mode) 60/50Hz±1% | |||||||
Output wave form | Pure sine wave | |||||||
Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) | |||||||
AVR output stablizer | AC mains<170VAC±5% swtich to DC battery mode, AC mains>180VAC ±5% return to AC mains mode; | |||||||
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; | ||||||||
The above is for output 220V system reference, 230V/240V output just multiply by percentage | ||||||||
Output frequency | (AC mains mode) automatic tracing from AC input | |||||||
Other | Transfer time | ≤5ms | ||||||
Display | LCD Display with function buttons | |||||||
Cooling system | Intelligent cooling fan control system | |||||||
≤42℃ slow fan, ≥45℃ fast fan | ||||||||
AC Charger | 7 battery types mode | Gel U.S.A. / Gel European / A.G.M.1 / A.G.M.2 / Sealed lead acid / Open lead acid / Calcium(open) / | ||||||
Deep sulphation cycle 15.5 for 4 hrs | ||||||||
AC charging Voltage | 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V) | |||||||
AC charging current | 0-35A: 5A / 10A / 20A / 25A / 30A / 35A, 6 stages adjustable option | |||||||
3 Stages charging | Boost charging, direct charging, float charging | |||||||
AC over charge protection | Battery voltage ≧16VDC (12V) ≧32VDC (24V) ≧64VDC (48V), stop charging after 60s alarm | |||||||
Working mode (Optional) |
01 | AC mains priority | ||||||
Always use AC mains as priority input to provide AC
Contact Us
Product CategoriesNew Products
Popular Searches
Recommended Products
We will find the most reliable suppliers for you according to your description. Send Now
Foshan Top One Power Technology Co., Ltd
AIBot OnlineThis conversation is AI-generated. Contact manufacturer before transaction to confirm info.
Your message has exceeded the limit. ![]()
Your message has exceeded the limit.
|