Brand Name | ONE | Place of Origin | China | |
Model Number | FSI-40248M50 |
Product Description
Certification:CE FCC
Low frequency pure sine wave dc 12v to ac 220vac 1kv 2kv 3kv 4kv power solar inverter
FSI-40248M50
DSP smart chip Core: An individual 64-bit DSP control chip, more text samples and control functions
The detection and control program is written into the DSP chip. The results are fetched by DSP chip and the inverter is controlled by DSP chip. The advantage is that the value is accurate(by effective value). Tolerance is less than 0.01%
Most of inverters in the market are controlled by hardware circuit.
Disadvantages:
1.Components will have the ageing problems.
2.Complicated production processes, full of wires, which will raise not only the manual defects during production and after sales problem.
Top One VS Other inverter factory
Photoelectricity isolation circuitry technology:
Top One: It can detect and modulate the pulse width of boost circuit, reduce the EFT(Electric Fast Transient) and raise anti-interference.
Ohters: The inverter without this function. Which will cause high EFT(Electric Fast Transient) and low anti-interference.
Model | FSI-102 | FSI-152 | FSI-202 | FSI-302 | FSI-402 | FSI-502 | FSI-602 | |
Rated Power | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | |
Peak Power | 3KW | 4.5KW | 6KW | 9KW | 12KW | 15KW | 18KW | |
Nominal battery voltage | 12/24VDC | 12/24/48VDC | 24VDC/48VDC | |||||
Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) | ||||||
AC Mains input range | 170-275VAC (220/230/240VAC)±4% | |||||||
AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz±0.5Hz (50Hz/60Hz automatic recognition) | |||||||
Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) alarm | ||||||
Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) automatic shutdown | |||||||
High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) alarm | |||||||
High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) automatic shutdown | |||||||
Over load protection | 110%<loading<150%, shutdown after 60s alarm, loading>150%, shutdown after 20s alarm | |||||||
High temperature | Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown | |||||||
Short circuit protection | Automatic shutdown | |||||||
Output | Transfer efficiency | ≥90% | ||||||
Output voltage | (DC battery mode) 220/230/240VAC±2% | |||||||
Output frequency | (DC battery mode) 60/50Hz±1% | |||||||
Output wave form | Pure sine wave | |||||||
Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) | |||||||
AVR output stablizer | AC mains<170VAC±5% swtich to DC battery mode, AC mains>180VAC ±5% return to AC mains mode; | |||||||
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; | ||||||||
The above is for output 220V system reference, 230V/240V output just multiply by percentage | ||||||||
Output frequency | (AC mains mode) automatic tracing from AC input | |||||||
Other | Transfer time | ≤5ms | ||||||
Display | LCD Display with function buttons | |||||||
Cooling system | Intelligent cooling fan control system | |||||||
≤42℃ slow fan, ≥45℃ fast fan | ||||||||
AC Charger | 7 battery types mode | Gel U.S.A. / Gel European / A.G.M.1 / A.G.M.2 / Sealed lead acid / Open lead acid / Calcium(open) / | ||||||
Deep sulphation cycle 15.5 for 4 hrs | ||||||||
AC charging Voltage | 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V) | |||||||
AC charging current | 0-35A: 5A / 10A / 20A / 25A / 30A / 35A, 6 stages adjustable option | |||||||
3 Stages charging |