Place of Origin | Guangdong, China | Brand Name | Graigar | |
Model Number | ETCR3000B | Display Type | Digital Only | |
Measuring Range | 0.00Ω-30.00kΩ | Testing Voltage | 0V~40V | |
Operating Temperature | 25C | Dimensions | 45X35X20 |
Product Description
Specifications
HOT SALE ! ETCR3000B Earth Resistance Soil Resistivity Tester
HOT SALE ! ETCR3000B Earth Resistance Soil Resistivity Tester
ETCR3000B Earth Resistance Soil Resistivity Tester is specially designed and manufactured for measuring earth resistance, soil resistivity, earth voltage, AC voltage. Adopting the latest digital and micro-processing technology, precise 4-pole, 3-pole and simple 2-pole method for earth resistance measurement, importing FFT and AFC technology, with a unique function of anti-interference capability and the ability to adapt to the environment, consistency of repeat testing, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth resistance, soil resistivity, earth voltage, AC voltage measurement.
ETCR3000B Earth Resistance Soil Resistivity Tester is composed of host machine, monitoring software, testing wires, auxiliary ground pillars, communication wires and others. The large LCD display of host machine is with blue backlight and bar graph indicating that can be seen clearly. At the same time it can store 300 sets of data, fulfilling historical inquiry and online real-time monitoring through monitoring software, dynamic display, alarm indicator, and with the functions like historical data access, reading, preservation, report forms, printing and so on.
II Technical Specifications
1. Base Conditions and Working Conditions
Influence Quantity | Base Condition | Working Conditions | Remark |
Ambient Temp | 23C±1C | -10C-40C | ---- |
Ambient Humidity | 40%-60% | <80% | ---- |
Working Voltage | 9V±0.1V | 9V±1.5V | rC rP |
Auxiliary Earth Resistance | <100Ω | <30kΩ | ---- |
Interference Voltage | no | <20V | ---- |
Interference Current | no | <2A | |
Electrode Distance when measuring R | a>5d | a>5d | ---- |
Electrode Distance when measuring ρ | a>20h | a>20h | ---- |
2. General Specification
Function | Measurement of 2/3/4-pole earth resistance, soil resistivity, earth voltage, AC voltage |
Power Supply | DC 9V(Zi-Mn dry battery R14S 1.5V 6 PCS, continuous standby for 300 hours ) |
Measurement Range | Earth Resistance: 0.00Ω-30.00kΩ |
Soil Resistivity: 0.00Ωm-9000kΩm | |
Measuring Mode | Precise 4-pole measurement, 3-pole measurement, simple 2-pole measurement |
Measuring Method | Earth Resistance: rated current change-pole method, measurement current 20mA Max Soil Resistivity: 4-pole measurement (Wenner method) Earth Voltage: average rectification(between P(S)-ES) |
Test Frequency | 128Hz/111Hz/105Hz/94Hz(AFC) |
Short-circuit Test Current | AC 20mA max |
Open-circuit Test Current | AC 40V max |
Test Voltage Wave | Sine wave |
Electrode DistanceRange | Can be set 1m-100m |
Shift | Earth Resistance: 0.00Ω-30.00kΩ, automatic shift |
Soil Resistivity: 0.00Ωm-9000kΩm, automatic shift | |
Backlight | Blue screen backlight, suitable for dim places |
Display Mode | 4-digital super-large LCD display, blue screen backlight |
Measuring Indicator | During measurement, LED flash indicator, LCD count down display, progress bar indicator |
LCD Frame Dimension | 128mm×75mm |
LCD Window Dimension | 124mm×67mm |
Dimension | L×W×H: 215mm×190mm×95mm |
Standard Test Wire | 4 wires: each for red 20m, black 20m, yellow 10m, and green 10m |
Simple Test Wire | 2 wires: each for red 1.6m and black 1.6m |
Auxiliary Earthing Rod | 4 rods: Φ10mm×150mm |
Measuring Rate | Earth voltage: about 3 times/second |
Earth resistance, soil resistivity: about 5 seconds/time | |
Measuring Times | Over 5000 times (Short-circuit test, interval time should be at least 30 seconds) |
Line Voltage | below AC 600V |
RS232 Interface | Possess RS232 interface, software supervision, storage data can be uploaded to computer, saved or printed. |
Communication Wire | One piece of RS232 communication wire, with length 1.5m |
Data Storage | 300 sets, “MEM” icon storage indicator, flash display “FULL” icon to indicate storage is full |
Data Hold | Data hold function: “HOLD” icon display |
Data Access | Data read function: “READ”icon display |
Overflow Display | Exceeding measuring range overflow function: “OL” icon display |
Interference Test | Recognize interference signal automatically, “NOISE” icon display when interference voltage exceed 5V |
Auxiliary Earthing Test | Can measure auxiliary earth resistance, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ) |
Alarm Function | When measuring value exceeds alarm setting value, there is “Toot-toot-toot” alarm hint |
Battery Voltage | When battery voltage decreases to about 7.5V, battery voltage low icon will display, reminding to replace battery. |
Power Consumption | Standby: about 20mA (Backlight shut off) |
Boot and with backlight: about 45mA (25mA without backlight) | |
Measurement: about 100mA (Backlight shut off) | |
Weight | Total weight: 4.5kg (including package) |
Tester: 1443g (including battery) | |
Tesing wires: 1560g | |
Auxiliary earthing rods: 935g (4pcs) | |
WorkingTemperature & Humidity | -10C-40C, below 80%rh |
Storage temperature & humidity | -20C-60C, below 70%rh |
Overload Protection | Measuring earth resistance: between each interfaces of C(H)-E P(S)-ES,AC 280V/3 seconds |
Insulation Resistance | Over 20MΩ (between circuit and enclosure it is 500V) |
Withstanding Voltage | AC 3700V/rms (Between circuit and enclosure) |
Electromagnetic Features | IEC61326(EMC) |
Protection Type | IEC61010-1 (CAT III 300V CAT IV 150V Pollution 2), IEC61010-031, IEC61557-1 (Earth resistance), IEC61557-5 (Soil resistivity), JJG 366-2004 |
3. Intrinsic error and performance indicators under base conditions
Category | Measurement Range | Intrinsic Error | Resolution |
Earth Resistance (R) | 0.00Ω-30.00Ω | ±2%rdg±3dgt | 0.01Ω |
30.0Ω-300.0Ω | ±2%rdg±3dgt | 0.1Ω | |
300Ω-3000Ω | ±2%rdg±3dgt | 1Ω | |
3.00kΩ-30.00kΩ | ±4%rdg±3dgt | 10Ω | |
Soil Resistivity (ρ) | 0.00Ωm-99.99Ωm | According to the precision of R (ρ=2πaR a:1 m-100m, π=3.14) | 0.01Ωm |
100.0Ωm-999.9Ωm | 0.1Ωm | ||
1000Ωm-9999Ωm | 1Ωm | ||
10.00kΩm-99.99kΩm | 10Ωm | ||
100.0kΩm-999.9kΩm | 100Ωm | ||
1000kΩm-9000kΩm | 1kΩm | ||
Earth Voltage | AC 0.0-600V | ±2%rdg±3dgt | 0.1V |
IIIAccessories
Tester | 1 PC |
Tester Bag | 1 PC |
Auxiliary Earthing Rod | 4 PCS |
Standard testing Wire | 4 wires: each for red 20m, black 20m, yellow 10m, and green 10m |
Simple testing Wire | 2 wires: each for red 1.6m and black 1.6m |
Zinc-manganese Dry Battery | 6 PCS (R14S 1.5V) |
Monitoring Software Disk | 1 Copy |
RS232 Communication Cable | 1 PC |
Manual/Warranty Card/Qualification Certificate | 1 Copy |
Contact Us
- Shenzhen Graigar Technology Co., Ltd.
- Contact nameLeo Lee Chat Now
- Phone86-755-27541660
- AddressShajing Street,Baoan District, Shenzhen, Guangdong
Product Categories
New Products
-
ETCR4400 - three-phase digital phase position voltage / ampere meter
-
TM-196 _ 3 - Axis RF Field Strength Meter
-
ST332B ADSL2+ Tester/ADSL Tester / xDSL Tester / DSL Tester
-
YF-508A_Milliohm Meter. FREE SHIPPING
-
60W analog soldering station BK936ESD Soldering station AC220V 50HZ
-
2000W Digital Heating Gun BK8020 Rework tools 250L-500L/Min
-
1600W Digital Heating Gun BK8016 Rework tools Temperature Adjustable Temperature Digital Display
-
Economical Digital Rework Station BK870A Rework tools 180~480C
-
Economical Hot Air Rework Station SBK850B Rework tools 100~420C
-
TDS-100H ultrasonic flow meter & flowmeter water flow meter digital ultrasonic flow meter
-
PGas-22 Portable Combustible Gas Detector
-
PGas-23 Portable Combustible Gas Detector,gas detector, portable gas detector
-
PGas-32 Portable Infrared Gas Detector,Portable Combustible Gas Detector, Refrigerant Leak Detectors
-
PGas-31 Infrared Gas Detector,Portable Combustible Gas Detector, Refrigerant Leak Detectors, SF6 Gas Detector, Carbon Monoxide
-
PGas-24 Portable Combustible Gas Detector,portable multi gas detector
-
PGas-21 Portable Single Gas Detector,Portable Combustible Gas Detector, Refrigerant Leak Detectors, SF6 Gas Detector,
-
SF6 Gas Detectors AR5750B,Portable Combustible Gas Detector, Refrigerant Leak Detectors, SF6 Gas Detector, Carbon Monoxide Meter
-
Combustible Gas Detector SPD202/Ex,Refrigerant Leak Detectors, SF6 Gas Detector, Carbon Monoxide Meter,
-
PH-009(I) Pocket-size PH meter
-
PH-009(II) Pocket-size PH meter,ph meter,ph tester
-
PH-009(III) High Accuracy Pen-type PH meter,ph tester,digital ph meter
-
PH-061 Pen-type PH Meter with CE certificate, ph meter,ph tester,orp tester
-
PH-03(I) High Accuracy Pen-type PH Meter with CE certificate, cheap price
-
PH-03(II) High Accuracy Pen-type PH Meter with CE certificate, cheap price, lower cost
Popular Searches
Recommended Products
- Acrel AIM-M200 Medical Intelligent Insulation Monitoring Device For IT System ICU CCU With Alarm Output Hospital Isolation
- Acrel AIM-M200 Medical Intelligent Insulation Monitoring Device For IT System ICU CCU With Alarm Output Hospital Isolation
- Insulation Monitoring Device Acrel AIM-M200 Hospital Insulation Monitoring Device Accurate Insulation Resistance Monitoring
- Acrel AIM-M200 Hospital Insulation Monitoring Device Accurate Insulation Resistance Monitoring
- Acrel AIM-M200 Insulation Monitoring Device For IT System/Electric Insulation Monitoring Device
- hospital isolation transformer system insulation monitoring device
- medical IT system hospital isolation transformer system insulation monitoring device insulation fault locator
- acrel AIM-M200 medical IT system hospital isolation transformer system insulation monitoring device insulation fault locator
- insulation monitoring device for IT systems
- Digital display DC Low Resistance Tester Low value resistance tester
- Digital earth resistance tester ground resistance meter soil resistivity test
- Double clamp grounding resistance tester soil resistivity ground voltage DC voltage and AC current
Find Similar Products By Category
- Instruments & Meters > Meter for Electricity > Resistance Meter
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now
Shenzhen Graigar Technology Co., Ltd.
AIBot OnlineThis conversation is AI-generated. Contact manufacturer before transaction to confirm info.
-
Leo Lee
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile