Home > Products > Three Phase Power meter > Acuvim II Series three phase meter
Acuvim II Series three phase meter
- Beijing
- D/P D/A
You May Like
-
Acuvim II Series DIN rail multifunction meter, RS485 Modbus,Big LCD display
-
Acuvim II Series three phase Din rail power meter
-
Acuvim II Series Power meter,good price,RS485,
-
Acuvim II Series three phase multi-functions smart din rail power meter with RS485 MODBUS
-
Acuvim II Series Three phase Multi-functions Smart Din rail energy meter with RS485 MODBUS
-
Acuvim II Series digit digital panel meters
Product Details
Place of Origin | Beijing, China | Brand Name | Accuenergy | |
Model Number | Acuvim II Series | Measuring Current Range | 5mA~50000A | |
Measuring Voltage Range | 20V~500kV | Accuracy Class | 0.2s | |
Operating Temperature | -25℃~70℃ | Dimensions | 96x96x65mm |
Product Description
Specifications
1. Acuvim II Series Power Meter2. DIN Rail mount
3. TOU, 4 Tariffs,
4. Revenue Grade with DATA-LOGGING
5. UL, cUL and CE
DESCRIPTION
The Acuvim II is three phase meter by Accuenergy. It is the ideal choice for monitoring and controlling of power distribution systems. Some of the features and electric power parameters available on the compact Acuvim II are:
- TOU, 4 Tariffs, 12 Seasons, 14 Schedules
- Data-Logging
- Module Design
- Measure Individual Harmonics from 2 to 63 (Acuvim IIR, Acuvim IIE)
- Remote Switch Controlling
- Switch Status Monitoring
- Web Server and Email Sending
- Multi Communication Ports (Eg: Ethernet, RS485)
- Over/Under Limit Alarm
- Power Quality Analysis
- ANSI C12.20(0.2 Class) and IEC 62053-22(0.2S Class)
- True-RMS Measuring Parameter
- Metering of distribution feeders, transformers, generators, capacitor banks and motors
- Medium and low voltage systems
- Commercial, industrial, utility
- Power quality analysis
- Data Logging
- Voltage V1, V2, V3, Vlnavg, V12, V23, V31, Vllavg
- Current I1, I2, I3, In, Iavg
- Power P1, P2, P3, Psum
- Reactive Power Q1, Q2, Q3, Qsum
- Apparent Power S1, S2, S3, Ssum
- Frequency F
- Power Factor PF1, PF2, PF3, PF
- Energy Ep_imp, Ep_exp, Ep_total, Ep_net
- Reactive Energy Eq_imp, Eq_exp, Eq_total, Eq_net
- Apparent Energy Es
- Demand Dmd_P, Dmd_Q, Dmd_S, Dmd_I1, Dmd_I2, Dmd_I3
- Load Features
- Four Quadrant Powers
Monitoring
- Power Quality
- Voltage Harmonics 2nd to 63rd and THD
- Current Harmonics 2nd to 63rd and THD
- Voltage Crest Factor
- THFF (TIF)
- Current K Factor
- Voltage Unbalance Factor U_unbl
- Current Unbalance Factor I_unbl
- Max/Min Statistics with Time Stamps
Fexible I/O module
The E-moduleR technique was adopted for its flexibility and easy expansion of the I/O function of Acuvim II. A maximum of 3 modules can be used for one meter. Digital input, Digital output, pulse output, relay output, analog input and analog output are provided by I/O option module.
Communication
- RS485, Industry standard ModbusRprotocol
- Module Option: Ethernet module, Profbus-DP module
- Dual RS485 communication ports
- RS-485 (Standard): MODBUS RTU Protocol, 2-wire connection, Up to 38400 baud rate
- Ethernet (Optional): 10M/100M BaseT, MODBUSR TCP/IP Protocol, Data Browsing through HTTP, Sending e-mail automatically
- PROFI-BUS (Optional): PROFIBUS-DP/V0 Protocol; Work as PROFIBUS slave, baud rate adaptive, up to 12M; Typical input bytes: 32, typical output bytes: 32; PROFIBUS standard according to EN 50170 vol.2
The limits of the less than 9 indicated parameters can be set with a specified, time interval. If any input of the 9 indicated parameters is over or under its setting limit with persisting time over specified time interval, the event will be recorded with time stamps and trigger the Alarm DO output. The 9 indicated parameters can be any of the following 34 ones. F, V1, V2, V3, Vlnavg, V12, V23, V31, Vllavg, I1, I2, I3, Iavg, In, P1, P2, P3, Psum, Q1, Q2, Q3, Qsum, S1, S2, S3, Ssum, PF1, PF2, PF3, PF, U_unbl, I_unbl, Dmd_P, Dmd_Q, Dmd_S
Data_logging
The Acuvim IIR, Acuvim IIE, model offers 4MB of onboard data logging memory to be used for historical trending. There are 3 assignable historical logs where the majority of the metering parameters can be recorded. A real time clock allows for any logged events to be accurately time stamped.
Display
Clear and large character LCD Screen display with white back light
Wide environmental temperature endurance
Display Load percentage, 4 quadrants power and load nature
Certificate
- CE
- UL
Contact Us
- Accuenergy Technology Co., Ltd.
- Contact nameHoward Wang Chat Now
- Phone1-877-721 8908
- AddressNo. 12 Yard, Fengrun East Rd.
Product Categories
Communications | Current Transformers | Multi-Circuit Power and Energy Meters | Multifunction DC Power Meter |
New Products | Single Phase Power Meter | System Solutions | Three Phase Power meter |
New Products
-
Acuvim II Series din rail energy meter
-
Acuvim II Series power panel
-
Acuvim II Series quality meter
-
Acuvim II Series hour meter
-
Acuvim II Series digital panel meter
-
Acuvim II Series digital panel meter
-
Acuvim II Series multimeter
-
Acuvim II Series power meter
-
Acuvim II Series smart electric meters
-
Acuvim II Series modbus power meter
-
Acuvim II Series power panel meter
-
Acuvim II Series din rail meter
Popular Searches
- digital electric meter hack
- ami system
- activate electric
- activate electrical
- activate measurement
- activate measurements
- ac energy meter
- a d power meters
- electronical meter
- convenience installer
- power measuring
- display din
- digital swr
- electric analyze
- electric sub
- electron meter
- electrone logos
- electronics meters
- electronics meter
- elecrical
- elecric
- energie powered monitor
- lcd din
- moon phase mechanics
- quality ae
- read instrument
- registered energy
- sound level meter logger
- standard sts
- uv energy
Recommended Products
- Wifi Smart energy Meter
- Smart Energy Meter Single phase LCD Display
- Din rail Energy Meter Single phase
- PIU2000A 0.01% Grade high precision DC Tester
- Industry-Leading Support Acrel DJSF1352-RN/S RS485 Modbus-RTU Communication Din Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate/0.5S accuracy shunt connect
- Innovative Design Acrel DJSF1352-RN/2C RS485 Modbus-RTU Communication Din Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate/second channel RS485
- Reliable Performance Acrel DJSF1352-RN/D Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate/second channel DC measurement RS485 Modbus-RTU Communication
- Precise Monitoring Acrel DJSF1352-RN/K RS485 Modbus-RTU Communication Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate/2DI+2DO
- Acrel DJSF1352-RN Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate RS485 Modbus-RTU Communication
- Acrel ADW300/L 1 channel of residual current measurement Din rail smart electrical meter to monitor, collect and manage electricity
- Acrel ADW300/T 4 channel temperature measurement Din rail smart electrical meter to monitor, collect and manage electricity
- Acrel ADW300/K 4DI+2DO Din rail smart electrical meter to monitor, collect and manage electricity
Find Similar Products By Category
- Instruments & Meters > Meter for Electricity > Energy Meter & Power Meter
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Howard Wang
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile