Place of Origin | China | Brand Name | PULANI | |
Model Number | 2013PLN-YT | Power | Electronic | |
Usage | Other, Measure coating thickness on metal surface paint |
Product Description
Basic instructions:
1 . Automatic shutdown time: 30s
2.There are 4 kinds of state mode : measurement status, Statistics status, view data
status , calibration status.
A) Measurement status: display of measured values.
B)View data status :20 sets of historical data through.
C) Statistics status: maximum, minimum, average value.
D) Multi-point Calibration status :
F) Auto Calibration status : calibration measurements, and the gauge has 6 kinds of
calibration mode of 0.0 um, 50um, 100 um,250um ,500 um.
Key function instructions
K1 (+) function :
A :Short press K1 (+), When you in different status, it will show you different function as
below :
1) In the measurement status,short press “+”, the unit will be switch from um to mil .
2) In the view data status,short press “+”, it can turn up to show the data .
3)In the statistics status of “MAX” ,short press “+”,the background light will be off .
4)In the calibration status, short press”+”,it can switch 6 kinds of calibration mode of 0.0 um,
50um, 100 um,250um ,500 um in turn.
B: long press K1(+), When you in different status, it will show you different function as
below :
1)In the measurement status, long press “+”, it will enter to the multi-point calibration mode
2)In the view data status, long press “+”, delete a single data selected
3)In the statistics status of “MAX”, long press “+” , it could be light on /off the background
light, but if the screen is black one ,you can not see the data.
4)In the auto calibration status: exit the calibration status to the measuring status
K2 (MENU)function
A: short press K2(menu),When you in different status, it will show you different function as
below :
1)In the Non-calibration status: measurement status, view data status and statistics status
be switched in turn.
2)In the both of auto and multi-point calibration status: exit the calibration status to the view
data status
B: long press K2(menu),When you in different status, it will show you different function as
below :
1)In the auto measurement status: enter the auto calibration status
3)In the statistics status and View data status: invalid
K3 (-)function
A: short press K3 (-)
1)View data status: turn down to show the data
2)Statistics status: invalid
3)The calibration status: switch 6 kinds of calibration mode of 0.0 um, 50um, 100
um,250um ,500 um in turn .
B: long pressK3 (-):
1)In the Measurement status: restore factory (it will removal of historical data and the
calibration parameters) .
2)In the View data status: clear the historical data (including 20 measurements, the
maximum, minimum and average), the calibration parameters keep constant.
3)In the Statistics status: invalid
4)In the calibration status: exit the calibration status to the measuring status
5 pcs gauges you received are with sample package. Now there are 2 types of regular package:
(1) 1 complete set of gauge package: 1 pcs gauge, 1 set calibration, 1 instruction, 1 black glasses box.
(2) 5 complete sets of gauge package: 5 pcs gauge, 5 sets calibration, 5 instructions, 5 black glasses boxes, 1 white carton box whose outside is with the color cover.
Payment
1. We can accept T/T and western union and Money Order,paypal is just for sample fee.The best way is direcet online payment,you can choose yourself.If you want other payment terms please let us know before when you order.
2. Make sure that you have completed all the detailed information like contact person,address,post code and telphone number when filling in your buyer's information.
Shipping
Note:DHL/UPS/Fedex Express usually takes about 3-7 working days to the destination,and it's about 5-8 working days by EMS or TMT(except Russia,which will be delay for 15-30 days).HK Post and CN Post or SG Post takes 7-30 days to ship to worldwide.
1. We will send the goods within 3 business days after the full payment has been confirmed.If the payment is not available,your order will be closed automatically.
2. The buyers are responsible for any insurance,problems and damage which caused by shipping service such accidents,delays or other issues.Besides the buyer should to be responsible for any tax and/or duty charged by their country. (If you want to declare the goods as other item name,or specify an value for custom,please inform us when making the order.we could according to your detail desire for your easy customs clearance and less charge.)
Feedback
1 Buyers early confirmation will be highly appreciated after receiving the items.
2 Since your feedback is very important to our business's development,we sincerely invite you to leave positive feedback for us if you are satisfied with our product and service.It'll just take you 1 minute,but this 1 minute has the extemely vital significance to us.
What we can do
1 All of our products have proceeded again test before shipment and we guarantee to use our products safety.
2 Support imprint your logo on products and let your logo shine anywhere.
3 OEM orders are warmly welcome!
Warranty and Return
1. All products and accessories have been tested by 3 times before ship out. And all products have 1 year warranty. If there is no man-made problem, you can return back the goods for replace a new one , but your side need share the return back delivery cost, and we will share the shipping cost to your side agian .
2. We own the best after-sale service.If any problems happen,our team will do our best to solve for customers.
3. All return items must be in its original conditions,including box and accessories.Men made defects are not guaranteed,such as broken,scratched and so on.
4 For any items,please send by DHL,Fedex or your local express or post when send back .
1) How the coating thickness gauge shut down?
A: Our coating thickness gauge adopt with automatic shutdown, when you stop using it, it will be shutdown automatic after 30 seconds.
2) What angle should be kept with Coating thickness with the analyte ?
A: The probe must be kept perpendicular to the surface with the measured material, otherwise it will lead to considerable error.
3) How to maintain accuracy of measurement when we need repeatedly measurements ?
A: When we need repeatedly measure, the thickness gauge should be keep the distance more than 3cm away from the analyte and at least keep 2 seconds or more interval .(Attention :Do not drag along the surface to the side of the probe to avoid probe magnetization.it will be impact of next measurement result)
4) When should we to calibrate the Coating thickness ?
A: Our thickness gauge has been calibrated , in most time, we just need to check whether the uncoated substrate is normalized to zero .Usually when the measurement accuracy beyond the precision values ,it need to be calibrated (refer to the instructions precision value range) . Calibration method according to operating instructions.
5) When the Coating thickness display with"" ,What does it mean?
A: It indicates that the battery voltage is low, please replace the battery in the automatic shutdown, otherwise it will affect the measurement accuracy.
6) How to choose the zero substrate?
A: The thickness of zero substrate should be used as the test material to avoid the permeability of different materials and measurement errors.
7) How to choose the zero substrate surface?
A: Use the gauge should be in the same part of the material being tested after calibrating to zero, and then measuring the same part. If the measuring pipe, bar and other curve surface materials, but the user indeed calibrating to zero with substrate of flats surface , this will affect the accuracy of the measurement. And choose the calibrating zero surface should be more smooth.
8) Coating thickness gauge has been calibrated, why also the measurement also not accurately?
A: The coating thickness calibration could not choose the substrate random ,firstly calibrating to zero based on the same test material of substrate which without coating , then put the calibration sheet in the top to calibrate, so that could get reliable measurement data. Remember: Be sure to use the same shape, the same material, the same roughness zeroing calibration substrate.
9) Why the different coating thickness measured data is not the same?
A: Due to different coating thickness gauge calibrated with different substrate before use . For consistency, we should make them in the same uncoated substrate to do the zero calibration, and then put the calibration sheet in the top to calibrate, so different coating thickness measurement data will be keep consistent.
10) When should we to replace to Standard film ?
A: The coating thickness calibration depends on the calibration sheet, so it is very important that keep the calibration sheet in good condition. If the calibration sheet has been used for many years and not in a good condition, please replace it . Otherwise, the measurement data will be inaccurate.
Contact Us
- Hangzhou Pulani Electronic Technology Co., Ltd.
- Contact nameDemi Guo Chat Now
- Phone86-571-85829611
- AddressBlock D,Floor 14th ,Chunxiao Court,Zhongshan Garden, No. 221, Zhaohui Road, Hangzhou, Zhejiang
Product Categories
Automobile & Motocycle Electronic Products | Industrial Measuring & testing Instruments | New Products |
New Products
-
widely measuring range of 1500um digital non-destructive paint coating thickness inspection equipment
-
Handheld digital magnetic paint coating thickness meter gauge with 1300um range
-
Digital car paint coating thickness gauge meter built-in F/NF probes
-
With USB interface coating thickness meters gauges with 1300um
-
Dual function built in ferror and non-ferror probe coating thickness meters gauges
-
Made in China coating thickness gauge meter tester for automobile maintenance industry
-
Made in China coating thickness gauge meter tester for automobiles and motorcycls' paint
-
Made in China coating thickness gauge meter tester
-
Made in China oating thickness gauge
-
Built-in F &NF probe digital paint thickness gauge
-
Popular car coating thickness inspection equipment
-
car paint coating thickness measuring tester
-
China manufacture metal paint coating thickness gauge detector
-
Built in Fe and NFE probe which could automatic identification paint thickness test gauge on metal
-
1500um car paint coating thickness measurement gage instrument
-
2% accuary, 1500um car paint coating thickness measurement instrument
-
Easily view the historical data digital car paint thickness gauges meter
-
Magnetic induction and eddy current probe digital car paint thickness gauge
-
High accurancy auto paint coating thickness measurement instruments
-
portable iron and aluminum coating tester
-
portable widely used for metal paint coating test tool
-
easy operate hand tool of car paint coating meter
-
Most easy operate digitall thickness tester with easy operate three button
-
Only Three button metal digitall thickness tester
Popular Searches
- digital tester
- Resistance Tester
- electrical instrument
- test instrument
- lab equipment
- analysis instrument
- laboratory instrument
- Asphalt Mixture Mixer
- launch x431 master
- x431
- Gloss Meter
- Resistance Meter
- digital instrument
- dc load bank
- testing equipment
- testing machine
- battery load bank
- Circuit Tester
- Impact Tester
- lab instrument
- weather station
- gps receiver
- laboratory instruments
- test equipment
- laboratory equipment
- electronic timer
- electronic meter
- electronic instrument
- Electricity Meter
- data collector
Recommended Products
- ore reduction equipment cheap small jaw crusher lab size reduction machine
- wholesale lab crusher rock crushing machine high quality lab jaw crusher
- small capacity crusher portable lab jaw crusher mineral processing equipment
- mini jaw crusher for sale lab grinding machine lab crusher equipment supplier
- laboratory testing machine laboratory crusher manufacturer primary crushing equipment
- lab jaw crusher supplier sample preparation equipment small jaw crusher price
- mini industrial crusher ceramic laboratory crusher wear-resistant jaw plates
- 100x100 laboratory crusher coal sample jaw crusher high reduction ratio jaw crusher
- 100x60 jaw crusher concrete lab crusher compact design jaw crusher
- compact jaw crusher laboratory geological sample crusher
- small scale jaw crusher material testing jaw crusher dust-free jaw crusher
- lab size jaw crusher ore laboratory crusher low noise lab crusher
Find Similar Products By Category
- Instruments & Meters > Test Instrument > Test Machine
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Demi Guo
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile