Home > Products > Surge protection device > Experienced factory for electric suppressor with type test report
Experienced factory for electric suppressor with type test report
- Ningbo or shanghai
- T/T Credit Card
You May Like
-
ISO certificated factory for transient voltage surge suppressor in Wenzhou Quality Choice
-
High Voltage Fuse Links for dropout fuse cutout (carton type)
-
K type 16A HV FUSE LINK
-
Fuse holder for 24kV cut cut fuse
-
Dropout fuse (12-15KV) / silicon rubber or porceilain
-
11kv cutout fuse / porcelain drop out fuse 200A
Product Details
Place of Origin | Zhejiang, China | Brand Name | DGMDQ ( electric suppressor) | |
Model Number | DGM4-B40/4( electric suppressor ) |
Product Description
Experienced factory for electric suppressor with type test report
1.Pictures Experienced factory for electric suppressor with type test report
2. Description Experienced factory for electric suppressor with type test report
The products comply with IEC61643-1, GB18802.1.
The housing is fixed on 35mm electrical guide, and with failure release device inside. As long as SPD become invalid after the breakdown caused by over-heat and overload current, the failure release device will be disengaged from power system automatically with the warning indicator turning from Green (normal) to Red (failure).
SPD is usually installed in household power distribution boards, telecom machinery center, computer equipment center, elevator control center, hospital's surgery and ICU, information equipment, electronic equipment and in front of control equipment or nearest socket box of control equipment. Experienced factory for electric suppressor with type test report
TECHNICAL DATA | ||||||||
DGM-B400/4 | ||||||||
Rated voltage | Un | 220V/380V AC | ||||||
ntinuous operatiing voltage | Uc | 275/320/385/420V AC | ||||||
Nominal discharge current 8/20μs | In | 40 kA | ||||||
Max.discharge current 8/20μs Imax | Imax | 80 kA | ||||||
Voltage protection level Up | Up | <2.5 kV | ||||||
Response time | tA | <25 ns | ||||||
Max. back-up fuse | 100 AgL/gG | |||||||
Short-circuit withstand capability | Ip | 25kArms | ||||||
Temporary overvoltage (TOV) N/PE | UT | 1200 V/0,2 sec | ||||||
Housing material | thermoplastic, UL 94 V-0 | |||||||
Operating temperature | Tu | -40°C…+80°C | ||||||
Relative Humidity | <90% | |||||||
Altitude | <2000M | |||||||
Housing Color | Gray white | |||||||
Degree of protection | IP20 | |||||||
Function display( visible window ) | Normal : Green Failure: Red | |||||||
Adapt to | TT,TN,IT system | |||||||
For mounting on | 35 mm DIN rail acc. to EN 60715 | |||||||
Cross-sectional area (min.) | 4 mm2 solid/flexible | |||||||
Cross-sectional area (max.) | 25 mm2 flexible | |||||||
Net weight | m | 1.1kg | ||||||
Packaging dimensions(15pcs) | 400x300x160mm |
3. Our certificate Experienced factory for electric suppressor with type test report
Test report Experienced factory for electric suppressor with type test report
Experienced factory for electric suppressor with type test report
1. Introduction Of Company Experienced factory for electric suppressor with type test report
2. We are the manufacturer Experienced factory for electric suppressor with type test report
3. Contact us Experienced factory for electric suppressor with type test report
Contact Us
- Zhejiang Leishu Electric Co., Ltd.
- Contact nameNancy Ni Chat Now
- Phone86-577-62679111
- AddressOriginal Lilong Primary School, Lilong Village, Qiligang Town
Product Categories
New Products
-
35 KV Drop-out fuse for high voltage
-
35 KV Drop-out fuse for high voltage
-
Silicon Drop-out fuse for high voltage
-
10 KV Drop-out fuse for high voltage
-
10 KV Drop-out fuse for high voltage
-
Drop-out fuse for high voltage
-
HV Drop-out fuse
-
fuse types / drop out fuse / cut out fuse
-
27KV AC High-voltage Drop Out Fuses/Porcelain or Polymeric Metal Oxide fuse cutout
-
33KV Drop-out Fuse
-
11KV Fuse
-
10KV drop out fuse cut cut high voltage
-
Drop-out Fuse / Cutout fuse / Metal oxide
-
12kv Drop Out Fuse / Fuse Cutout / porcelain / Spraying Type Fuse
-
Standard Hanging High-voltage Fuse
-
Isolation switch silicon rubber /33KV outdoor disconnect switches
-
Outdoor HV Disconnecting Switch
-
GWR isolating switch/ disconnect switch/ AC switch for high voltage
Popular Searches
- power transformer
- distribution service
- current transformer
- high frequency transformer
- electrical transformer
- energy saver device
- step up converter
- ac drive converter
- frequency drive converter
- lightning conductor
- copper lightning rod
- electronic transformer
- toroidal transformer
- auto transformer
- current transformer inductor
- voltage transformer
- control transformer
- power supply transformer
- led lighting transformer
- waterproof transformer
- electric transformer
- low frequency transformer
- flyback transformer
- core transformer
- output inductor
- power distribution equipment
- power distribution transformer
- transformer substation equipment
- oil immersed transformer
- filter reactor
Recommended Products
- JDS UNIPHASE 2214-308LQTC
- JDS UNIPHASE 2214-30SLQTA
- ICS Triplex T9451
- KOYO DL240CPU
- Honeywell FC-PDB-ARTF05
- Allen Bradley A5E32168144
- Allen Bradley 80190-580-01-R?
- Allen Bradley 80190-560-01-R
- Bently Nevada 84661-66
- Bently Nevada 330980-70-05
- Bently Nevada 330910-00-12-10-02-00
- Bently Nevada 330102-00-48-10-02-05
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Nancy Ni
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile