Home > Products > 9. AC Contactor > 23KW Capacitor Switching Contactor
23KW Capacitor Switching Contactor
- 200000 Piece / Pieces per Month
- Ningbo or Shanghai
- T/T L/C D/P D/A Credit Card PayPal
You May Like
-
400A 3POLE Electrical Contactor
-
25A 3POLE AC Magnetic Contactor (LC1)
-
12V 24V 48V dc to ac 110V 220V off grid 2000W/2KW modified sine wave solar home power inverter
-
12V /24V/ 48V dc to ac 110V /220V off grid 1500W/1.5KW, modified sine wave solar home power inverter
-
modified sine wave solar ,12V /24V/ 48V dc to ac 110V /220V off grid 3000W/3KW modified sine wave solar home power inverter
-
12V/ 24V /48V dc to ac 110V/ 220V off grid 500W modified sine wave, sloar home power inverter
Product Details
Place of Origin | Zhejiang, China | Brand Name | YOMIN | |
Model Number | CJ19-32 | Electricity Type | AC | |
Number of Pole | 3 | Phase | Other, Single-phase or Three-phase | |
Main Circuit Rating Voltage | Other, 24V, 36V, 110V, 220V, 380V, 415V |
Product Description
18Amps 23KW Capacitor Switching Contactor
Model: CJ19-32
Reversing Contactors (Magnetic Contactor) provide remote control of primarily electric motors and compensation & heating systems by cable. They protect the instruments and equipments against overload currents by using thermal relays, for capacitor switching contactor. While switching on a capacitive circuit, a high frequency (1...15Hz) and large transient current peaks are produced. Switching of capacitor for a single or one of the capacitor banks are different from each other. Step by step "switching on" operation is more difficult for contactor than capacitor bank. Because during this operation for capacitor bank, compensated current occurs. For this reason selecting of suitable contactors the compensating current must be take into consideration for 50kVAR and above, and for less than 50kVAR can be omitted.
- As it is known, when the capacitor starts to operate, they cause a high frequency between 1~15kHz. And a current that is 180time higher than rated current for very short time period. Shock inductance is to be fixed to each phase to limit this current. But practically this type of operation is difficult. That's why capacitor switching contactors are used and for this reason the life-time of contactors increase 100% in comparision with normal contactor.
- While Switching on a capacitive circuit, a high frequency (1...15kHz) and large transient current Peaks are produced. Switching of capacitor for a single or one of the capacitor banks are different from each other. Step by step "switching on" operation is more difficult for contactor than capacitor bank. Because during this operation for capacitor bank, compensated current occurs. For this reason selecting of a suitable contactors the compensating current must be take into consideration for 50kVAr and above, and for less than 50kVAr can be ommitted.
- Operating Principle: When coil of contactor is energized, first contact of passing block is closed, starting current of contactor is passed through this contact, approximately after 3-5 ms contacts of passing blocks are opened and rated current of contactor is carried on main contacts.
- Magnetic Contactor should have the high current value without being exposed to and damaged or boiling. This belongs to the quality of contactor. (Contact surface quality and weld technology) Especially at AC-3 and capacitor command, selectivity of contactor is very important.
- Current which passes through the contacts causes warming when the contactor is closed. This warming is limited with the standards. For IEC60947-4-1 when continual thermal current (Ith) is passed though the main contacts, maximum increasing temperature should not exceed 65k.
- While the contactor is cutting the current, electrical arc occurs between the seperated contacts. Arc is the result of the thermal impression of electron and ion current which broke off the contact material. Temperature of the arc reaches to thousands of degrees and this temperature is too high for metals and insulators which are used at contact making and cutting cells. Therefore, arc should end as soon as possible. For this reason separators are used inside of contactors.
- Rated Current.............................................................18A
- Control Capacity.........................................................23KW
- No. of Pole...................................................................3-POLE
- Rated Operational Voltage.........................................690V AC
- Rated Insulated Voltage.............................................690V AC
- Frequency....................................................................50/60Hz
- Standards................................................................... IEC60947-4-1
- IP / NEMA Rating.........................................................IP20
- Connection..................................................................Screw + Cable Lug
- Working Temperature................................................-20℃ ~ +80℃
- Mechanical Life.......................................................... 20,000times
- Sample Service...........................................................Pay to Provide
- Quality Assurance......................................................24 months
- Item Condition............................................................Brand-New
Item | Control Capacity | Rated Current | Case Qty. |
Model | (KW) | (A) | (Pcs.) |
CJ19-25 | 18 | 12 | 40 |
CJ19-32 | 23 | 18 | 32 |
CJ19-43 | 29 | 20 | 32 |
CJ19-63 | 43 | 30 | 20 |
CJ19-95 | 63 | 40 | 20 |
NB: Please mention the coil voltage when ordering. Our standard coil voltages are 24V, 36V, 110V, 220V, 380V, 415V, other else upon request.
Contact Us
- Yueqing Yomin Electric Co., Ltd.
- Contact nameLinda Chat Now
- Phone0086-577-61616259
- AddressQiaoqian Industrial Area, Liushi Town, Yueqing City, Wenzhou, Zhejiang
Product Categories
New Products
-
hot selling!!! 12V 24V 48V dc to ac 110V 220V off grid 300W modified sine wave solar home power inverter
-
12V /24V /48V dc to ac 110V/ 220V off grid 150W modified sine wave solar wave power inverter Quality Choice
-
12V /24V/ 48V dc to ac 110V 220V off grid 1000W/1KW modified sine wave solar home power inverter
-
127V 230V 3(16)A single phase electronic socket energy meter
-
Hot selling single phase three wire electronic round socket energy meter
-
NEW TYPE Single Phase Electronic Din Rail Active KWH Meter of LCD Display
-
NEW TYPE Single Phase Electronic Din Rail Active Power Meter of LCD Display Quality Choice
-
Hot selling!! single phase / three phase energy meter test bench /kwh meter test equipment/calibration test bench
-
NEW TYPE Single Phase Electronic Din Rail Active Electricity Meter of LCD Display
-
Industrial PG Molded Case Circuit-Breakers with Leakage Protection / 4P ELCB
-
Wholesale 2P / 4P PG Earth Leakage Residual Current Circuit Breaker RCCB
-
Single Phase Din Rail Active Types Of Electronic Window Type Lcd Display Watt Hour Digital Energy Meter Manufacturer
-
17.5mm width Single Phase Watt Hour Meter for Energy Monitor
-
Two Phase Three Wire Electric Energy Meter
-
Single phase KWH meter calibration test bench from China factory
-
Din-rail three phase Four Wire LCD Digital Prepaid Electric Meter
-
High Accuracy Single Phase Energy Meter test bench, Energy meter/
-
China Manufactory Single Phase Two Wire Electric Energy Meter, YEM313 Energy Meter/
-
High Accuracy Single Phase Energy Meter test bench, Energy meter Test bench/
-
Single phase KWH meter calibration test bench,China factory test bench/
-
CE ROHS approved 300W pure sine wave power inverter
-
Power Protector A/C Guard
-
Square Meter Box, 320R Series Meter Socket
-
YME1 Series Load Centers(Modular Enclosures)
Popular Searches
- ac contactor
- contactor
- Contactors
- magnetic contactor
- magnetic starter
- dc contactor
- Vacuum Contactor
- Electrical Contactor
- Magnetic Ac Contactor
- Modular Contactor
- Power Contactor
- Air Conditioner Contactor
- Relay Contactor
- Electric Contactor
- contact
- chint contactor
- Mini Contactor
- siemens contactor
- lc1
- telemecanique contactor
- ge contactor
- lighting contactor
- 220v single phase contactor
- contactor ac
- Ac Electric Contactor
- Amp Contactor
- ls contactor
- contact block
- contactor magnetic
- types of contactor
Recommended Products
- LS Metasol GMC-1260 AC/DC100-200V 2A2B
- LS Metasol GMC-800 AC/DC100-200V 2A2B
- LS Metasol GMC-600 AC/DC100-200V 2A2B
- LS Metasol GMC-400 AC/DC100-200V 2A2B
- LS Metasol GMC-300 AC/DC100-200V 2A2B
- LS Metasol GMC-100 AC/DC100-200V 2A2B
- LS Metasol GMC-125 AC/DC100-200V 2A2B
- LS Metasol GMC-150 AC/DC100-200V 2A2B
- LS Metasol GMC-180 AC/DC100-200V 2A2B
- LS Metasol GMC-220 AC/DC100-200V 2A2B
- LS Metasol DC48V Magnetic Contactor MC-40a
- LS Metasol DC220V Magnetic Contactor MC-100a
Find Similar Products By Category
- Electrical & Electronics > Relay & Contactor > Contactor
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Linda
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile