Home > Products > 5. LV Current Transformer > Good Quality 1200/5A Class 0.5 Split Core Current Transformer CT, Current Transformer/
Good Quality 1200/5A Class 0.5 Split Core Current Transformer CT, Current Transformer/
- 100000 Piece / Pieces per Month
- Ningbo or Shanghai
- T/T L/C D/P D/A Credit Card PayPal
You May Like
-
Manufacturer PVC taping MR-60 Current Transformer 500/5A, Cuttent Transformer/
-
Manufacturer 550VA Toroidal Transformer ,Power Audio Isolation Transformer .
-
Manufacturer 100VA Control Transformer ,With Terminal Blocks Transformer.
-
Manufacturer 150VA Control Transformer , RBK Series Copper Transformer .
-
Manufacturer 250VA Control Transformer ,BK Single Phase Transformer .
-
Manufacturer 1000VA Control Transformer (Foot Mounting) , Electricity Transformer .
Product Details
Place of Origin | Zhejiang, China | Brand Name | YOMIN | |
Model Number | DP-812-1200/5A | Usage | Current | |
Phase | Single | Coil Structure | Toroidal | |
Coil Number | Other, 240 |
Product Description
1200/5A Class 0.5 Split Core Current Transformer
Model: DP-812-1200/5A
Current Transformer (CT) is used to transform the high AC current to small easily manageable values. They're connected with the Panel Meter or Relay and they can help to measure the current or protect the equipments. Low voltage current transformers are manufactured as of two types for measuring CT.
- Measuring CT: Measuring current transformers are constructed to feed on other low voltage apparatus such as measuring instruments, relays, watt-hour meter (KW meter) and these type of current transformers are mainly used 0.5 and 1.0 class to transfer the current from highest rated current to rated secondary current.
- Protection CT: Protection current transformers are constructed to feed the protection relay. These type of current transformers are mainly used 5P. (Customer supplied when required.)
Split core current transformer has been specially designed to facilitate their installation in new or already existing net works. They may be installed without opening any cable or bus-bar circuit. The connection of conventional CTs usually requires the interruption of the primary side circuit to pass cables or bur-bars through the transformer core or to connect such cables to the primary terminals. The DBP series transformers core may be easily opened and they may be installed and connected without any supply interruption. Thus saving time and the installation costs.
- Two built in fixing methods:Base; Busbar mounting, very easy to mount the split core Current Transformer
- Split core design. Reliable and Safety, high accuracy.
- Wide inner window, allowing clamping of big cables or busbars.Wide range of sizes to accommodate all the existing installations.
- Primary current from 5A to 5000A.
- Accuracy class up to 0.5.
- Provide lead seal hole to seal the secondary terminal cover to prevent electricity stealing.
Selection of the Current Transformer
To select the current transformer correctly, the following points should be clarified:
- -The application (for measuring or protection).
- -The features of the working environment (Indoor or outdoor, operating temperature, air humidity etc….).
- -Operation voltage and frequency.
- -Range of the primary current (maximum and minimum of the current to be measured).
- -Dimension of the cable or Bus bar.
- -Data of the overload.
- -Short circuit current.
- -Specification of the measuring device associated with the current transformer (Accuracy, rated current, consumption etc…).
- -The diameter and length of the cable, the cable which is used to connect the current transformer and associated measuring device.
Power Losses of the CT
In the practical application, the power generated by the primary current should be equal or bigger than the power requirement of the associated measuring device plus the consumption of the connecting line.
Losses in the line, PL:
This is the power loss, through heat, generated by current through the resistance RL in the cable, in the transformer’s secondary circuit.
Factors to be taken into account:
Secondary current: PL = RL / 2
Cable diameter: RL is inversely proportional to the square of the diameter cable length: RL is proportional to the length of cabling (there and back).
Power: The nominal apparent power (VA) with a specified power factor, which was supplied by the Current Transformer, to the secondary current with the assigned current when it is connected to its nominal load. Sc (VA) = Zc (/sn)2 According to Standards, for apparent power greater than or equal to 5VA, the power factor is 0.8 inductive. For apparent power less than 5VA the power factor is considered to be one (unity).
Accuracy of A Current Transformer
The percentage of error, produced in a transformer, is established by IEC60044-1. In measurement transformer: 25% and 100% of nominal power. In protection transformers: 100% of nominal power.
Note: with…/1A transformers losses are reduced 25 times.
Saturated Condition of CT
The current transformer is saturated if the primary current, passing through the CT, is greater than the nominal rating of the CT.
The linearity of CT, between the primary and secondary sides decreases, so error increases. The saturation of the CT is inversely proportional to the load (FIG. 1).
The difference between measuring and protection current transformers is their behavior when an overload occurs on the primary side. Measuring CT is saturated when there is a primary current overload. In order to protect the equipment. On the secondary side, protection CT will not saturated until there is a very high current on the primary side, A class 5P15 protection transformer indicates that it has an accuracy rating of ±1% that it does not become saturated until the primary current reaches 15 times the nominal current rating of the CT.
In measuring transformers, the SAFETY FACTOR “FS” parameter indicates the excessive amperage on the primary side current in relation to the current sent to the measuring device on the secondary side.
Application Note
If the primary current is too small, to keep the same accuracy and output, we can add primary winding, but the rated turns ration should be the same, For example, if the primary current is 50A, we can use 100/5A current transformer with the primary current be turned twice which help to keep the same rated turns ratio (1:50 = 2:100).
Construction
CT consist of primary winding, secondary winding, magnetic core and insulated body. The high-grade silicon steel core is annealed, varnished then insulated with polycarbonate core caps. The secondary winding is toroidally wound by high precision semi-automatic machinery. For the tape wound ring type current transformer, the PEW coated windings are then covered with elephantite paper, varnished and double-tapped with PVS tapes. For the encapsulated type current transformer, the windings are enclosed in a compact and heat resistant split cap.
- Current Ratio..................................................................................1200/5A
- Accuracy.........................................................................................Class 0.5
- Burden.............................................................................................See Selection Form.
- Security Factor................................................................................FS<5
- Max System Voltage.......................................................................720V AC
- Test Voltage.....................................................................................3kV AC. (1 min.)
- Frequency........................................................................................50/60Hz
- Rated Short-time Thermal Current (Ith)........................................Ith = 60 X In
- Rated Dynamic Current (Idyn).......................................................Idyn = 2.5 X Ith
- Continuous Overload.....................................................................1.2 X In
- Working Temperature....................................................................-25°C ~ +50°C
- insulation Rating.............................................................................Class B
- Housing Self-extinguishing Class.................................................VO.
- Bus-bar Support Mounting.............................................................Provided.
- Panel Mounting................................................................................Provided.
- Hinged Sealable Terminal Cover....................................................No Provided.
- Standards.........................................................................................IEC/EN60044-1, VDE0414-44-1, BS3938, BS7626
- Item Condition..................................................................................Brand New.
- Quality Assurance...........................................................................24 Months.
- Sample Service................................................................................Provided.
Item | Current Ratio | Rated Burden (VA) | Case Qty. | |
Model | (A) | Class: 0.5 | Class: 1.0 | (Pcs) |
DP-812 | 500/5 | - | 2.5 | 10 |
600/5 | - | 2.5 | 10 | |
750/5 | 2.5 | 5 | 10 | |
800/5 | 2.5 | 5 | 10 | |
1000/5 | 3.75 | 7.5 | 10 | |
1200/5 | 5 | 10 | 10 | |
1250/5 | 5 | 10 | 10 | |
1500/5 | 7.5 | 10 | 10 |
Note:
Class and VA rating must be mentioned when ordering.
Model | A | B | C | D | E | F | G | H | I |
DP-23 | 20 | 30 | 51 | 89 | 111 | 34 | 47 | 40 | 32 |
DP-58 | 50 | 80 | 78 | 114 | 145 | 32 | 32 | 32 | 33 |
DP-88 | 80 | 80 | 108 | 144 | 145 | 32 | 32 | 32 | 33 |
DP-812 | 80 | 120 | 108 | 144 | 185 | 32 | 32 | 32 | 33 |
DP-816 | 80 | 120 | 120 | 184 | 245 | 52 | 47 | 52 | 38 |
Contact Us
- Yueqing Yomin Electric Co., Ltd.
- Contact nameLinda Chat Now
- Phone0086-577-61616259
- AddressQiaoqian Village, Liushi Town, Yueqing
Product Categories
New Products
-
Manufacturer 400VA Machine Tool Control Transformer,Isolation Transformer Quality Choice
-
Manufacturer BK Series 220 V 24V Machine Tool Transformer, Control Power Transformer Capacity100VA Quality Choice
-
Manufacturer BK Series Control Transformer , Single Phase Isolation Transformer 40VA . Quality Choice
-
Manufacturer 120VA International Typical Transformer , Isolation Transformer .
-
Manufacturer 25VA International Typical Transformer , Single Phase Transformer / Quality Choice
-
Manufacturer 50VA International Typical Transformer , Single Phase Transformer .
-
Manufacturer 63VA International Typical Transformer , Isolation Transformer.
-
Manufacturer 40VA International Typical Transformer , Single Phase Transformer .
-
Manufacturer 100VA International Typical Transformer , Power Transformer
-
Manufacturer 30VA International Typical Transformer , Isolation Transformer .
-
Manufacturer 6.3VA International Typical Transformer, Single Phase Transformer /
-
Manufacturer Hot Sale 20VA International Typical Transformer , Electrical Transformer . Quality Choice
-
Manufacturer 2VA International Typical Transformer,Single Phase Transformer /
-
Manufacturer 3VA International Typical Transformer ,Single Phase Transformer .
-
Manufacturer 60VA Control Transformer ,Isolation Power Transformer .
-
Manufacturer 630VA Control Transformer ,Electrical Transformer .
-
Manufacturer 1.6VA International Typical Transformer, E type Electric Transformer
-
Manufacturer 500VA International Typical Transformer Metallic Quality Choice
-
Manufacturer 300VA International Typical Transformer ,Electrical Transformers
-
Manufacturer 250VA International Typical Transformer ,Single Phase Transformer .
-
Manufacturer 200VA International Typical Transformer ,Power Transformer .
-
Manufacturer 160VA International Typical Transformer , Isolation Transformer .
-
Manufacturer 80VA International Typical Transformer , Single Phase Transformer .
-
Manufacturer Single Phase Isolated 12VA Transformer,International Typical Transformer
Popular Searches
- power transformer
- Distribution Service
- current transformer
- power transformers
- High Frequency Transformer
- Electrical Transformer
- energy saver device
- led transformers
- step up converter
- Ac Drive Converter
- Frequency Drive Converter
- lightning conductor
- Copper Lightning Rod
- electronic transformer
- Lighting Transformers
- toroidal transformer
- auto transformer
- current transformer inductor
- voltage transformer
- Control Transformer
- Power Supply Transformer
- Led Lighting Transformer
- Waterproof Transformer
- Electric Transformer
- Low Frequency Transformer
- Flyback Transformer
- Core Transformer
- pot & kettle
- Output Inductor
- Power Distribution Equipment
Recommended Products
- BENTLY NEVADA 330704-000-026-50-01-CN
- BENTLY NEVADA 330703-000-026-10-01-CN
- SIEMENS 6SL3210-1KE11-8AF2
- SIEMENS 6S13040-1MA00-0AA0
- SIEMENS 6SN1145-1BA01-0BA2
- SIEMENS 6SL3224-0BE33-7UA0
- SIEMENS 6SL3544-0FB20-1FA0
- SIEMENS 66SL3544-0FA20-1PA0
- SIEMENS 6SL3525-0DE24-0AA1
- Siemens 16137-174
- SIEMENS 6SN1145-1BA02-0CA2
- SIEMENS 6SL3120-2TE13-0AA4
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Linda
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile