Home > Products > Magnetic Flowmeter > Electromagnetic Flow meter(CE Approved)
Electromagnetic Flow meter(CE Approved)
- 500 Set / Sets per Month
- Shanghai
You May Like
Product Details
Place of Origin | Shanghai, China | Brand Name | SHHUGE | |
Model Number | AM200/300 |
Product Description
Specifications
Electromagnetic Flow meter(CE Approved)1>Bi-direction measuring and totalizing
2>High accuracy,0.5%
3>have RS232 RS485
AM200/300 Electromagnetic Flow meter(CE Approved) is the advanced engineering designed magnetic flowmeter, It has a dual cavity housing providing ease of wiring while isolating the electronics from the environment. AM200/300 continues the use of low frequency excitation, which provides noise free output. AM200/300 excitation method and multiform lining allow this magnetic flowmeter to be applied to an even greater range of applications
FEATURES
- Fast response and high stability.
- High Accuracy, 0.5% of flowrate.
- Dual cavity housing to separate electronics part from wiring part.
- AC power supply common use (80/264V).
- High visible backlit LCD for easy operation.
- With multiform communication e.g. RS485,RS232C,HART,Pfofibus,MODBUS etc.
- Bi-direction measuring and totalizing
STANDARD SPECIFICATIONS
I;Converter
Measuring Range
The velocity range is 0.3m/s to 15m/s. The minimum measurable speed can be one percent (1%) of the full range.
Accuracy
DN (mm) | Velocity m/s | Accuracy |
25 ~ 1200 | 0.1~0.3 | ±0.25%FS |
0.3~1 | ±0.5%R | |
1~15 | ±0.3%R | |
%FS:Relative range;%R:Relative measured |
Analog Output
Current output: fully-isolated 0 - 10mA / 4 - 20mA
Load resistance: 0 to 1.5kΩ at 0 - 10mA; 0 to 750Ω at 4 - 20mA
Base error: add ±10μA on top of the measurement error
Frequency Output
Frequency output is proportional to the flow percentage of the full range. It provides fully isolated transistor open collector frequency output ranged from 1 to 5000 Hz. The external DC power supply should not exceed 35V and maximum collector current is 250mA.
Pulse Output
The converter can output up to 5000cp/s pulse series, which is dedicated to external totalization. Pulse factor is defined as pulse count per unit volume or mass. It can be set to 0001-9999p/L, 0001-9999p/m3, 0001~9999p/kg or 0001~9999p/t. Pulse width is selectable from 16ms, 33 ms, 66mm, 99ms or auto square wave. Photo-coupler isolated transistor open collector circuit is used for pulse output. The external DC power supply should not exceed 35V and maximum collector current is 250mA.
Showing Flow Direction & Range
The converter is capable of measuring both forward and reverse flow and recognizing its direction. The converter outputs 0V low level for forward flow, while +12V high level for reverse flow.
Alarm Out
Two channels of photo-coupler isolated open collector circuit are used for alarm signal output. There are two alarm outputs: high limit alarm and low limit alarm. The external DC power supply should not exceed 35V and maximum collector current is 250mA.
Communication
The RS485, RS232C, HART, Profibus, MODBUS communication interface are embedded in the converter. Surge absorber is optional to protect the interface and converter.
Damping Constant
Damping time is optional from 0.2 to 100s
Input Contact
External contact ON (close) or OFF (open) signal can be used to remotely control the start/stop or reset of internal counter.
Display Function
Flow rate can be displayed either in engineering units or in percent of span. Totalized volume in any engineering unit can be displayed by setting a totalizing factor.
Self Diagnostics Function
Converter failure, flow tube failure, erroneous setting, etc. can be diagnosed and displayed.
Data Security During Power Failure
Data storage by EEPROM - no back-up battery required
Electrical Connection
ISO M20´1.5 female
Terminal Connection
M4 size screw terminal
Case Material
Aluminum alloy
Coating
Polyurethane corrosion-resistant coating. Cover; Deep sea moss green (Munsell 0.6GY3.1/2.0) Case; Frosty white (Munsell 2.5Y8.4/1.2)
Protection
IP67, NEMA4X
12 inch electromagnetic flowmeter
2 " rubber in the village of electromagnetic flowmeter
2 " PTFE, electromagnetic flowmeter
II;Magnetic Flow Tube
Nominal Diameter
Lining | Rubber | PTFE | PFA |
DN (mm) | 25,32,40,50,65,80,100 125,150,200 250,300,350 400,450,500,600,700,800,900 1000,1200 | 25,32,40,50 65,80,100 125,150,200 250,300,350 400 | 25,32,40 50 65,80,100 |
Flow Tube Material
Size 25 to 100 mm
- Housing: Stainless steel (SUS304)
- Flange: Stainless steel (SUS304)
- Pipe: Stainless steel (SUS304)
Size 150 to 1200 mm
- Housing: Carbon steel (SPCC)
- Flange: Carbon steel (SS400)
- Pipe: Stainless steel (SUS304)
Wetted Part Material
- Lining: Rubber, PTFE or PFA
- Electrode: Stainless steel (SUS316L), Hastelloy C,Titanium,Tantalum, Platinum
- Earth Ring/Earth Electrode: Stainless steel (SUS316)
NORMAL OPERATING CONDITIONS
- Ambient Temperature: -20 to 60°C
- Ambient Humidity: 5 to 95%RH
- Power Supply Voltage: 80 to 264 V AC
- Fluid Conductivity:20mS/cm or larger
MODEL AND SUFFIX CODE
Dedicated Signal Cable
Model | Suffix Code | Description |
AM011 | …………………. | flowmeter |
End treatment | -0…………….. -1……………… | Non termination Terminated |
Cable length | -L………. | Enter the length in m (Max 30m) |
Contact Us
- Shanghai Huge Automation Instrumentation Co., Ltd.
- Contact namefayuan dai Chat Now
- Phone86-21-39804116
- AddressBuilding 1-5, No. 103, Jinchang, Jinxiang Village, Baihe Town
Product Categories
Liquid Flow meter | Magnetic Flowmeter | New Products | Rotor |
Turbine | Vortex |
New Products
-
Magnetic flow meter
-
Magnetic flow meter
-
Magnetic flow meter
-
Magentic flow meter
-
Magentic flowmeter
-
Magentic flow meter
-
Electromagnetic Flowmeter(CE Approved)
-
Electromagnetic Flow meter
-
Electromagnetis water flow meter
-
Electormagnetis flow meter
-
Electromagnetic Flow meter(CE Approved)
-
Magnetisch-induktiver Durchflussmesser
Popular Searches
- air flow meter
- Hour Meter
- Digital Clamp Meter
- temperature meter
- Meter Counter
- Energy Meter
- Clamp Meter
- Frequency Meters
- Clamp Meters
- flow meter
- air flowmeter
- Ultrasonic Flow Meter
- Water Flow Meter
- Turbine Flow Meter
- Sewage Flow Meter
- Vortex Flow Meter
- Ac Clamp Meter
- Magnetic Flow Meter
- alcohol meter
- correction liquid
- Energy Meters
- Flow Measuring Instruments
- water flowmeter
- flow sensor water
- liquid control meter
- oil flow meter
- flow measurement
- water flow rate meter
- flow indicator
- liquid flowmeter
Recommended Products
- Alicat MWB Low Pressure Loss Series Portable Series Gas Mass Flow Meter
- Alicat MB Series Portable Series Gas Mass Flow Meter
- Alicat Standard M-Series Gas Mass Flow Meter
- Alicat MC Standard Series Gas Mass Flow Controller
- Ufm/universal flow monitors flow switch MN-DSF300LM-16-1050
- Siemens 840D Handwheel 6FX2007-1AC04/1AE14/1AC14/1AC04 CNC Pendant Unit Currently
- Siemens7ML1998-5NE11/MANUAL, SITRANS LUT400 COMMUNICATIONS, FRENCH
- 7ML1998-5NE01/MANUAL, SITRANS LUT400 COMMUNICATIONS, ENGLISH
- 7ML5740-2AA11-0A/Universal input, panel-mounted digital display. RD200, power supply 12-36 V DC, MODBUS.
- 7ML5740-2AC01-1A/ IS A UNIVERSAL INPUT, PANEL MOUNT REMOTE DIGITAL DISPLAY FOR PROCESS INSTRUMENTATION. RD200 12-36 VDC DISPLAY WITH 4-20,2X
- 7ML5811-1A/up to 20 relay outputs, switchable AC/DC power supply, certifications CSA NRTL/C, FM, CE.
- 7ML5740-2AC01-1A/THE SITRANS RD200 IS A UNIVERSAL INPUT, PANEL MOUNT REMOTE DIGITAL DISPLAY FOR PROCESS INSTRUMENTATION. RD200 12-36 VDC DISPLAY
Find Similar Products By Category
- Instruments & Meters > Meter for Liquid & Gas > Flow Meter
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
fayuan dai
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile