Place of Origin | Jiangsu, China | Brand Name | NON | |
Model Number | E40 |
Product Description
Temperature Controller
Main Function
Temperature display, temperature controlling(refrigeration/heat mode),compressor start delay protection, it can run periodically with the on-off rate when the temperature sensor is broken. 2 defrost modes (electric heat, hot gas), 3 defrost start mode (time alternation, accumulative compressor running time, real time clock), 2 defrost end mode (timing, controlled by both temperature and time), dripping, manual defrost, 7 fan running modes(fan ahead or delay start, delay stop, temperature controlling start and stop, time controlling start and stop, always on, always off, run or stop when defrosting), high and low temperature alarm, sensor error alarm, one external alarm input, password, real time clock, C/F unit change.
Technique Index
1.Temperature display range: -50~150°C(The resolution is 0.1°C)
-58~302°F(The resolution is 0.1F)
2.Power supply: AC 220V±10% or AC 380V±10% 50Hz (Refer to the wiring diagram)
3.Operating environment: temperature -30°C~80°C, humidity≤85%
4.Relay contact capability: 8A/250VAC (pure resistive load)
5.Temperature sensor: NTC R25=5kΩ, B (25/50) =3470K
Operating Guide
1, Meaning of the index lights on the panel
Index light | Name | Light | Flash |
| Temp setting | In the state of temp setting | - |
| Refrigeration | Refrigerating | Ready to refrigerate, in the state of compressor start delay protection |
| Heat | Heating | Ready to heat, in the state of compressor start delay protection |
| Defrost | Defrosting | Dripping or the state of compressor start delay protection |
| Fan | Fan running | - |
| Alarm | - | Alarm state |
2,Meaning of the LED display
The LED usually shows temperature, if it shows “SHr”, it means the temperature sensor is short, and “OPE” means the temperature sensor is open. The temperature and the alarm code (Axx) will show alternately when in the alarm state. The code is showing below:
Code | Meaning | Explanation |
A11 | External alarm | Alarm from external alarm signal, refer to the internal parameter code “F50” |
A21 | Temperature sensor error | Open or short(showing “OPE” or “SHr”) |
A22 | Evaporator sensor error | Open or short(showing “OPE” or “SHr” when press the key “6”). If you don’t need to use the evaporator sensor, you can use the F59 to close the alarm. |
A31 | High temp alarm |
|
A32 | Low temp alarm |
|
A99 | Over probation time | If you have set the probation time F87, the alarm occurs when the accumulative running time is over probation time, and the controller can not work. |
Contact Us
- Suzhou Chuangtai Electronics Co., Ltd.
- Contact nameAndy Ting Chat Now
- Phone86-512-53111981
- Address(Donggang Village) Chengqu Industrial Park, Chengxiang Town, Suzhou, Jiangsu
Product Categories
Infrared Thermometer | New Products | NTC Senor | Protector |
Tempaerature Controller | Temperature controller | Temperature&Humidity Recorder | Water Heater Controller |
New Products
-
Digitai Temperature Controller
-
Temperature Controller
-
Temperature Controller
-
Digital Temperature Controller
-
Digital Temperature Controller
-
Temperature Controller
-
Digital Temperature control
-
Digital Temperature Controller
-
Reliable digital mitemperature controller
-
D20 temperature controll
-
B10 Microcomputer temperature controller
-
B20 Digital temperature controller
Popular Searches
- Level Sensor
- temperature indicator
- Radar Level Meter
- Water Level Meter
- density sensor
- temperature sensor
- water level switch
- Float Switch
- Level Gauge
- Level Indicator Sensor
- level measuring instrument
- Level Measuring Instruments
- level transmitter
- level indicator
- level meter
- level transducer
- Level Gauge Instrument
- Level Transmitter Instrument
- Water Level Sensor
- Level Switch
- pressure indicator
- Level Pressure Transmitter
- Paddle Switch
- Fuel Level Sensor
- temperature switch
- water switch
- explosion proof level switch
- explosion proof float switch
- Meter Tuning Fork
- frequency indicator
Recommended Products
- Magnetic Flapper Roller Flipper Display Panel Scale Profile Gauge Parts Ceramic High Temperature Flip Spare Components
- SUS 304 Magnetic Level Gauge Flapper Roller Flapper Display Panel Scale Profile PVC Plastic Flag Level Sensor Parts Stainless
- Ultrasonic level gauge KYU800
- Endress+Hauser Ultrasonic level transmitters
- Endress+Hauser Guided radar level transmitters
- Endress+Hauser Radar level transmitters
- Endress+Hauser Level transmitters
- Precision sound level meter DB30-6228N
- Pulse sound level meter DB30-6226I
- Pulse Impulse Sound Level Meter DB30-6228ILEQ
- Customized 244LD Displacer Level Transmitter Useing FOXBORO 244LD LevelStar Head
- Customized Displacer Level Transmitter Useing Fisher DLC3010 Digital Level Controller As Torque Tube
Find Similar Products By Category
- Instruments & Meters > Meter for Liquid & Gas > Liquid Level Meter
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andy Ting
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile