Home > Products > Francis turbine > 1000KW hydraulic generator for hydro power station
1000KW hydraulic generator for hydro power station
- Shanghai
- T/T
You May Like
Product Details
Place of Origin | Sichuan, China | Brand Name | WAWUSHAN | |
Model Number | HL-007 | Type | Other, hydraulic power |
Product Description
1000KW hydraulic generator for hydro power station
Reaction turbines
Reaction turbines are acted on by water, which changes pressure as it moves through the turbine and gives up its energy. They must be encased to contain the water pressure (or suction), or they must be fully submerged in the water flow.
Newton's third law describes the transfer of energy for reaction turbines.
Most water turbines in use are reaction turbines and are used in low (<30m/98 ft) and medium (30-300m/98–984 ft) head applications. In reaction turbine pressure drop occurs in both fixed and moving blades.
Impulse turbines
Impulse turbines change the velocity of a water jet. The jet pushes on the turbine's curved blades which changes the direction of the flow. The resulting change in momentum (impulse) causes a force on the turbine blades. Since the turbine is spinning, the force acts through a distance (work) and the diverted water flow is left with diminished energy.
Prior to hitting the turbine blades, the water's pressure (potential energy) is converted to kinetic energy by a nozzle and focused on the turbine. No pressure change occurs at the turbine blades, and the turbine doesn't require a housing for operation.
Newton's second law describes the transfer of energy for impulse turbines.
Impulse turbines are often used in very high (>300m/984 ft) head applications .
Design and application
Turbine selection is based mostly on the available water head, and less so on the available flow rate. In general, impulse turbines are used for high head sites, and reaction turbines are used for low head sites. Kaplan turbines with adjustable blade pitch are well-adapted to wide ranges of flow or head conditions, since their peak efficiency can be achieved over a wide range of flow conditions.
Small turbines (mostly under 10 MW) may have horizontal shafts, and even fairly large bulb-type turbines up to 100 MW or so may be horizontal. Very large Francis and Kaplan machines usually have vertical shafts because this makes best use of the available head, and makes installation of a generator more economical. Pelton wheels may be either vertical or horizontal shaft machines because the size of the machine is so much less than the available head. Some impulse turbines use multiple water jets per runner to increase specific speed and balance shaft thrust.
Typical range of heads
• Hydraulic wheel turbine | 0.2 < H < 4 (H = head in m) |
how to calcualte power
P=N*P*G*H*Q
where:
- P=power (J/s or watts)
- N=turbine efficiency
- P= density of water (kg/m³)
- G= acceleration of gravity (9.81 m/s²)
- H= head (m). For still water, this is the difference in height between the inlet and outlet surfaces. Moving water has an additional component added to account for the kinetic energy of the flow. The total head equals the pressure head plus velocity head.
- Q= flow rate (m³/s)
Contact Us
- Hongya Power Generating Equipment To Utilities Limited
- Contact namejack shen Chat Now
- Phone86-28-13219745153
- AddressYuping Town, Meishan, Sichuan
Product Categories
Francis turbine | hydro generator | kaplan turbine | New Products |
Pelton turbine | power plant |
New Products
-
Francis turbine generator hydro power plant Kaplan pelton Francis generator
-
micro hydro turbine for hydro power plant
-
Micro Francis turbine generator for hydro power plant
-
water turbine generator for hydro power plant
-
water turbine generator kaplan pelton francis water turbine generator
-
water turbine generator francis kaplan pelton water turbine generator
-
water power generator
-
water power generator for power plant
-
hydroelectric generator for power plant
-
water turbine generator for power plant
-
water turbine generator for power plant francis water turbine generator
-
micro water turbine generator for power plant
Popular Searches
- Alternative Energy Generators
- wind generator
- Permanent Magnet Generator
- Wind Turbine Generator
- Vertical Wind Turbine Generator
- Wind Power Generator
- Water Turbine Generator
- Horizontal Wind Generator
- turbine
- alternative energy
- hydro turbine generator
- windmill generator
- Turbine Power Generator
- Turbine Generator Set
- Permanent Magnet Alternator
- wind turbine
- wind power
- turbine generator
- low rpm generator alternator
- Energy Generator
- free energy permanent magnet generator
- free energy magnet generator
- magnet generator
- hydro turbine
- Neodymium Magnet Generator
- Horizontal Engine
- steam turbine
- hydro power
- pmg
- alternative energy generator
Recommended Products
- Hydraulic Disc Brake
- Wind Power Using Duplex Stainless Steel PSA Fall Protection Anchor
- 20KW MOBILE DC charging pile User Manual for Car Charging Station
- 40KW MOBILE DC charging pile User Manual for Car Charging Station
- Hydraulic Lockpin for wind turbine
- 120KW DC fast EV charger with two connectors for Car Charging Station
- 120KW DC fast EV charger with two connectors for Car Charging Station
- Fast electric car charging station ev charger pile DC 40kw 5m cable 1 MOQ to deliver in stock
- Full Automatic Solar Panel Production Line Equipment
- 500MW Solar Panel Production Line Equipment
- 450MW Solar Panel Production Assembly Line Equipment
- Full Automatic Solar Module Production Line Equipment
Find Similar Products By Category
- Industrial Equipment & Components > Power & Generating Sets > Wind Generator
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
jack shen
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile