Place of Origin | Taiwan, China | Brand Name | TES | |
Model Number | PROVA803 | Measuring Current Range | 0-20A | |
Measuring Voltage Range | 0-9999 | Measuring Resistance Range | 2 -200M | |
Measuring Capacitance Range | 9999uF | Measuring Inductance Range | 0----1999H | |
Operating Temperature | -40 to 1372℃ | Dimensions | 193mm(L)X91mm(W)X53mm(H) |
Product Description
Specifications:
The following accuracy is specified for one single channel (channel 1 or channel 2). If dual channels are used at the same time, additional % of accuracy should be added to the listed accuracy. Please refer to the supplemental dual channels specification. The following accuracy is also specified for the ZEROED (relative) value. The accuracy is given as ±% of reading ± number of least significant digits.
Continuity :(open voltage 3V approx.)
Range | Resolution | Beeper | Overload Protection |
999.99 Ω | 0.01 Ω | < 40 Ω ( approx ) | AC 1000V |
Frequency : (TTL) (Overload Protection AC 1000V)
Range ( Auto ) | Resolution | Accuracy |
1.000Hz - 2MHz | 0.0001Hz - 0.0001MHz | ±0.005%±4dgts |
DC Voltage: (Input Impedance: 10MΩ )(Overload Protection DC 1000V)
Range | Resolution | Accuracy |
60.000mV | 0.001mV | ±0.2%±9dgts |
600.00mV | 0.01mV | ±0.04%±6dgts |
6.0000V | 0.0001V | ±0.04%±6dgts |
60.000V | 0.001V | ±0.04%±6dgts |
600.00V | 0.01V | ±0.04%±6dgts |
1000.0V | 0.1V | ±0.08%±6dgts |
DC Current: (10A terminal is protected by a 20A fast blown, high energy fuse, and the terminal of μ A and mA is protected by 1A fast blown, high energy fuse )
Range | Resolution | Accuracy |
600.00μA | 0.01μA | ±0.4%±20dgts |
6000.0μA | 0.1μA | ±0.2%±20dgts |
60.000mA | 0.001mA | ±0.4%±20dgts |
600.00mA | 0.01mA | ±0.2%±20dgts |
1.0000A | 0.0001A | ±0.2%±20dgts |
10.000A 1 | 0.001A | ±0.6%±20dgts |
Diode Test: (open voltage 3V approx. overload protection AC 1000V)
Range | Resolution | Accuracy | Short Circuit Current |
3.0000V | 0.0001V | ±2%±5dgts | 0.8 mA typical |
Duty Cycle: (%, TTL, 1Hz – 600KHz) (Overload Protection AC 1000V)
Range | Resolution | Accuracy |
0.001% - 9.999% | 0.001% | ±30d/KHz±30dgts |
10.00% - 100.00% | 0.01% | ±3d/KHz±3dgts |
Resistance: ( Ω )
Range | Resolution | Accuracy | Overload Protection |
999.99 Ω | 0.01 Ω | ±0.25%±9dgts | AC 1000V |
9.9999K Ω | 0.0001K Ω | ±0.15%±6dgts | AC 1000V |
99.999K Ω | 0.001K Ω | ±0.15%±6dgts | AC 1000V |
999.99K Ω | 0.01K Ω | ±0.15%±6dgts | AC 1000V |
9.9999M Ω | 0.0001M Ω | ±0.3%±9dgts | AC 1000V |
40.000M Ω | 0.001M Ω | ±1.5%±9dgts | AC 1000V |
Capacitance: (auto range , and for film capacitor or better)
Range | Resolution | Accuracy 1 |
60.00nF | 0.01nF | ±1.2% ± 8dgts |
600.0nF | 0.1n F | ±2.5% ± 8dgts |
6.000 μ F | 0.001 μ F | ±2.5% ± 8dgts |
60.00 μ F | 0.01 μ F | ±3.0% ± 8dgts |
600.0 μ F | 0.1 μ F | ±5.0% ± 8dgts |
AC Voltage: The accuracy of ACV or AC mV is specified for 5%-100% of range from 20Hz-10KHz, average sensing.Input Impedance is 10M Ω , and overloaded protection is AC 1000V for all range. Accuracy is also specified for single channel (channel 1 or channel 2). If dual channels measurements are performed, additional specification of accuracy will be introduced. Please refer to the supplemental dual channels specification. Due to the wide bandwidth, the reading might not be zero when no inputs present. But the residual reading does not affect the listed accuracy. If the AC reading is less than 100 least significant counts, it is set to zero by the un it.
Range (ACV) | Resolution | Accuracy (50/60Hz) | Accuracy (45Hz-1KHz) | Accuracy (20Hz-45Hz) | Accuracy (1KHz-10KHz) |
60.000mV | 0.001mV | ±0.2%±40dgts | ±0.6%±40dgts | ±1.6%±50dgts | ±4% 40dgts |
600.00mV | 0.001mV | ±0.2%±40dgts | ±0.6%±40dgts | ±1.6%±50dgts | ±2%±40dgts |
6.0000V | 0.01mV | ±0.2%±40dgts | ±0.6%±40dgts | ±1.6%±50dgts | ±2%±40dgts |
60.000V | 0.0001V | ±0.2%±40dgts | ±0.6±40dgts | ±1.6%±50dgts | ±2%±40dgts |
600.00V (0-400V) | 0.001V | ±0.2%±40dgts | ±1.0%±40dgts | ±1.6%±50dgts | ±9%±40dgts |
600.00V (400-600V) | 0.01V | ±0.2%±40dgts | ±1.0%±40dgts | ±1.6%±50dgts | Not Specified |
1000.0V (0-400V) | 0.1V | ±0.2%±40dgts | ±4%±60dgts | ±1.6%±50dgts | ±4%±80dgts |
1000.0V (400-1000V) | 0.1V | ±0.2%±40dgts | (45Hz-400Hz) ±4%±60dgts | ±1.6%±50dgts | Not Specified |
Supplemental Dual Channels Specification (DC -400Hz): The following accuracy should be added to all the listed accuracy if dual channels measurements are performed.
ACV (Ch2) | DCV (Ch2) | ACA (Ch2) | DCA (Ch2) | |
ACV (Ch1) | ±2%±(V1-V2)* 200 PPM (Ch1,Ch2) | ±0.9%±(V1-V2)* 20PPM (Ch1,Ch2) | ±0.2μA/V(μA,Ch2) | ±0.5% (Ch1, Ch2) |
DCV (Ch1) | ±0.9%±(V1-V2)*20 PPM (Ch1,Ch2) | ±0.5% (Ch1,Ch2) | ±0.5% (Ch1,Ch2) | ±0.5% (Ch1,Ch2) |
AC Current: (The accuracy is specified for a single channel for 5%-100% of range for 45Hz–10KHz,average sensing, 10A terminal is protected by a 20A fast blown, high energy fuse, and the terminal of μ A and mA is protected by 1A fast blown, high energy fuse. If the AC reading is less than 100 least significant digits, it is set to zero by the unit )
Range (ACA) | Resolution | Accuracy (50/60Hz) | Accuracy(45Hz-1KHz) | Accuracy (20Hz-45Hz) | Accuracy (1KHz-10KHz) |
600.00μA | 0.01mA | ±0.6%±40dgts | ±0.8%±40dgts | ±2%±20dgts | ±4%±20dgts |
6000.0μA | 0.1mA | ±0.6%±40dgts | ±0.8%±40dgts | ±2%±20dgts | ±4%±20dgts |
60.000mA | 0.001mA | ±0.6%±40dgts | ±0.8%±40dgts | ±2%±20dgts | ±0.9%±20dgts |
600.00mA | 0.01mA | ±0.6%±40dgts | ±0.8%±40dgts | ±2%±20dgts | ±0.9%±20dgts |
1.0000A | 0.0001A | ±0.6%±40dgts | ±0.8%±40dgts | ±2%±20dgts | ±2.5%20dgts |
10.000A 1 | 0.001A | ±0.9%±40dgts | ±0.9%±40dgts | ±3.9%±20dgts | ±2.5%20dgts |
Range | Accuracy | Accuracy | Accuracy |
600.00μA | ±1%±20dgts | ±2%±20dgts | ±1%±20dgts |
6000.0μA | ±1%±20dgts | ±2%±20dgts | ±1%±20dgts |
60.000mA | ±1%±20dgts | ±0.5%±20dgts | ±1%±20dgts |
600.00mA | ±1%±20dgts | ±0.5%±20dgts | ±1%±20dgts |
1.0000A | ±1%±20dgts | ±1.5%±20dgts | Not Specified |
10.000A 1 | ±2%±20dgts | ±1.5%±20dgts | Not Specified |
General Specification:
Battery Type: | 9V |
Display: | 5 + 5 digits LCD with 30 segments bar graph |
Range Selection: | auto and manual |
Overload Indication: | OL |
Power Consumption: | 4 mA (approx) |
Low battery Indication: | |
Operating Temperature: | -10°C to 50°C |
Operating Humidity: | less than 85% relative |
Altitude: | up to 2000M |
Storage Temperature: | -20°C to 60°C |
Storage Humidity: | less than 75% relative |
Dimension: | 207mm(L) x 101mm (W) x 47mm (H) |
Weight: | 430g / 15.2oz (battery included) |
Accessories: | Users manual x 1 |
Remark:
Payment: Paypal, western union, credit card, bank transfer.
Warranty:1- 5 years
Defective rate: Less than 0.7%
MOQ: 1PCS
Packaging: Blister&package, gift box, carton
Delivery time: 2-7 days
OEM available
We are professionally manufacturing Power supply, LED Drivers,instrument
and meters and so on. Original quality, high-technic design, competitive price.
Welcome your inquiry!
Contact Us
- Hangzhou Gigamega New Energy Tech Co., Ltd.
- Contact nameHenrry Hu Chat Now
- Phone0086-571-85626768
- AddressNo.101-303,Linban Road,Banshan Town,Gongshu, Hangzhou, Zhejiang
Product Categories
LED Power Supply | Measurement & Meter | New Products |
New Products
-
( True RMS Clamp Meter ) TES Model: TES-3082
-
( AC Clamp Meter ) TES Model: TES-3040
-
( TRMS AC/DC Clamp Meter ) TES Model: TES-3050
-
( Prof. Clamp Meter ) TES Model: TES-3010/TES-3012
-
( DC/AC Clamp Meter ) TES Model: CM-01
-
( Clamp Meter/Automotive Clamp ) TES Model: CM-02
-
( Leakage Current Tester ) TES Model: CM-03
-
( DC/AC Current Probe ) TES Model: CM-05
-
( TRMS DC/AC Clamp Meter ) TES Model: CM-07
-
( AC/DC mA True RMS Clamp Meter ) TES Model: PROVA-11
-
( AC/DC mA Current Probe ) TES Model: PROVA-15
-
( Clamp Meter ) TES Model: PROVA-2000/PROVA-2003
Popular Searches
- Auto Meter
- multimeter
- analog multimeter
- Digital Frequency Meter
- digital multimeter
- dmm
- Multimeters
- Small Multimeter
- Power Meter Multimeter
- Portable Multimeter
- Digital Capacitance Multimeter
- Clamp Meter Multimeter Ac
- Ac/dc Clamp Multimeter
- ranging meter
- multimeter digital
- Smart Multimeter
- Pointer Multimeter
- Digital Auto Range Multimeter
- Lcd Display Multimeter
- ac clamp multimeter
- fluke multimeters
- professional digital multimeter
- fluke digital multimeter
- frequency multimeter
- digital multimeter test
- digital panel multimeter
- multimeter test leads
- multimeter professional
- low price digital multimeter
- pocket multimeter
Recommended Products
- 20 Years Instruments Factory Vicimeter CM-2016 Clamp Multimeter with AC DC 800A Current and True RMS NCV Tests
- Vici CM-2018 AC DC Clamp Meter with LPF Loz Rel T-RMS NCV Tests
- Vicimeter VC4060C Insulation Milliohm Inductance Motor Checker Tester
- Motor Checker Insulation Resistance Milliohm Inductance Tester
- Vicimeter CM-3000 Large Display Screen No Knob AC Clamp Meter
- Vicimeter CM-3002 Oversize Color LCD 800A AC DC Smart Auto Clamp Meter
- Vicimeter VC835B Auto Range 2000 Digits Multimeter
- Vicimeter VC732A Auto Range 2000 Digits Multimeter
- Vicimeter 2-IN-1 VC4060B Insulation Tester Multimeter
- Vicimeter VC4060AT Insulation Multimeter
- Vicimeter VC746A T-RMS NCV LIVE REL ACA DCA ACV DCV OHM Fara Hz Temp Detecting 6000 Digits Multimeter
- Fluke Digital Multimeter F115C117C Handheld high precision digital display multimeter 175179C287C289C
Find Similar Products By Category
- Instruments & Meters > Meter for Electricity > Multimeter
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Henrry Hu
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile