Home > Products > Electrical Products > Custom AC Clamp On Rogowski Coil Current Probe
Custom AC Clamp On Rogowski Coil Current Probe
- Beijing
- Credit Card
You May Like
Product Details
Place of Origin | Beijing, China | Brand Name | GFUVE | |
Model Number | FQ-RCT02 | Usage | Current | |
Phase | Single | Coil Structure | Toroidal | |
Coil Number | Autotransformer |
Product Description
Custom AC Clamp On Rogowski Coil Current Probe
The FQ-RCT02 Flexible AC current probe are designed for easy installed in tight spaces and without the need for dismantling the primary busbar or cables.
Applications
Power quality monitoring
Power meters
Smart logger
Energy sub-meters
Distributed measurement systems
Features
Flexible and light weights
Easy & quick installation in tight spaces
No danger from open-circuited secondary
No core saturation or damage if overloaded
Excellent linearity
Multi-size are available
General data
Ambient operating temperature: -20~+70
Ambient storage temperature: -25~+75
Standards Safety:IEC 61010-1:2001, 600 V CAT III
Dimension
Dimensions(mm) | FQ-RCT02-120 FQ-RCTA02-120 | FQ-RCT02-190 FQ-RCTA02-190 | FQ-RCT02-305 FQ-RCTA02-305 |
Window A | 120 | 190 | 305 |
Coil OD B | 145 | 205 | 335 |
Coil Length C | 400 | 600 | 1000 |
Output connection | 1. UL2586-ESB 2*24AWG L=150cm (as required) 2. Coax terminated with safety male BNC connector L=300cm (as required) 3. UL2586-ESB 2*24AWG L=150cm(as required) with integrator |
Model Data | CY-RCT02-120 | CY-RCT02-190 | CY-RCT02-305 | CY-RCTA02-120 | CY-RCTA02-190 | CY-RCTA02-305 | |
Current Range | 10A~30kA | 10A~6000A | |||||
Frequency | 25Hz~20kHz | 45Hz~600Hz | |||||
Output Voltage | Rated current | 1000A | 2000A | 3000A | 1000A,1500A 2000A,3000A | 2000A,3000A,5000A,6000A | 3000A,4000A, 5000A,6000A |
50Hz | 100mV AC | 200mV AC | 300mV AC | 333mV | |||
1mV/A@1000-3000A(0.5mV/A@4000-6000A) | |||||||
Max output | / | 3.0V AC max | |||||
Accuracy | <1% @25°C (45-65Hz) | <1% @25°C (45-65Hz) | |||||
Phase error | <60’ @25°C (45-65Hz) | <60’ @25°C (45-65Hz) | |||||
Output sensitivity | ±2% Max (No Calibration) | 1% | |||||
±0.5% @25°C (With Calibration) | |||||||
Linearity error | ±0.2% (10%-100%I1n) | ±0.2% | |||||
Position Sensitivity | ±2% | ±2% | |||||
External Influence | ±2% Max | ±1.5% Max | |||||
Power Supply | / | 10-30VDC, 30mA Max. |
Contact Us
- Beijing GFUVE Electronics Co., Ltd.
- Contact nameAndy Huang Chat Now
- Phone86-10-85782698
- AddressBldg. 1-1006, Joy Mansion, No. 99, Chaoyang North Road
Product Categories
Applications | Current Transformer | Electrical Accessory | Electrical instruments |
Electrical Products | Handheld Terminal | New Products | Voltage Transformer |
New Products
-
GF312D1Portable three phase kwh meter field testing set
-
FU-30 Split Core PC material Current transformer
-
FU-120 Split core busbar current transformer
-
Digital multifunction calibrator
-
FU-120 Split core current transformer
-
Handheld Single-Phase Energy Meter Site calibrator
-
GF302D portable three phase Kwh meter calibration equipment
-
Outdoor type current transformer for measurement
-
10KV ABS PC Material measurement current transformer
-
Outdoor low voltage current transformer
-
Resin Split-core current transformers
-
35Kv Protect Current Transformer
Popular Searches
- power transformer
- Distribution Service
- current transformer
- power transformers
- High Frequency Transformer
- Electrical Transformer
- energy saver device
- led transformers
- step up converter
- Ac Drive Converter
- Frequency Drive Converter
- lightning conductor
- Copper Lightning Rod
- electronic transformer
- Lighting Transformers
- toroidal transformer
- auto transformer
- current transformer inductor
- voltage transformer
- Control Transformer
- Power Supply Transformer
- Led Lighting Transformer
- Waterproof Transformer
- Electric Transformer
- Low Frequency Transformer
- Flyback Transformer
- Core Transformer
- pot & kettle
- Output Inductor
- Power Distribution Equipment
Recommended Products
- Bently Nevada 84661-60
- Bently Nevada 9571-50
- Bently Nevada 190501-00-00-CN
- Bently Nevada 330425-02-CN
- Bently Nevada 330400-02-CN
- Bently Nevada 330500-07-02
- Bently Nevada 330500-01-04
- Bently Nevada 330904-00-03-70-01-CN
- Bently Nevada 330905-00-03-10-02-00
- Bently Nevada 330901-00-08-05-02-05
- Bently Nevada 330930-045-00-05
- Bently Nevada 330130-045-03-05
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andy Huang
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile