Condition | New | Place of Origin | Jiangsu, China | |
Brand Name | KaiSheng | Model Number | ks-91 | |
Structure | Tube Heat Exchanger | Liquid Flow Rate | 6.6 m*m*m/h | |
Maximum Working Pressure | 9.9mpa | Voltage | 220/380V | |
Weight | 1-2ton | Dimension(L*W*H) | 800-3000mm | |
Power(W) | 1hp-100hp | Certification | CE | |
Warranty | one year | After-sales Service Provided | Engineers available to service machinery overseas |
Product Description
Specifications
shell pipe heat exchanger made of stainless steel,caron steelhost material:15CrMoR/15CrMo/S30408
good price+high quality
Shell and tube Type heat exchanger manufacturer
How does the shell and tube heat exchanger work?
A shell and tube heat exchanger is the most common type of heat exchanger in oil refineries and other large chemical processes, and is suited for higher-pressure applications. As its name implies, this type of heat exchanger consists of a shell (a large pressure vessel) with a bundle of tubes inside it. One fluid runs through the tubes, and another fluid flows over the tubes (through the shell) to transfer heat between the two fluids. The set of tubes is called a tube bundle, and may be composed of several types of tubes: plain, longitudinally finned, etc.
Two fluids, of different starting temperatures, flow through the heat exchanger. One flows through the tubes (the tube side) and the other flows outside the tubes but inside the shell (the shell side). Heat is transferred from one fluid to the other through the tube walls, either from tube side to shell side or vice versa. The fluids can be either liquids or gases on either the shell or the tube side. In order to transfer heat efficiently, a large heat transfer area should be used, leading to the use of many tubes. In this way, waste heat can be put to use. This is an efficient way to conserve energy.
Heat exchangers with only one phase (liquid or gas) on each side can be called one-phase or single-phase heat exchangers. Two-phase heat exchangers can be used to heat a liquid to boil it into a gas (vapor), sometimes called boilers, or cool a vapor to condense it into a liquid (called condensers), with the phase change usually occurring on the shell side. Boilers in steam engine locomotives are typically large, usually cylindrically-shaped shell-and-tube heat exchangers. In large power plants with steam-driven turbines, shell-and-tube surface condensers are used to condense the exhaust steam exiting the turbine into condensate water which is recycled back to be turned into steam in the steam generator.
Types of shell and tube heat exchanger
There can be many variations on the shell and tube design. Typically, the ends of each tube are connected to plenums (sometimes called water boxes) through holes intubesheets. The tubes may be straight or bent in the shape of a U, called U-tubes.
In nuclear power plants called pressurized water reactors, large heat exchangers called steam generators are two-phase, shell-and-tube heat exchangers which typically have U-tubes. They are used to boil water recycled from a surface condenser into steam to drive a turbine to produce power. Most shell-and-tube heat exchangers are either 1, 2, or 4 pass designs on the tube side. This refers to the number of times the fluid in the tubes passes through the fluid in the shell. In a single pass heat exchanger, the fluid goes in one end of each tube and out the other.
Surface condensers in power plants are often 1-pass straight-tube heat exchangers (see Surface condenser for diagram). Two and four pass designs are common because the fluid can enter and exit on the same side. This makes construction much simpler.
There are often baffles directing flow through the shell side so the fluid does not take a short cut through the shell side leaving ineffective low flow volumes. These are generally attached to the tube bundle rather than the shell in order that the bundle is still removable for maintenance.
Counter current heat exchangers are most efficient because they allow the highest log mean temperature difference between the hot and cold streams. Many companies however do not use single pass heat exchangers because they can break easily in addition to being more expensive to build. Often multiple heat exchangers can be used to simulate the counter current flow of a single large exchanger.
Applications and uses
One of the most common applications is the cooling of hydraulic fluid and oil in engines, transmissions and hydraulic power packs. With the right choice of materials they can also be used to cool or heat other mediums, such as swimming pool water or charge air.
tube material
All of these requirements call for careful selection of strong, thermally-conductive, corrosion-resistant, high quality tube materials, typically metals, including copper alloy,stainless steel, carbon steel, non-ferrous copper alloy, Inconel, nickel, Hastelloy and titanium. Poor choice of tube material could result in a leak through a tube between the shell and tube sides causing fluid cross-contamination and possibly loss of pressure.
Product photo
Contact Us
- Wuxi Kaisheng Electricity Petrochemical Equipment Co., Ltd.
- Contact nameKai Sheng Chat Now
- Phone86-510-85539300
- AddressShiliu Road, Hongxiang, Hudai, Binhu, Wuxi, 214161, Jiangsu, China, Wuxi, Jiangsu
Product Categories
Bars | Finned Tubes | Flanges | Gaskets/Spacers |
New Products | Parts for Pressure Vessels | Pipe end cap/Seal head | Studded Tubes |
Tube Sheet & Baffles | Tubes |
New Products
-
welding electrodes
-
Gr2 ASTMB 338 Titanium tube
-
Price of Seamless Titanium tube
-
Titanium PIPE
-
od19.05*1.65T*6100mm TITANIUM TUBE
-
titanium pipe price
-
longitudinal finned tube
-
spiral finned tube
-
extruded finned tube
-
spiral copper alloy finned tube
-
finned tube
-
alloy spiral finned tube
-
alloy spiral / square / longitudinal finned tube
-
alloy spiral / square / longitudinal finned tube,stainless finned tube
-
ERW alloy spiral / square / longitudinal finned tube,stainless finned tube
-
ERW alloy aluminum spiral / square / longitudinal finned tube,stainless finned tube
-
ERW square finned tube,stainless finned tube
-
Square stainless finned tube,stainless finned tube
-
Alloy Square stainless finned tube,stainless finned tube
-
Alloy Square /spiral stainless finned tube,stainless finned tube
-
Alloy Square /spiral .longitudinal stainless finned tube
-
Customized special finned tube,stainless finned tube
-
all kind finned tube,stainless finned tube
-
all kind finned tube,alloy finned tube
Popular Searches
- Air Conditioner Compressor
- heat exchanger
- oil cooler
- heat recovery
- heating plate
- heat exchange
- Plate Heat Exchanger
- Heat Pipe Cooler
- refrigerator water cooled condenser
- water heater gas
- Plate Heat Exchanger Gasket
- heat radiator
- heat exchange equipment
- oil radiator
- Condenser Unit
- condense
- Refrigeration & Heat Exchange
- air heat exchanger
- Fin Tube
- Air Cooled Condenser
- Heat Exchanger Plate
- Wire Condenser
- Refrigeration & Heat Exchange Parts
- Refrigerator Condenser
- heat exchanger tube
- calorifier
- Air Oil Cooler
- Air Compressor Oil Cooler
- Hydraulic Oil Cooler
- Air Condition Compressor
Recommended Products
- STF permanent magnet solenoid valve coil best 0210 AC220V 16VA 24V 18VA air conditioning cold storage coil
- Danfoss dryer filter DML085 023Z507391
- Lefukang compressor photoelectric switch INT276LC .INT276LN photoelectric oil level switch OLC-D
- OLC-D1 Bitzer BITZER Compressor Photoelectric Oil Level Switch Level Sensor 3479490
- Bitzer OLC-D1 cold storage compressor photoelectric switch refrigeration compressor photoelectric oil level switch level sensor
- Bitzer oil separator; OLC-D1 photoelectric oil level switch sensor 34794901
- Bitzer OLC-D1 34794901 Bitzer compressor photoelectric switch screw machine photoelectric switch oil level
- Bitzer compressor photoelectric liquid level switch OLC-D1 Lufukang oil level sensor INT276LN oil fraction C
- Electronic oil pressure differential switch OUT571 Bizerba DELTA-PⅡ 22D57 Fujihao Douling 3471711
- Anhydrous Calcium Chloride Granulation & Drying System
- Bitzer Compressor Electronic Oil Pressure Differential Switch OUT571 / DELTA-P II BITZER 3473171
- BITZER compressor oil separator optical level switch OLC-D1 sensor 34794901
Find Similar Products By Category
- Industrial Equipment & Components > Heater & Heat Exchanger > Heat Exchanger
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Kai Sheng
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile