Home > Products > New Products > 5KV Polymer Lightning Surge arrester
5KV Polymer Lightning Surge arrester
- NINGBO SHANGHAI
- T/T Credit Card PayPal
You May Like
Product Details
Place of Origin | Zhejiang, China | Brand Name | Mingneng | |
Model Number | HY5WS-5/15 |
Product Description
Specifications
material: ZnO varistor, sillicon rubber housingcertification:ISO9001
package: Carton
confirm to IEC60099-4, IEC37-199/CDV
This surge arrester is used to protect distribution equipment from being damaged by atmosphere over-voltage and operating over-voltage.
NO.1 Brief Introduction:
Lightning arrester (surge arrester) housed in porcelian and polymer housings, is developed to protect switchgear, overhead lines, transformers, and other equipment against atmospheric or a system-immanent over-voltage.
In medium-voltage distribution systems the arresters are widely spread over the whole network as they are normally directly arranged either, for instance, at the pole-mounted transformers, or at the cable terminations.
NO.2 Construction:
Certain designs of the polymer housed arresters were in fact impossible to construct until the gapless metal-oxide technique was introduced. As a major progress, metal oxide arresters could be built with only one single effective active element, namely the column of the metal oxide resistors. High demands are, however, made on these metal oxide resistors, as they combine all the functions, which previously had been shared among the different components of the gapped arrester. In this way they have to be ageing resistant while being subjected to constantly applied operating voltage. They must be able to absorb the energy injected during a discharge, and they should subsequently limit the follow current (leakage current) to value small enough for thermally stable operation.
The metal oxide resistor column, together with the accompanying supporting construction comprises the active part of the arrester. The column consists of individual metal oxide resistors stacked on top of each other. The metal oxide resistors are almost always produced in a cylindrical form. Their diameter decisively determines the energy absorption and the current carrying capability. It is within a range of about 30mm when used for distribution systems and up to 100mm or more for high and extra-high voltage systems and special applications, for which high energy absorption capabilities are required.
NO.3 Characteristics:
- Non-tracking and low erosion rates in polluted an non-polluted environments, long term weather ability,
- resistance to thermal ageing,
- UV resistance,
- chemical resistance.
- Tough, tear and impact resistance.
NO.4 Technical Parameters:
1) Sys R.V :3 KV(r.m.s)
2) MOA R.V :5 KV(r.m.s)
3) MCOV : 4.0 KV(r.m.s)
4) D.C.U1mA ≥8.0
5) 1/10 μs steep current impulse ≤17.3KV
6) 8/20 μs lighting current impulse ≤15KV
7) 30/60 μs switching current impulse ≤12.8KV
8) 2ms rectangular current impulse withstand:90A
9) 4/10μs high current impulse withstand:65KA
Model | Arrester Rated Voltage | MCOV | 1/10μs Steep Current Impulse | 8/20μs Lightning Current Impulse | 30/60μs Switching Current Impulse | 2ms Rectangular Current Impulse | 4/10μs High Current Impulse |
kV(r.m.s) | <kV | A | kA | ||||
HY10W-3 | 3 | 2.55 | 10.3 | 8 | 8.1 | 250 | 100 |
HY10W-6 | 6 | 5.1 | 20.5 | 16 | 15.5 | 250 | 100 |
HY10W-9 | 9 | 7.65 | 31 | 25 | 22 | 250 | 100 |
HY10W-10 | 10 | 8.4 | 33 | 27 | 24 | 250 | 100 |
HY10W-11 | 11 | 9.4 | 36.4 | 30 | 27.5 | 250 | 100 |
HY10W-12 | 12 | 10.2 | 38.5 | 33 | 29 | 250 | 100 |
HY10W-15 | 15 | 12.7 | 46.5 | 41 | 35 | 250 | 100 |
HY10W-18 | 18 | 15.3 | 56 | 49 | 42.5 | 250 | 100 |
HY10W-21 | 21 | 17 | 65.5 | 57 | 49.5 | 250 | 100 |
HY10W-24 | 24 | 19.5 | 75 | 65 | 56 | 250 | 100 |
HY10W-27 | 27 | 22 | 84 | 74 | 63.5 | 250 | 100 |
HY10W-30 | 30 | 24.4 | 93 | 82 | 72 | 250 | 100 |
HY10W-33 | 33 | 27.5 | 101 | 90 | 79 | 250 | 100 |
NO.5 Normal service conditions:
1.The ambient air temperature is no higher than +40 degree. no lower than -40 degree.
2.The altitude above sea level does not exceed 2000m
3.Power frequency 48Hz~62Hz
4.Maximum wind speed does not exceed 35m/s
5.The earthquake intensity does not exceed 7 degrees
6.The voltage that long-time exerted shouldn't exceed its Max MCOV
More Relevant Photos:
Contact Us
- Wenzhou Mingneng Electrical Co., Ltd.
- Contact nameleo shi Chat Now
- Phone0086-0577-62712995
- Address(Inside Yueqing Qiujing Auto Parts Stamping Factory) Bulao Village, Liushi Town
Product Categories
Counter/Monitor/Damper | Fault Indicator | Fuse Cutout | Lightning Arrester |
Limit Switch | MOV Varistors | New Products | Polymer Insulator |
Wall Busher |
New Products
-
cross-arm composite insulator
-
Types of Lighting Surge Arrester
-
Fall Arrest Equipment Systems Bleeding
-
Line type Thunder Surge Arrester 5KA with Gaps
-
15KV Lightening Arrester
-
35KV Three Phases Surge Arresters for Lightning Protection
-
Lightning Arrester Design for Lightning Protection System
-
JCQ-3 Discharge Counter and Leakage Current Meter
-
Partial Discharge monitor used for Surge Arrester
-
JCQ-3 surge lightning strike arrester monitor
-
JSM3-485 Digital Online Monitor for Metal Oxide Surge Arresters
-
lightning arrester surge arrester counter
Popular Searches
- power transformer
- Distribution Service
- current transformer
- power transformers
- High Frequency Transformer
- Electrical Transformer
- energy saver device
- led transformers
- step up converter
- Ac Drive Converter
- Frequency Drive Converter
- lightning conductor
- Copper Lightning Rod
- electronic transformer
- Lighting Transformers
- toroidal transformer
- auto transformer
- current transformer inductor
- voltage transformer
- Control Transformer
- Power Supply Transformer
- Led Lighting Transformer
- Waterproof Transformer
- Electric Transformer
- Low Frequency Transformer
- Flyback Transformer
- Core Transformer
- pot & kettle
- Output Inductor
- Power Distribution Equipment
Recommended Products
- Allen Bradley1756-IA32
- Allen Bradley1768-CNBR
- Honeywell FS-IOBUS-CPIOX6
- Honeywell FS-IOBUS-CPIO2
- Honeywell FS-IOBUS-CPX-1
- Allen Bradley2711E-T14C6
- Honeywell FS-BLIND-CHA3HE
- Honeywell FS-BLIND-CHA1HE
- Honeywell FS-BLIND-CHA4HE
- Digital Electronics UF7810-2
- Allen Bradley1761-L16BWA
- Siemens 6FC5370-0AA00-1AA1
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
leo shi
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile