Product Details
Type | Doppler Ultrasound Equipment | Brand Name | Jumper | |
Model Number | JPD-600P | Place of Origin | Guangdong, China |
Product Description
Multi-Parameters fetal monitor JPD-600P(7 inch) CE marked
Bedside care, normal hospital monitor
Standard configuration: FHR, TOCO, FM SpO2, NIBP, PR, Twins Function.
Feture:
1. Three in one transducers and avoid the cable intertwinsting, single probe also can offer, nine crystals probe, solid and durable, waterproof and with high sensitivity
2. Built-in fetus waking-up function
3.7 inch TFT color folding display, 90° Turnning angle
4. FHR, TOCO and FM can be displayed by mumber and curve, can changing-over by the user
5.12 hours data storage for review and printed
6. Wide voltage range (100-240V), suitable for different countries
7. Low power of ultrasound, harmless to fetus
8. Alarm function, mark for special and clinical patient, alarm upper and lower limit can be set by the user and the alarm method can optional
9. Adopt DSP technology, recognize and monitor the FHR in real time insure the result accurate and reliable
10. Built-in thermal printer, long using life, Print paper 112mm insure the printed curve clear, printing speed and density are adjustable
11. Information and RJ45 connector, can be connected in the hospital monitor center
12. Can work during charging, high anti-interference ability
GEL: Viscous aqueous non-sensitising, hypo-allergenic and non-irritating to skin. Indefinite shelf life, bacteriostatic (not sterile).
Technical Parameter:
Fetal Heart Rate:
Transducer: Multi-crystals, pulsed doppler , high sensitively
Strength: <5mW/cm2
Working frequency: 1.0MHz
Signal processing: special DSP system and modern recognization.
Measurement range: 60 bpm ~210 bpm
Alarm Range:
High limit: 160 bpm,170 bpm,180 bpm,190 bpm
Low limit: 90 bpm,100 bpm,110 bpm,120 bpm
Maximum audio output power : 1.5 Watt
Toco:
Measurement range: 0 units ~100 units
Maternal SpO2 measure:
Measure scope : 70%~99%.
Measure accuracy: ±3%
Pregnant HR Measure:
Measure scope: 30bpm~240bpm
Measure accuracy: ±2 bpm
NIBP measure:
a) NIBP-SYS 6.7Kpa~32.0Kpa (50mmHg~240mmHg)
b) NIBP-DIA 3.4Kpa~26.6Kpa (25mmHg~200mmHg)
c)NIBP-MEAN 2.0Kpa~24.0kpa (15mmHg~180mmHg)
NIBP Accuracy: ±1.1kPa(±8mmHg)or ±5% of the results, take the bigger one.
Maximum Mean error : ±5mmHg
Maximum Standard deviation 8mmHg
Pulse Rate Accuracy: Maximum Mean error : ±2bpm
Measure accuracy: ±2 bpm or ±5% of the results, take the bigger one.
Measure mode: Manual
Display:
The LCD displays FHR, TOCO, FM , maternal parameters , time, date, volume and so on, It can store and play back the data.
Power: a.c.100v - 240v, 50/60Hz ,d.c.15v or 16.8v Li-ION battery
Power Consumption: < 20W
Dimension: 307mm (length) ×296mm (width) ×101mm (height)
Net weight: Three-parameter type: 2.75kg; nine-parameter type: 3kg. (Both does not contain accessories such as probe)
Environment
Working environment: Temperature: +5ºC ~ +40ºC
Humidity: < 85%
Atmospheric pressure: 86kPa ~ 106kPa
Transport and storage temperature: Temperature: -10ºC ~ +55ºC
Humidity: < 93%
Atmospheric pressure: 86kPa ~ 106kPa
Transducer Acoustic Output:
Under the requirements laid down in IEC 1157, 1992, the peak negative acoustic pressure
does not exceed 1Mpa. The output beam intensity does not exceed 20mW/cm2
and the spatial-peak temporal-average intensity does not exceed 100mW/cm2
Technical parameters | |||
Ultrasound frequency | 1MHz± 5% | ||
Power supply | AC100~240V 50/60Hz | ||
Working temperature (centidegree) | 5~40 | ||
Working humidity | < 85% | ||
Working atmospheric pressure (KPa) | 86~106 | ||
Storage temperature (centidegree) | -10~+55 | ||
Storage relative humidity | < 93% | ||
Storage atmospheric pressure | 86~106 | ||
Machine0.2% Dimension (mm) | |||
Net weight | |||
FM | Button hand count automatic cumulative number of movement | ||
ECG | Range | 30~300bpm | |
Accuracy | ± 1bpm | ||
Choice | I, II. III, AVR, AVL, AVF, V | ||
Scan speed | 12.5/25/50mm/s | ||
Gain choice | *0.25, *0.5, *1, *2 | ||
Application | Diagnosis, monitor, surgery | ||
RESP | Range | 1~99rpm | |
Resolution | 1rpm | ||
Accuracy | ± 2rpm | ||
TEMP | Range | 26~45 centidegree | |
Resolution | 0.1centidegree | ||
Accuracy | ± 0.2% | ||
FHR | Ultrasound intensity | < 5mW/cm 2 | |
Measure range (bpm) | 50~210 | ||
Alarm range (bpm) | H: 160/170/180/190 | ||
L: 90/100/110/120 | |||
Maximum audio output power | 1.5W | ||
TOCO | Measure range | 0~100 unit | |
Resolution | 1 | ||
Non-linear error | ≤ ± 5% | ||
Maternal HR | Measure scope (bpm) | 30~240 | |
Measure accuracy (bpm) | ± 2 | ||
Maternal SPO2 | Measure scope | 70%~99% | |
Resolution | 1% | ||
Measure accuracy | ± 2bpm | ||
NIBP | Systolic pressure | 50~240 mmHg | |
Diastolic pressure | 15~180 mmHg | ||
Mean pressure | 25~200 mmHg | ||
NIBP accuracy | ± 8mmHg | ||
PR | PR range | 40~240bpm | |
Mode | Automanual | ||
Resolution | 1 mmHg | ||
PR accuracy | ± 2bpm |
Faults | Probable causes | Approaches |
No displaying after start | Power cord is not plugged well Power failure or poor power plug or socket | Inspect the power and power cord |
When start the instrument, the LCD interface is normal but can't move the cursor. | Poor or broken connect between fetal monitoring module and motherboard | Connect again or replace the module |
Fetal heart rate is abnormal | Poor connect of probe and connector The probe position is wrong and the probe does not find fetal heart. No coupling agent or the coupling agent is too little. Fetus/Pregnant women's movement The probe is broken. | Connect again Readjust the probe position Add coupling agent When there is signal again, readjust the probe position. Replace the probe. |
Uterine contraction is abnormal | Poor connect of probe and instrument The probe position is wrong. The pressure has not been reset. Pregnant women have no uterine contraction | Connect again Readjust the probe position Reset the pressure Wait for uterine contraction |
When press the pressure probe, there is no change or little change of the uterine contraction numerical value. | Drift of pressure probe internal circuit or the pressure probe is broken | Adjust the potentiometer in the side holes of pressure probe by straight screwdriver fixing watches to make the probe can read normal numerical value when pressing. Replace the pressure probe. |
Press fetal movement pen, there is no display and printing icon. | Poor contact of scaler button switch | Inspected and determined by universal meter |
The speaker is mute. | The volume is too low. | Turn up the volume. |
The paper is running but no printing curve. Fetal heart curve is printed in uterine contraction area and uterine contraction curve is printed in fetal heart area. | The placement of thermal printing paper is adverse. The left and right sides of thermal surface are adverse. | Inspect whether thermal surface is upward and place paper again Take out the thermal paper and place again. |
The printing is not clear or there can't print in partial area. | The printing denseness is set too light Poor printing paper has been used or the printing paper is subject to deterioration The printing thermal head is dirty. | Adjust printing denseness Replace printing paper Clean printing head in sequence. |
The paper feed is deviated and there is error of the printing curve position. |
Contact Us
- Shenzhen Jumper Medical Equipment Co., Ltd.
- Contact namecherry huang Chat Now
- Phone86-755-26696279-811
- Address7th to 10th FL.,East district ,No.71-4, Building D,Xintian Avenue,Fuyong street ,Baoan district ,Shenzhen,China, Shenzhen, Guangdong
Product Categories
Blood Pressure Monitor | Digital Fetal Doppler | ECG Machine | Fetal Monitor & Maternal monitor |
Handy Nebulizer | Infrared Thermometer | New Products | Patient Monitor |
Pulse Oximeter | Veterinary Monitor |
New Products
-
Jumper Fetal/ Maternal Monitor Jpd-600p 7", CE&ISO13485 Proved
-
Angelsounds mini lightweight ultrasonic nebulizer jpd-100n
-
facial moisturizer spray
-
facial mist spray
-
nano handy mist spray for skin care facial
-
vacuum & spray facial machine
-
facial spray nano mist
-
nano spray facial skin care
-
Hydrophobic nano spray, Facial Moisture Spray
-
moist beauty skin lotion,Facial Moisture Spray
-
Nano Spray-Facial moisture spray,a new kinds of product.CE marked
-
China mini handy ultrasonic nebulizer for beauty care facial steamer ,CE,FCC,ROHS marked
-
portable mini ultrasonic nebulizer with battery for Nano tiny particles
-
CE marked mini ultrasonic nebulizer
-
nanotechnology products,facial steamer ,Nano moist mist ,CE FCC ROHS marked
-
Facial Moisture Mist Spray ,mini,for skin care,CE&FCC&ROSH marked,Office lady use.
-
portable H2O hydrophobic spray CE FCC ROSH JPD-100N
-
iBeauty Nano Handy Mist, Handy Moist Mist, Facial Spray Nano Mist
-
Portable iBeauty nano handy mist facial mist nano mist,Hand-held mini face sprayer,handy moist mist
-
Nano facial steamer for mesh nebulizer CE,FCC,ROHS marked Jumper
-
nanotechnology products facial steamer,handy moist mist CE,FCC,ROHS marked
-
nanotechnology products facial steamer CE ,FCC,ROSH marked JPD-100N Jumper
-
nanotechnology products handy face spray nebulizer CE FCC ROSH certified
-
nanotechnology products facial steamer CE,FCC,ROHS marked
Popular Searches
- digital endoscopes
- ophthalmic yag laser
- ultra sound machine
- endoscopy olympus
- endoscopy camera system
- mindray dp
- vein illuminator price
- analyzing skin uv scanner machine
- digital electronic colposcope
- a.1. endoscopes
- a.1. endoscope
- ac ultrasound
- acs recovery
- all shares
- angelsounds fetal doppler
- Bar Probe
- armed heart monitors
- be ultrasonic
- bende sections
- best ge
- big ultrasound
- bar code scanner system
- Beat Monitor
- breast analyzer infrared
- breast infrared detector
- biomet
- Car Probe
- cat pigs
- Ce Doppler
- ce probe
Recommended Products
- Precision LY-10A-20 Hand Lens Edger for Detailed Craftsmanship & Professional Eyewear Manufacturing, High-Quality Optical Tool
- Top Quality Hand Edger Optical Manual Lens Cutting Machine NH-35WV CLASS B
- LY-5D-35WV Hand Lens Edging Polishing Machine Optical Manual Grinder Polisher
- NH-100 Optical Grinding Machine High Speed Hand Lens Edging Manual Edger
- CP-6A Optical Manual Lens Edger Best Selling Hand Edger CE Certificate Hand Lens Edger Lens Grinder
- China Optometry Equipment High Quality Patternless SJG-800 Auto Lens Edger Price for Sale
- SJG-5188 Optical Laboratory Equipment Auto Lens Edger Machine for Eyeglasses Store
- SJG-5188 Optical Auto Lens Edger China Optical Auto Lens Edger Edging Machine
- ALE-1000+ST-1200 Optical Machine Automatic Lens Edging Machine 2D Patternless Auto Lens Edger
- ALE-1000+ST-1200 Ophthalmic Glasses Edging Device Optical Auto Patternless Lens Edger Machine
- ALE-1000+ST-1200 Ophthalmic Glasses Edging Device Optical Auto Patternless Lens Edger Machine
- ALE-1000+ST-1200 2D Optical Equipment Top With CE Patternless Auto Lens Edger Machine
Find Similar Products By Category
- Health & Medicine > Medical Equipment > Ultrasonic, Optical, Electronic Equipment
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now
Shenzhen Jumper Medical Equipment Co., Ltd.
AIBot OnlineThis conversation is AI-generated. Contact manufacturer before transaction to confirm info.
-
cherry huang
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile