Home > Products > New Products > air flow meter,gas flow meter
air flow meter,gas flow meter
- Shanghai / Tianjin
- T/T L/C D/P D/A
You May Like
Product Details
Place of Origin | Shaanxi, China | Brand Name | Qinwei | |
Model Number | HL-LWS |
Product Description
Specifications
air flow meter,gas flow meter1,High accuracy
2,Good stability,corrosive material
3,Meter the gas
samrt flow meter,compressed air Flow Meter
1,High accuracy1.0%,1.5%
2,Good stability,corrosive material
3,Meter the gas,s
samrt flow meter,compressed air Flow Meter
Product Description
The LUGB type vortex street air flow meter is a kind of volume flowmeter to measure the volume flow of gas, steam or liquid, volume flow and mass flow in standard conditions based on Karman vortex principle, and it can be used in the automation control system as flow transducer.
Flow Range
Instrument Diameter (mm) | Liquid |
| ||
Measurement range (m3/h) | Range of output frequency (Hz) | Measurement range (m3/h) | Range of output frequency (Hz) | |
25 | 1.2~16 | 25~336 | 8.8~55 | 190~1140 |
32 | 1.5~20 | 16~286 | 10~160 | 160~1090 |
40 | 2~40 | 10~200 | 27~205 | 140~1040 |
50 | 3~60 | 8~160 | 35~380 | 94~1020 |
65 | 4.5~90 | 6.2~124 | 40~780 | 68~860 |
80 | 6.5~130 | 4.1~82 | 86~1100 | 55~690 |
100 | 15~220 | 4.7~69 | 133~1700 | 42~536 |
125 | 20~320 | 3.5~65 | 140~3260 | 35~492 |
150 | 30~450 | 2.8~43 | 347~4000 | 33~380 |
200 | 45~800 | 2~31 | 560~8000 | 22~315 |
250 | 65~1250 | 1.5~25 | 890~11000 | 18~221 |
300 | 95~2000 | 1.2~24 | 1360~18000 | 16~213 |
(300) | 100~1500 | 5.5~87 | 1560~15600 | 85~880 |
(400) | 180~3000 | 5.6~87 | 2750~27000 | 85~880 |
(500) | 300~4500 | 5.6~88 | 4300~43000 | 85~880 |
(600) | 450~6500 | 5.7~89 | 6100~61000 | 85~880 |
(800) | 750~10000 | 5.7~88 | 11000~110000 | 85~880 |
(1000) | 1200~1700 | 5.8~88 | 17000~170000 | 85~880 |
> (1000) | Determined through negotiation |
| Determined through negotiation |
|
qualification: P-101.325kPa, T=293.15K (also could take 273.15K as 0°Cstatus according to requirement)
Service condition:
Ambient temperature:-30°C~+50°C medium temperature: 20°C ~+80°C
Relative humidity: 5%~95% Atmospheric pressure: 86KPa~106KPa
The pressure loss of flowmeter: gas pressure loss shown in the above table, liquid remains undetermined
Electric performance indexes:
a. Operating power supply
Inner power supply: a 3.6V lithium battery, the screendisplays the battery capability in real time, the battery voltage within 2.9~3.6V could operate normally; when the voltage is lower than 2.9V, appears voltage shortage indication
External power supply: +24VCD±5%, ripple ≤±5%, when connecting external power supply, inner power supply cuts off automatically, and the whole machine operates with exterior power supply.
b. Output manner (Require additional power +24V)
Pulse signal of operating condition (three-wire system): Amplify and output the pulse signal of operating condition detected by flowmeter sensor, up level≥20W, low level≤1V, transmission distance≤300m.
4~20mA standard analog amount signal: 4~20mA standard analog amount signal line is in correspondence with 0~Qmax (standard flow), flow range is set by instrument, transmission distance ≤300m, power supplier is +24VDC exterior power.
RS485 interface signal: networking with the up-machine directly could transmit detected temperature, pressure, instant flow, standard volume flow and relevant instrument parameters, etc. And by matching with special MODEM could carry out telephone communication.
The entire machine consumption:
- Inner power: average consumption is 3mw, one lithium battery (15Ah) could be used for more than two years.
- Exterior power: the entire machine consumption ≤1W
The function of real time data storage:
In order to adapt to the requirements in data management, the real-time data storage function is added, including:
- Recent 400 times’ starting and stopping time and corresponding flow net value.
- Latest twelve months’ monthly net flow
- Latest three hundred and sixty days’ each day net flow
Above storage data could be read and fetched by using a laptop PC or desktop computer through RS485 interface, analyzing according to the user formed data statement and curve figure.
The pressure loss of flowmeter
- Under standard condition, the pressure loss P of each specified flowmeter could be checked out according to figure 4 when the medium is in the form of dry air.
- Under different conditions and for various mediums , the pressure loss of flowmeter could be calculated according to the formula below:
P =Po. p/1.205
In this formula: P---the actual pressure loss of flowmeter (kPa)
p----The medium density under actual condition (kg/m2 )
Po--- The pressure loss when the medium is dry air under standard condition (kPa)
Contact Us
- Xian Qin Wei Instrument Factory
- Contact nameJay Cen Chat Now
- Phone0086-029-84212812
- AddressRm. 1-1401, 14/F, Unit 1, No. 1 Bldg., Huahao Lidu, No. 129, Daqing Road, Lianhu District
Product Categories
Calibration instruments | Flow meters | Level products | New Products |
Pressure gauges | Pressure transmitters | Temperature products | Water meters |
New Products
-
pulse output fluid turbine flowmeter instruments,ISO Certificated
-
glass water flow meter/Panel Flow Meter/LZT-10
-
variable area metallic flowmeter
-
variable-area metallic measuring tube flowmeter
-
compressed air flowmeter/turbine flowmeter(ISO9001 manufacture)
-
turbine type compressed air flowmeter
-
digital compressed air flowmeter/turbine flowmeter(ISO9001 manufacture)
-
thread screw connection turbine flowmeter
-
flange connection turbine flowmeter
-
clamp type turbine flowmeter
-
Smart Stainless Steel Gas Turbine Flowmeter for Liquid /Oil with Signal Output &Local Display
-
gas turbine flowmeter for natural gas flow meter
Popular Searches
- air flow meter
- Hour Meter
- Digital Clamp Meter
- temperature meter
- Meter Counter
- Energy Meter
- Clamp Meter
- Frequency Meters
- Clamp Meters
- flow meter
- air flowmeter
- Ultrasonic Flow Meter
- Water Flow Meter
- Turbine Flow Meter
- Sewage Flow Meter
- Vortex Flow Meter
- Ac Clamp Meter
- Magnetic Flow Meter
- alcohol meter
- correction liquid
- Energy Meters
- Flow Measuring Instruments
- water flowmeter
- flow sensor water
- liquid control meter
- oil flow meter
- flow measurement
- water flow rate meter
- flow indicator
- liquid flowmeter
Recommended Products
- 7ML5746-2DA30-1AA0-Z Y17 Siemens point level gauge 7ML5747-2AB24-1BA0
- Alicat MWB Low Pressure Loss Series Portable Series Gas Mass Flow Meter
- Alicat MB Series Portable Series Gas Mass Flow Meter
- Alicat Standard M-Series Gas Mass Flow Meter
- Alicat MC Standard Series Gas Mass Flow Controller
- Ufm/universal flow monitors flow switch MN-DSF300LM-16-1050
- Siemens 840D Handwheel 6FX2007-1AC04/1AE14/1AC14/1AC04 CNC Pendant Unit Currently
- Siemens7ML1998-5NE11/MANUAL, SITRANS LUT400 COMMUNICATIONS, FRENCH
- 7ML1998-5NE01/MANUAL, SITRANS LUT400 COMMUNICATIONS, ENGLISH
- 7ML5740-2AA11-0A/Universal input, panel-mounted digital display. RD200, power supply 12-36 V DC, MODBUS.
- 7ML5740-2AC01-1A/ IS A UNIVERSAL INPUT, PANEL MOUNT REMOTE DIGITAL DISPLAY FOR PROCESS INSTRUMENTATION. RD200 12-36 VDC DISPLAY WITH 4-20,2X
- 7ML5811-1A/up to 20 relay outputs, switchable AC/DC power supply, certifications CSA NRTL/C, FM, CE.
Find Similar Products By Category
- Instruments & Meters > Meter for Liquid & Gas > Flow Meter
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Jay Cen
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile