Place of Origin | Shaanxi, China | Brand Name | FORESIGHT | |
Model Number | FST-60 | Size | 125 x 52 x 41 mm | |
Measurement Accuracy | ±1.5mm | Measurement Range | 0.15-60m |
Product Description
Applications:
1. Road traffic
2. Automotive anti-collision
3. Construction survey and design
4. Levelmaterial level detection
5. Robot arm control
6. Fixed length control of container crane spreader
7. Security monitoring
8. Military applications
Laser Distance Sensor | FST-60D | FST-60A | FST-60K |
Measuring Range | 0.15m to 60m* | 0.15m to 60m* | 0.15m to 60m* |
Measurement rate ( Up to ) | 5Hz | ||
Measuring accuracy | typ:±1.5mm** | typ:±1.5mm** | typ:±1.5mm** |
Smallest unit displayed | 1mm | N/A | N/A |
Laser class | II | ||
Laser type | 635nm,<1mW | 635nm,<1mW | 635nm,<1mW |
Laser beam diameter approx. -at 10m distance -at 50m distance
|
6mm 30mm |
6mm 30mm |
6mm 30mm |
Measurement time | 20-100ms | ||
Measuring mode -trigger measuring -continuous measuring |
yes yes |
yes yes |
yes yes |
Operation mode | commands by computer | commands by computer | commands by computer |
Output mode | Digital output: RS232 serial output | Analog output: 4-20mA current output | Switch output: 2 ways switch output |
Power supply | DC 5V/1A | DC 24V/1A | DC 5V/1A |
Power consumption | <3W | <3W | <3W |
Storage Temperature | -25℃ to 70℃ | -25℃ to 70℃ | -25℃ to 70℃ |
Operating Temperature | 0℃ to 40℃ | 0℃ to 40℃ | 0℃ to 40℃ |
Dimension | 125 x 52 x 41 mm | 125 x 52 x 41 mm | 125 x 52 x 41 mm |
Housing material | Aluminium alloy | ||
Protection class | IP67 | ||
Standards applied | IEC 60947-5-2 | ||
Certifications | CE,FDA | ||
Standards applied | IEC 60947-5-2 | ||
Weight | 185g | 185g | 185g |
Using instructions
1 Cable connecting definitions
Red line —— +5V
Black line —— PGND
Yellow line —— T/R-
Green line —— T/R+
Blue line —— DGND
2 Operating Steps
2.1 Connect a sensor to the serial port of computer (or other device which have serial ports) and the power port of adapter with special data cable.
2.2 Trigger Measuring
2.2.1 Send the command “O” (ASCII) or “0X4F” (HEX) by computer to turn on the sensor. Then the sensor will turn on the laser and prepare for working, and return the data “FF 00 0A 0A 0A 00” to the serial interface.
2.2.2 Send the command “O” (ASCII) or “0X4F” (HEX) again to the sensor to start to measure distance. The sensor will return the measured data like “FF XX XX XX XX XX” to the serial interface and turn off the laser when it finished one time measurement.
2.2.3 Send the command “U” (ASCII) or “0X55” (HEX) to turn off the sensor.
2.3 Continuous Measuring
2.3.1 Send the command “O” (ASCII) or “0X4F” (HEX) by computer to turn on the sensor. Then the sensor will turn on the laser and prepare for working, and return the data “FF 00 0A 0A 0A 00” to the serial interface
2.3.2 Send the command “C” (ASCII) or “0X43” (HEX) to the sensor. The sensor will begin to measure continuously after 3 seconds when it got the order, and return the data continuously like “FF XX XX XX XX XX”. If the sensor couldn’t get any available data, it will return “FF 00 0A 0A 0A 00” to the serial interface.
2.3.3 Send the command “U” (ASCII) or “0X55” (HEX) to turn off the whole sensor (include both of laser unit and measuring unit).
Input and output
1 Data format for RS232 serial communication
Baud rate: 9600 bps , Data bits: 8 , Stop bit: 1 , Parity bit: None
2 RS232 input frame format
There is only one byte in every input frame. The user could send different commands to the sensor for different purpose, the functions of command are shown in the following table.
HEX | 0X4F | 0X43 | 0X55 |
ASCII(Capital letter) | O | C | U |
Functions of command | Power On & Trigger Measuring | Continuous Measuring | Power Off |
3 RS232 output frame format
There is 6 bytes in every output frame, the frame header is 0XFF, MSB is A, LSB is E. Their orders are shown in this table here.
0XFF | A | B | C | D | E |
The mapping table of HEX and ASCII codes:
HEX | 0x30 | 0x31 | 0x32 | 0x33 | 0x34 | 0x35 | 0x36 | 0x37 | 0x38 | 0x39 | 0x2d | 0x20 | 0x00 |
ASCII | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | - | spacing |
|
Display Notices
All display notices are either displayed with “FF DA 00 XX XX XX”. The following errors can be corrected.
Display Notice | Cause | Correction |
FF DA 30 32 30 34 | Calculation error | Repeat procedure |
FF DA 30 32 35 32 | Temperature too high | Let device cool down |
FF DA 30 32 35 33 | Temperature too low | Warm device up |
FF DA 30 32 35 35 | Received signal too weak, time for a measurement too long. | Use a target plate |
FF DA 30 32 35 36 | Received signal too strong | Use target plate(gray side) |
FF DA 30 32 35 37 | Faulty measurement, too much background light | Use target plate(brown side) |
FF DA 30 32 35 38 | Outside of the range of measurement | Select measurement distance within the range of measurement |
Application case:
On what kind of targets can be measured?
All opaque targets can be measured. Reliable measurements on transparent targets are not possible.
How is the measurement rate influenced?
The measurement rate is influenced by the target. If the laser light is well reflected by the target, fast measurement rates can be achieved (up to 0.15s in tracking mode).
Does dust influence the measuring process?
If dust overcasts the main part of the laser beam, then your
measurement will be influenced in a negative way. However, this situation can only be found in extreme dusty environment like cement hopper etc.
Is it possible to measure to a moving target?
Yes it is possible. The measured distance is the mean value between the distance at start and end of the measuring process.
What is the Measuring Accuracy?
The measuring accuracy corresponds to the ISO-recommendation ISO/R 1938-1971 with a statistical confidence level of 95% (i.e. ±twice the standard deviation, refer to diagram right. The typical measuring accuracy relates to average conditions and is ±1.5mm for the DLS(H) 15 and ±3.0mm for the DLS(H) 30. This is valid for the tracking mode.
The maximum measuring error relates to unfavorable conditions such as:
- highly-reflecting surfaces (e.g. reflector tapes)
- operating at the limits of the permitted temperature range, adaptation to ambient temperature interrupted
- very bright ambient conditions, strong heat shimmer
The maximum measuring error can be up to ± 2 mm for the DLS(H) 15 and ± 5 mm for the DLS(H) 30.
The DLS-A devices do not compensate changes of the environment conditions. If the environment conditions differ from 20°C, 60% rel. humidity and 953mbar air pressure, the accuracy can be influenced if the measuring distances is longer as 150m.
The effects caused by environment condition are described in:
B.Edlen: “The Refractive Index of Air, Metrologia 2”, 71-80 (1966)
Is the Laser Light eye safe?
Class II lasers are low power (< 1mW), visible light lasers that could possibly cause damage to a person's eyes. Some examples of Class II laser uses are: classroom demonstrations, laser pointers, aiming devices and range finding equipment. If class II Laser beams are directly viewed for long periods of time (i.e. > 15 minutes) damage to the eyes could result. Avoid looking into a Class II Laser beam or pointing a Class II laser beam into another person's eyes. Avoid viewing Class II laser beams with telescopic devices. Realize that the bright light of a Class II Laser beam into your eyes will cause a normal reaction to look away or close your eyes. This response is expected to protect you from Class II Laser damage to the eyes.
Can I connect the DLS device to a Siemens PLC?
Yes, you can connect a DLS device with the RS422 interface to a Siemens S7 PLC. Please find a detailed example in the application section. (AN2010)
Contact Us
- Xi'an Foresight Electronics Technology Co., Ltd.
- Contact nameJack Lee Chat Now
- Phone86-29-87858986
- AddressRm. 11308, Floor 13, Unit 1, Bldg. 1, No. 9 Mansion, North Of Nanerhuan, East Of Yanta Road, Beilin Dist.
Product Categories
New Products
-
100m laser distance sensor for Height measuring
-
high measurment frequency and high accuracy 200m laser distance sensor/laser distance meter/laser rangefinder
-
road traffic control sensor with small size
-
150m laser distance sensor for length measurement
-
Diameter gauging 0.05-8m frequency 5-10hz measurment accuracy +/-1mm
-
High frequency 200Hz 905nm laser displacement sensor
-
Analog out laser distance meter
-
long distance laser distance sensor for Unmanned Aerial Vehicle
-
250m laser distance sensor wtih 4-20mA output
-
S176CR/S176LP Fusion splicer electrodes
-
Direct Ground Fault Finder non-metal grounding, loop grounding,grounding of the anode and cathode multi-point grounding
-
TYPE-39/81 Fusion splicer electrodes
-
AC Dummy load
-
480V 500KW/1000KW/2000KW AC Dummy load
-
220V 80Amps battery testing/battery load tester/battery discharger
-
220V 60Amps battery testing/battery load tester/battery discharger real capacity tester
-
220V 60Amps battery testing/battery load tester/battery discharger
-
battery conductance analyzer
-
5inch color touch screen battery impedance tester
-
battery impedance tester
-
battery capacity tester
-
lead acid and Nicd battery conductance testing/battery capacity tester/battery capacity analyzerAA
-
battery impedance tester resistance: 0.000ohm-99.999ohm 0.000v--25v
-
lead acid and Nicd battery conductance testing/battery capacity tester/battery capacity analyzer
Popular Searches
- measuring apparatus
- measuring instruments
- metering device
- Measuring Meter
- Dial Indicators
- digital caliper
- micrometer
- measuring tools
- vernier caliper
- dial caliper
- Dial Test Indicator
- Digital Dial Gauge Indicator
- Digital Dial Test Indicator
- Metric Dial Indicator
- Measuring Instrument
- digital vernier caliper
- Coating Thickness Gauge
- Laser Distance Meter
- measuring tool
- spirit level
- tape measure
- Height Measuring Instruments
- Measuring Tool Set
- Laser Spirit Level
- Level Measurement
- Laser Rangefinders
- range finder
- distance meter
- golf rangefinder
- hunting rangefinder
Recommended Products
- Laser Diameter Gauge,Laser Micrometer
- Laser Range Finder BH-VH
- SR2000 Eye-Safe Laser Rangefinder Module
- SR1200 Eye-Safe Laser Rangefinder Module
- laser range finder
- 40m 60m 80m 100m Laser Measure Rangefinder Laser Distance Meter
- 60m Laser Distance Meter Laser Rangefinder Measurer Meter Handheld Area/Volume Measure Tool
- 40M Laser Distance Meter with 5M Tape Measure
- 40M Laser Distance Meter with 5M Tape Measure
- Xiaomi HOTO Laser Tape Measure Smart Laser Rangefinder 30M OLED Display Laser Rangefinder
- xiaomi duka Laser Angle Casting Instrument real time angle meter LI 1 Double-sided high-definition led screen
- Xiaomi Mileseey DT10 Laser Tape Measure 2-in-1 Digital Laser Measure Laser Rangefinder with LCD Digital Display Magnetic Hook
Find Similar Products By Category
- Instruments & Meters > Optical Lens & Instrument > Rangefinder
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Jack Lee
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile