Home > Products > Flaw Detector > Portable Ultrasonic Phased Array Flaw Detector TM-2108P
Portable Ultrasonic Phased Array Flaw Detector TM-2108P
- Beijing Port
- Credit Card
You May Like
Product Details
Place of Origin | Beijing, China | Brand Name | TM-2108P | |
Model Number | TMTECK |
Product Description
Portable Ultrasonic Phased Array Flaw Detector TM-2108P
Portable Ultrasonic Phased Array Flaw Detector TM-2108P
TM-2108P Ultrasonic Flaw Detector is the Instrument newly developed by "TMTeck" as the first PA detector to reach 32:128 channel configuration. With water- & oil-proof panel and fan-free design, as well as easy and quick operation with all-course recording, It proves to be the most advanced and sophisticated portable phased array UT device in the country.
32:128 detection channels, 32-element focusing, available with max 64-element PA probe. With certain set paras, more channels engaged, better soundpath steering and imaging. 64 channels for large C-scan area coverage on workpiece, enhancing detection efficiency.
1ns precision of pulsing delay as the domestic highest; improving phase delay precision, significantly withhold side lobes and improving both longitudinal and lateral resolutions, resulting in higher imaging definition.
ALinearSectorC scan real-time fast imaging, supporting scan combos like A+L, A+L+C, A+S, A+S+C, and optional encoding or timebase while doing recording, with 100% original data acquision.
Support ACG and TCG curve compensation function ( unique in domestic market) that specified by ASME standard, support ACG automatic calibration function to combat uneven energy distribution in sector region and measurement error. Support ACG anto cal. Echo amplitude consistency is higher while employing ACG and TCG.
he sole fan-free and heat-relieving PA equipment in domestic market, fully-hermetical and water-dust proofing design of the casing, suitable for various hash conditions.
software operation, various modules like butt welding seam, T-type welding seam, composite materials, easy to operate and identify flaws.
based on beam angle and focal length, scan mode and element para can be created promptly, with anto optimization of the angle step of sector scan.
60dB analog gain, 36dB digital gain, 15MHz bandwidth, fliter of three shifts 0.5-9.7MHz,4.0-12.5MHz and 6.7-15MHz optional, anto OPT of pulse width acc. probe freq, demonstrating excellent capacities of noise-processing and image smoothing, enhancing imaging quality.
11-inch industrial-level, full WVGA resolution (800x600) TFT display, excellent display even outdoor or under strong sunlight.
Huge data storage for A/L/S/C scan image and anto creation of detection reports.
USB Port for fast data trans. HDMI port realizes infinite extension of the screen.
AC/DC power supply, and two Li-battery engagable, battery engagement shift acc. energy allowance, guaranteeing 6+ hours' work.
2108 operating without employment of ACG 2108 operating without employment of ACG
A-type test block shear-wave sector scan
A-type test block longitudinal-wave sector scan
Physical Parameters | |
Display | 11 inch 800×600 color TFT |
Probe Connector | I-PEX 160pin |
I/O Port | USB 2.0(HOST) |
HDMI | |
LAN 100M | |
Encoder Interface | |
TTL input/ouput | |
Memory | Capable:1GB + 4GB |
External: USB | |
Weight | 3kg(with Battery) |
Dimension | 290mm×195mm×105mm |
Mains | AC:100~240V 50Hz/60Hz |
Power Charging | Carry-on Charging or Spare Charging |
Battery Life | >7h |
Power | 25W |
Language | Chinese/English |
Temperature characteristics | Suitable Operation Temperature -20 ℃ ~ 50 ℃ |
Suitable Storage Temperature:-30℃~60℃ | |
Protection Rating | IP53 |
Pulser | |
PRF | Highest 9600Hz |
Voltage | adjustable bipolar square wave 40 ~100V , step 10V. |
Width | 30~500ns, step 5ns |
Damping | 50Ω |
Delay Precision | 0~10us Precision:1ns |
Receiver | |
Bandwidth | 0.5~15MHz |
Gain | 0.0~80.0dB |
Receiving Delay | 0~10us Precision: 1ns |
Filter | automatic adjustment |
Rectification | positive, negative, full-wave, RF |
Reject | 0~80% |
Channels | 32:128 |
Scan | |
Type | linear scan, sector scan, C scan |
Triggering | Time Base / encoder |
Scan line | Maximum 128 lines |
Scan angle | linear scan -45°~+45° |
sector scan -80°~+80°Step 0.5° | |
Calibration | |
Automatic calibration | velocity, probe zeroing |
Detection range | 0.0~1000mm (Longitudinal wave in steel) |
Display delay | 1000mm |
Unit | mm,inch |
Gate | |
Gates used to measure | A,B |
Boundry-purpose Gate | I(Optional) |
Gate start | full range |
Gate width | from the gate start to the full range |
Threshold | 5~95% |
Alarm | acoustic, optical |
Referential cursor | Two cursors for measurement, measure the level, vertical position and the distance between the cursors. |
measurement | |
DAC | Up to 20 points, 40dB dynamic range |
Measuring Mode | Front edge or Peak |
Indication | Gate Indicators: Am & SP |
Tri graphic analyses | |
0.5mm Measurement Resolution: 0.5mm | 0.5mm |
Surface Correction | available |
Auxiliary functions | on the basis of focal laws |
Probe Auxiliary | |
Packed-up | 4L16 4.0MHz16 ELE |