Home > Products > Security > Huwei optical network equipment Metro100 SDH PDH FE huawei optical transmission
Huwei optical network equipment Metro100 SDH PDH FE huawei optical transmission
- Shanghai
- T/T D/P D/A Credit Card
You May Like
-
Hillstone T3860 Intelligent Next-Generation firewall board with firewall hardware
-
Hillstone T3860 2U high firewall hardware
-
Hillstone E1600 UTM firewall appliance of firewall motherboard
-
Hillstone E1600 hardware firewall price of firewall appliance
-
China supplier of Hillstone E2300 security vpn server and firewall motherboard
-
Made in China Hillstone E2300 boundary wall security system
Product Details
Place of Origin | China | Brand Name | Huawei | |
Model Number | OptiX Metro100 |
Product Description
Product Positioning and Product Features
The OptiX Metro 100 is a type of STM-1 case-shaped equipment developed by Huawei Technologies Co., Ltd. (hereafter referred to as Huawei). The OptiX Metro 100 is mainly used at the access layer of transmission networks, with the features of high integration, flexible installation modes, and low power consumption.
Product Positioning
The OptiX Metro 100 is used at the access layer of a transmission network. The OptiX Metro 100 provides STM-1 optical interfaces and works with the other access-layer equipment to form an entire equipment group at the access layer of a transmission network, therefore constructing a complete OptiX product series of Huawei.
Product Features
The OptiX Metro 100 supports various services interfaces, power input modes, and installation modes, and a high security mechanism.
Various E1 Service Interfaces
The OptiX Metro 100 supports three types of physical interfaces:
- RJ-45 (120 ohms)
- BNC (75 ohms)
- DB15 (X.21)
High Network Security Mechanism
The OptiX Metro 100 supports the Radius security control, that is, the user names and passwords of all NEs are managed in a unified manner through the server of the user. Any user must pass the authentication before logging in to the NE. Therefore, the network security is high.
Support for Device Stack
The OptiX Metro 100 supports a maximum of 1+3 device stack (one master device and three slave devices), that is, 16xE1 services are configured into one optical channel.
Support for Default Settings
The OptiX Metro 100 is configured and maintained with the NMS and Web LCT, supporting the "one-click recovery to default settings" function.
Various Installation Modes
The OptiX Metro 100 can be installed in various ways. Therefore, you can select a proper installation mode according to the actual situation.
The OptiX Metro 100 supports the following installation modes:
- Cabinet-mounting (19-inch cabinet, ETSI 600 mm cabinet, or ETSI 300 mm open cabinet)
- Wall-mounting
- Desk-mounting
Various Power Input Modes
The OptiX Metro 100 supports the following power input modes:
- 110 V/220 V AC power input, the power input range is 90 V to 264 V, with the frequency in the range of 47 Hz to 63 Hz.
- -48 V/-60 V DC power input, the power input range is -38.4 V to -72 V.
The OptiX Metro 100 supports one AC power input and one DC power input at the same time. The two power inputs back up for each other. The AC power input is controlled by a switch, whereas the DC power input is not. When the AC power input and the DC power input are unavailable at the same time, the OptiX Metro 100 reports the VOLT_LOS alarm indicating a power failure.
Low Power Consumption, Natural Heat Dissipation, and High Integration
- Supports a maximum power consumption of 16 W only.
- Supports natural heat dissipation and produces low noise.
- Supports high integration.
Access capacity of the OptiX Metro 100
Service Type | Maximum Access Capacity Supported by One Device |
---|---|
SDH services | 2xSTM-1 (o) |
PDH services | 4xE1 |
Ethernet services | 2xFE (e) |
Protection Capability
The OptiX Metro 100 supports the equipment level protection and network level protection.
Equipment Level Protection
The OptiX Metro 100 supports the following equipment level protection schemes:
- Power supply protection
The AC power input and the DC power input back up for each other. When only either of the power inputs is available, the NE can continue to operate properly. When neither of the power inputs are unavailable, the device reports the VOLT_LOS alarm indicating a power failure.
- Anti-reverse protection
The power supply provides anti-reverse protection.
- Lightning-proof protection
The power supply provides protection against lightning attack, overcurrent, and short-circuit.
Network Level Protection
The OptiX Metro 100 supports the following network level protection schemes:
- 1+1 or 1:1 linear multiplex section protection (MSP)
- SNCP
DCN Features
The DCN feature is used when the OAM message of the OptiX Metro 100 needs to be transparently transmitted by the third-party equipment, or when the OptiX Metro 100 needs to transparently transmit the OAM message of the third-party equipment.
To exchange network management messages between the OptiX Metro 100 and the third-party equipment, the following modes can be adopted:
- Extended DCC bytes: The 4x(D1 to D3) bytes or 4x(D4 to D12) bytes can be used for embedded control channel (ECC) communication.
- Transport Protocol Class 4 (TP4), that is, OSI over DCC
- IP over DCC
- Simple Network Management Protocol (SNMP)
SDH Clock
The OptiX Metro 100 supports various synchronous Ethernet clock sources and clock management functions.
The OptiX Metro 100 supports the following clock functions:
- External clock source
- Line clock source
- Tributary clock source
- Internal clock source
- Tributary re-timing function
- One 2 Mbit/s phase-locked source
- Standard Synchronization Status Messaging (SSM) protocol
- Tracing mode, hold-over mode, and free-run mode
Overview
Logical boards on the OptiX Metro 100
Logical Board Name | Description | Valid Slots |
---|---|---|
PWM | DC/AC power supply board | Slot1 |
SCC | SCC board | Slot2 |
SFP | 2xSTM-1 line board | Slot3 |
XCSA | Cross-connect board | Slot4 |
STGA | Clock board | Slot5 |
EFT2 | FE service transparent transmission board
| Slot6 |
SPLS | 4xE1 tributary board
| Slot7 |
EXPD | Extended interface board
| Slot8 |
CAU | Power monitoring board | Slot15 |
Functions and features of the PDH unit
Functions and Features | Description |
---|---|
Basic function | Transmits and receives 4xE1 services. |
Alarm and performance event | Supports various alarms and performance events, which facilitates the management and maintenance of the equipment; supports the alarm reversion function. |
Clock source |
|
Maintenance features |
|
Overhead processing |
|
Other functions | Supports three types of E1 interfaces: RJ-45 (120 ohms), BNC (75 ohms), and DB15 (X.21). |
Functions and features of the SDH unit
Functions and Features | Description |
---|---|
Basic function | Transmits and receives 2xSTM-1 optical signals. |
Alarm and performance event | Supports various alarms and performance events, which facilitates the management and maintenance of the equipment; supports the alarm reversion function. |
Clock source | Supports the line clock extraction function. |
Maintenance features |
|
Overhead processing |
|
Optical module |
|
Size, weight, and power consumption of the OptiX Metro 100
Equipment Name | Maximum Power Consumption | Maximum Weight | Fuse Capacity | Dimensions |
---|---|---|---|---|
OptiX Metro 100 | 16 W | 2.9 kg | 1 A | 442 mm (W) x 220 mm (D) x 43.6 mm (H) |
Safety Certification
The safety design of the OptiX Metro 100 meets the requirements of CE authentication and complies with IEC60950, IEC60825-1/2, and IEC60417-Graphical Symbols for Use on Equipment. All safety critical components that the OptiX Metro 100 uses have UL/VDE certificates.
Climate requirements for storage environment
Item | Range |
---|---|
Altitude | ≤ 4000 m |
Pressure | 70-106 kPa |
Temperature | -40°C to +70°C |
Temperature change rate | ≤ 1 °C/min |
Relative humidity | 5%-100% |
Solar radiation | ≤ 1120 W/s2 |
Heat radiation | ≤600 W/s2 |
Wind speed | ≤ 30 m/s |
Climate requirements for transportation environment
Item | Range |
---|---|
Altitude | ≤ 4000 m |
Pressure | 70-106 kPa |
Temperature | -40°C to +70°C |
Temperature change rate | ≤ 1 °C/min |
Relative humidity | 5%-100% |
Solar radiation | ≤ 1120 W/s2 |
Heat radiation | ≤ 600 W/s2 |
Wind speed | ≤ 30 m/s |
Requirements for temperature and humidity
Working temperature | Relative humidity |
---|---|
Short-Term Operation: -5°C to +55°C | 5%-95% |
Long-Term Operation: 0°C to +45°C |
Contact Us
- Shanghai Chu Cheng Information Technology Co., Ltd.
- Contact nameicegreen guan Chat Now
- Phone86-21-58718070
- AddressRoom 110, No. 389, Jinwan Road
Product Categories
Access | Firewall | New Products | Optical Fiber Tools |
Routers | Security | server | Storage |
Switches | Transport Network | UC | VOIP |
Wireless Charger | WLAN |
New Products
-
Hillstone T-Series Intelligent Next-Generation Firewall Hardware SG-6000-T3860
-
Hillstone T-Series Firewall Hardware SG-6000-T3860
-
VPN Hillstone T-Series Security Firewall Hardware SG-6000-T3860
-
Hillstone Firewall Hardware Market China SG-6000-T5060
-
New Products ON China Market Hillstone Firewall Hardware SG-6000-T5060
-
Hillstone VPN Firewall Hardware SG-6000-T5060
-
Hillstone Security System Application-Aware Firewall Hardware SG-6000-T5060
-
Hillstone Security Next-Generation iMVP Firewall Hardware SG-6000-T5060
-
Hillstone Security Next-Generation iMVP Firewall Hardware SG-6000-T5860
-
Hillstone Security Application-Aware Firewall Hardware SG-6000-T5860
-
Hillstone Application-Aware Firewall Hardware SG-6000-T5860 Made in China
-
Hillstone New QoS VPN Firewall Hardware SG-6000-T5860
-
Hillstone X7180 Data Center Firewall SG-6000-X7180
-
Hillstone E Series Next-Generation Firewalls Appliance SG-6000-E1600
-
Hillstone E Series Firewalls Appliance SG-6000-E1600 Made IN China
-
Hillstone Security System E Series Firewalls Appliance SG-6000-E160
-
New Products ON China Market Hillstone E Series Firewall Appliance SG-6000-E160
-
Hillstone E-Series VPN Firewall Hardware SG-6000-E1600
-
Hillstone E-Series VPN Firewall Hardware SG-6000-E1700
-
Hillstone E-Series Security-System QoS Firewall Hardware SG-6000-E1700
-
Hillstone E-Series QoS Firewall Appliance SG-6000-E1700 Made in China
-
Hillstone Next-Generation iMVP VPN E-Series Firewall Appliance SG-6000-E1700
-
Hillstone Next-Generation iMVP VPN E-Series Firewall Appliance SG-6000-E2300
-
Hillstone iMVP Security System E-Series Firewall Appliance SG-6000-E2300
Popular Searches
- Optical Amplifier
- joint closure
- termination
- fiber optic
- ftth
- telecommunication
- video transceiver
- floor socket
- distribution box
- Fiber Optic Equipment
- fusion splicer
- optical fiber splicing machine
- fiber optic fusion splicer
- fiber optic adapter
- optical fiber fusion splicer
- machine fiber optic fusion
- fiber optic splicing kit
- fiber optic attenuator
- optical fusion splicer
- Fiber Optic Plc Splitter
- Fiber Optic Splice Closure
- Fiber Optic Test Equipment
- meter box
- Switch Cover
- Visual Fault Locator
- outdoor box
- Fiber Optic Modem
- optical transmitter
- Optical Multimeter
- Optical Terminal Ont Onu
Recommended Products
- Oven Protection Sleeve , Fiber Optic Heat Oven Sleeve
- 1x32 MEMS optical switch
- 1X24 MEMS Fiber Optical Switches
- 1X24 MEMS optical switch module -xionghua
- 1550nm 1X16 MEMS optical switch
- 1X16 MEMS optical switch module
- SM 1X4 MEMS optical switch
- 1310nm 1X4 MEMS optical switch module
- 1550nm 1X8 MEMS optical switch module
- MEMS 1x8 Fiber Optical Switch —xionghua
- DC-BLOCK DB-4310FM-6
- F/UTP Cat.6A Patch cord 23AWG 7*0.2 LSZH - 2m
Find Similar Products By Category
- Electrical & Electronics > Telecommunication & Broadcasting > Fiber Optic Equipment
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
icegreen guan
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile