single fan tray

Browse 11 global buying requests and sourcing opportunities.
  • We require transparent plastic trays with 3 compartments (1 large + 2 small) for hospital sterilization use. Specifications:
    - Heat-resistant material
    - Dimensions: 130mm(W) x 195mm(L)
    - Partition layout: 65mm + 135mm
    - Must be transparent color

    Quantity required: 3,000,000 pieces for single-use application. 

    Kuwait Kuwait
    Posted at: 2025-08-31 21:10:03
    ******
  • We are seeking complete food production machinery to achieve daily output of 30,000 ready meals (250-300g each) in single/dual/triple compartment trays. Required equipment specifications:

    1. Production Process Requirements:
    - Meat preparation: Thawing, cutting, portioning systems
    - Cooking & assembly: Automated meal component integration
    - Packaging: MAP/vacuum sealing solutions for multi-compartment trays
    - Post-processing: IQF/blast freezing or sterilization capabilities

    2. Key Equipment Features:
    - Minimum 30,000 meals/day capacity
    - Full/mostly automated operation
    - Suitable for mass production scale
    - Compatible with multiple tray configurations

    3. Commercial Terms:
    - Target delivery timeline: 30 days
    - No brand preference
    - Focus on quality/reliability for continuous operation

    Please provide technical specifications, MOQ, and commercial terms.

    Saudi Arabia Saudi Arabia
    Posted at: 2025-08-25 02:50:05
    G
    ******
  • Urgent Request for Quotation of Oil Extraction Machine(Mini) as per under specification. Qty: 100. We will participate in a tender so kindly send me the best price. The machine should be made of MS Plate, MS angle bar, MS flat bar, MS rod, MS sheet cast iron, ball bearing, pulley etc. The functional components of the machine will include a feeding tray, rotating casing, spiral screw, shaft, angle, etc. Overall Dimension: Minimum (L× W× H) mm 1350×640×1280. Power transmission: 60 cm pulley. Milling cylinder size: Diameter 200 mm, Length 550 mm. Size of hopper: 380×380×380 mm. Capacity: 18 - 20 kg/h. Oil extraction recovery: 30 - 35%. Engine: 15 - 16 hp diesel engine four - stroke, single - cylinder, and air - cooled. Weight: 240 - 250 kg (Without Engine). Number of Wheel: 03. Wheel diameter: Rubber (400 - 10) mm.

    Bangladesh Bangladesh
    Posted at: 2025-08-11 01:14:38
    ******
  • We are interested in purchasing 3 pcs of the A10 Single Fan Tray (ASK?FAN?010) for TH5430S. Please let us know the unit price, shipping cost to Ukraine, and estimated lead time. 3 pcs. Delivery by air

    Ukraine Ukraine
    Posted at: 2025-07-21 16:20:07
    ******
  • Original New A10 Single fan tray for TH5430S/6430/6430S ASK - FAN - 010. 3 pcs

    Russian Federation Russian Federation
    Posted at: 2025-06-24 21:00:05
    I
    ******
  • I am interested in a desktop oven for single and small-scale production. Main requirements: - it must be possible to add custom temperature profiles; - preferably convection (hot air fan) for uniform heating; - 110V power supply; - shipping to the USA.

    Ukraine Ukraine
    Posted at: 2025-05-28 03:00:05
    ******
  • I'm looking for A10 Single fan tray for TH5430S/6430/6430S.? Also ask about TH5440 - FAN and its price.

    Finland Finland
    Posted at: 2025-05-19 15:10:03
    ******
  • I'm looking for FAN modules for A10 -  TH6430-FAN TH5440-FAN THSK-FAN-060 THSK-FAN-010 THSK-FAN-020 THSK-FAN-435 ASK-FAN-010 ASK-FAN-020 ASK-FAN-060 ASK-FAN-435
    Can you help me?

    Germany Germany
    Posted at: 2025-03-10 17:20:02
    ******
  • Dear Sir/Madam, Kindly quote the price and availability of the following items. 1. EXCITATION TRANSFORMER Rating = 500KVA Continuous duty,11KV/265V, 50Hz with 5 tapping positions from 11.55kV to 10.45kV Insulation Class: F, Type: Three Phase two winding Converter transformer Resin insulation Dry type Model: ZSCB9-500/11 Standard: GB1094.11 IEC60076- 11, Certification: ISO9001 Certified Vector group= Yd11 Protection level: IP20 Rated current HV/LV: 26.2/1089A Type of cooling= AN/AF having cooling fans at each phase with temperature controller Rated Impedance =4.15%, Climatic Class: C2 Total mass: 2040kg, Environmental Class: E2, Fire behavior class: F1, Temp. Rise Limit: 80K Insulation level in kV (Line Terminal) HV side: LI/AC75/35 KV Insulation Level in kV (Line Terminal) LV side: LI/AC 0/3 KV 2. STATION SERVICE TRANSFORMER:       Type: Dry type, cast resin insulation Rating: 500KVA Continuous duty,11/0.4kV with 05 tapping positions (from 11.55kV to 10.45kV) ,50Hz. Model: SCB9-500/11, Standard: GB1094.11 IEC60076-11, Certification: ISO9001 Certified Operating condition: Indoor Cooling: AN/AF having cooling fans at each phase with temperature controller Thermal class: F class Rated Impedance: 3.88%, Vector group: Dyn11 Rated current primary side: 26.2A Rated current secondary side: 722A Temperature rise limit: 100K, Protection level: IP20, Total mass: 2090kg, Climatic Class: C2, Environmental Class: E2, Fire behavior class: F1 Insulation level in kV (Line Terminal) HV side: LI/AC75/35 Insulation Level in kV (Line Terminal) LV side: LI/AC 0/3   3. NEUTRAL GROUNDING TRANSFORMER Specifications Transformer Rating:11/0.5/0.11kV, 40KVA Single Phase Model: ZZD-11/1.367F, Certification: ISO9001 Certified, Rated voltage: 11/√3 kV, Rated frequency: 50Hz, Rated Current: 274A, Rated Time: 30 sec Resistance value: 1.367?, Weight: 1500kg

    Bangladesh Bangladesh
    Posted at: 2025-02-12 18:54:43
    ******
  • would like to have your offer for the supply of the following tender items with lead time and Data sheet. MPPT charge controller, efficiency not less than 92 %, and shall meet the following specifications. voltage, as per technical specifications Controller must utilize passive cooling (not fans); Should allow parallel operation, i.e more than one unit can be connected in parallel. Controllers to be certified CE or UL and to meet at least one for the following or equivalent standards IEC 62509 or IEC 62093; The device should have LED or LCD display. Equipped with SPD in the upstream input for each Charge Controller. Product warranty shall be 5 years. 228 Pcs MPPT Charge Controller Rated 85A - 100 A, at least 150 VDC input voltage. 148 Pcs MPPT Charge Controller Rated 100 A, at least 150VDC input voltage. 83 Pcs MPPT Charge Controller Rated 100 A, at least 450VDC input voltage. Off-Grid Inverter single phase, pure sine wave, 230 V, 50Hz as per below technical specifications. - The inverter shall produce pure sine wave form with provision for battery charger, and it can be configured individually or in parallel - Output frequency shall be 50 Hz - Designed for indoor enclosure not less than IP 20 - Maximum efficiency should be not less than 90 % at full load - To be certified to meet at least CE and UL marking and complaint with IEC 62109 - The device should be integrated with LED indicators or LCD display - It shall allow adjustment of battery voltage and charging current - The device shall allow connection to grid and/or backup generator(s) - The charging function of the inverter/charger shall include battery charging functionality   and the inverter shall be wired in ways that make use of the inverter battery charging   functionality if the installation includes either mains power or a diesel generator. - Protections required: AC overload and load short circuit, overvoltage, overheating and battery reverse polarity - The inverter shall allow internet connection for remote monitoring - Product warranty shall be 5 years. 22 Pcs 7KVA Solar Off-Grid Inverter. 69 Pcs 10KVA Solar Off-Grid Inverter. . 116 Pcs 15KVA Solar Off-Grid Inverter. 

    Pakistan Pakistan
    Posted at: 2025-01-20 22:19:32
    ******
  •  Please select a two-section fan cooling tower. The power of one section is 1276 kW. Water temperature at the entrance to the cooling tower is 30 C Water temperature at the outlet of the cooling tower is 25 C Outdoor air temperature according to wet thermometer 22 C The presence of a heated pan to prevent freezing. The design of the cooling tower must ensure operation in the mode: one section is working, the other is reserve and vice versa. The design of the cooling tower must ensure the ability of one section to operate completely with the shut-off valves drained off and drained from the reserve section SOW pipelines. The pool of sections must be separated by a partition so that one of the sections can be completely drained. Return water parameters: - pH - 8.64; - total hardness - 5.52 mEq/l; - concentration of petroleum products -0.39 mg/dm3; - chloride ion concentration - 22.0 mg/dm3; - concentration of suspended substances - 12.7 mg/dm3; The service life of all elements of the cooling tower, with the exception of the load-bearing frame, pan (bowl), pipelines, fan and enclosing structures, is at least 10 years. The service life of the load-bearing frame, tray (bowl), pipelines, fan and enclosing structures is at least 15 years. The equipment must be equipped with drives based on brushless (non-contact) or asynchronous motors. 

    Belarus Belarus
    Posted at: 2024-07-15 20:01:03
    ******